Clinical performance evaluation of a novel, automated chemiluminescent immunoassay, QUANTA Flash CTD Screen Plus

被引:0
|
作者
Chelsea Bentow
Gabriella Lakos
Rachel Rosenblum
Cassandra Bryant
Andrea Seaman
Michael Mahler
机构
[1] Inova Diagnostics,
[2] Inc.,undefined
来源
Immunologic Research | 2015年 / 61卷
关键词
Antinuclear antibodies; Chemiluminescent immunoassay; Indirect immunofluorescence; Solid phase assay; Connective tissue disease; Systemic autoimmune rheumatic disease;
D O I
暂无
中图分类号
学科分类号
摘要
The QUANTA Flash® CTD Screen Plus is a chemiluminescent immunoassay (CIA) for the detection of the major antinuclear antibodies (ANA) on the BIO-FLASH® platform. NOVA View® is an automated fluorescence microscope that acquires digital images of indirect immunofluorescent assay (IFA) slides. Our goal was to evaluate the clinical performance of the two automated systems and compare their performance to that of traditional IFA. Sera from patients with systemic autoimmune rheumatic diseases (SARD, n = 178), along with disease and healthy controls (n = 204), were tested with the CTD CIA and with NOVA Lite® HEp-2 ANA, using both the manual method of reading the IFA slides and the NOVA View instrument. The CTD CIA showed 78.1 % sensitivity for SARD, coupled with 94.1 % specificity. Manual IFA and NOVA View showed somewhat higher sensitivity (81.5 and 84.8 % in SARD, respectively), but significantly lower specificity (79.4 and 64.7 %, respectively). Both automated systems displayed somewhat different performance, due to the different principals of ANA detection: IFA with NOVA View digital image interpretation had higher sensitivity, while the CTD CIA showed higher specificity. With the added benefits of full automation, the new CTD CIA is an attractive alternative to traditional ANA screening.
引用
收藏
页码:110 / 116
页数:6
相关论文
共 50 条
  • [1] Clinical performance evaluation of a novel, automated chemiluminescent immunoassay, QUANTA Flash CTD Screen Plus
    Bentow, Chelsea
    Lakos, Gabriella
    Rosenblum, Rachel
    Bryant, Cassandra
    Seaman, Andrea
    Mahler, Michael
    IMMUNOLOGIC RESEARCH, 2015, 61 (1-2) : 110 - 116
  • [2] Clinical Performance of Two Automated Immunoassays, EliA CTD Screen and QUANTA Flash CTD Screen Plus, for Antinuclear Antibody Screening
    Yoon, Sumi
    Moon, Hee-Won
    Kim, Hanah
    Hur, Mina
    Yun, Yeo-Min
    ANNALS OF LABORATORY MEDICINE, 2022, 42 (01) : 63 - 70
  • [3] Comparison of QUANTA Flash® ASCA, a Novel Chemiluminescent Immunoassay, with Other Assays for the Detection of ASCA IgA and IgG
    Stinton, Laura
    Bentow, Chelsea
    Seaman, Andrea
    Mahler, Michael
    Lopez-Hoyos, Marcos
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2013, 108 : S522 - S523
  • [4] Clinical Comparison of QUANTA Flash dsDNA Chemiluminescent Immunoassay with Four Current Assays for the Detection of Anti-dsDNA Autoantibodies
    Infantino, Maria
    Meacci, Francesca
    Bentow, Chelsea
    Martis, Peter
    Benucci, Maurizio
    Afeltra, Antonella
    Rigon, Amelia
    Atzeni, Fabiola
    Sarzi-Puttini, Piercarlo
    Manfredi, Mariangela
    Mahler, Andmichael
    JOURNAL OF IMMUNOLOGY RESEARCH, 2015, 2015
  • [5] Improvement and multicenter evaluation of the analytical performance of an automated chemiluminescent immunoassay for alpha fetoprotein
    Morota, Kaori
    Komori, Makoto
    Fujinami, Ryo
    Yamada, Koji
    Kuribayashi, Kageaki
    Watanabe, Naoki
    Sokoll, Lori J.
    Elliott, Debra
    Chan, Daniel W.
    Martens, Frans
    Heijboer, Annemieke C.
    Blankenstein, Marinus A.
    Hershberger, Stefan J.
    Pfeiffer, Zachary A.
    Vaidya, Shyam V.
    Dowell, Barry L.
    INTERNATIONAL JOURNAL OF BIOLOGICAL MARKERS, 2012, 27 (01): : 39 - 46
  • [6] Clinical performance of a novel chemiluminescent enzyme immunoassay for FGF23
    Ito, Nobuaki
    Kubota, Takuo
    Kitanaka, Sachiko
    Fujiwara, Ikuma
    Adachi, Masanori
    Takeuchi, Yasuhiro
    Yamagami, Hitomi
    Kimura, Takehide
    Shinoda, Tatsuya
    Minagawa, Masanori
    Okazaki, Ryo
    Ozono, Keiichi
    Seino, Yoshiki
    Fukumoto, Seiji
    JOURNAL OF BONE AND MINERAL METABOLISM, 2021, 39 (06) : 1066 - 1075
  • [7] Analytical and clinical performance of a novel chemiluminescent microparticle immunoassay for detection of tryptase
    Tao, R.
    Braddock, B.
    Cruz-Campos, A.
    Sun, J.
    Garibay-Grande, J.
    Laderman, E.
    ALLERGY, 2023, 78 : 82 - 82
  • [8] Clinical performance of a novel chemiluminescent enzyme immunoassay for FGF23
    Nobuaki Ito
    Takuo Kubota
    Sachiko Kitanaka
    Ikuma Fujiwara
    Masanori Adachi
    Yasuhiro Takeuchi
    Hitomi Yamagami
    Takehide Kimura
    Tatsuya Shinoda
    Masanori Minagawa
    Ryo Okazaki
    Keiichi Ozono
    Yoshiki Seino
    Seiji Fukumoto
    Journal of Bone and Mineral Metabolism, 2021, 39 : 1066 - 1075
  • [9] Clinical performance evaluation of a novel rapid response chemiluminescent immunoassay for the detection of autoantibodies to extractable nuclear antigens
    Bentow, Chelsea
    Swart, Andreas
    Wu, Jason
    Seaman, Andrea
    Manfredi, Mariangela
    Infantino, Maria
    Benucci, Maurizio
    Lakos, Gabriella
    Mahler, Michael
    CLINICA CHIMICA ACTA, 2013, 424 : 141 - 147
  • [10] Evaluation of the Novel Methotrexate Architect Chemiluminescent Immunoassay: Clinical Impact on Pharmacokinetic Monitoring
    Aumente, Maria D.
    Lopez-Santamaria, Julia
    Concepcion Donoso-Rengifo, Maria
    Reyes-Torres, Inmaculada
    Montejano Hervas, Pablo
    THERAPEUTIC DRUG MONITORING, 2017, 39 (05) : 492 - 498