Improvement and multicenter evaluation of the analytical performance of an automated chemiluminescent immunoassay for alpha fetoprotein

被引:5
|
作者
Morota, Kaori [1 ]
Komori, Makoto [1 ]
Fujinami, Ryo [1 ]
Yamada, Koji [2 ]
Kuribayashi, Kageaki [2 ]
Watanabe, Naoki [2 ]
Sokoll, Lori J. [3 ]
Elliott, Debra [3 ]
Chan, Daniel W. [3 ]
Martens, Frans [4 ]
Heijboer, Annemieke C. [4 ]
Blankenstein, Marinus A. [4 ]
Hershberger, Stefan J. [5 ]
Pfeiffer, Zachary A. [5 ]
Vaidya, Shyam V. [5 ]
Dowell, Barry L. [5 ]
机构
[1] Abbott Japan Co Ltd, Res & Dev, Matsudo, Chiba 2702214, Japan
[2] Sapporo Med Univ, Sapporo, Hokkaido, Japan
[3] Johns Hopkins Univ, Div Clin Chem, Dept Pathol, Baltimore, MD USA
[4] Vrije Univ Amsterdam, Med Ctr, Amsterdam, Netherlands
[5] Abbott Labs, Div Diagnost, Abbott Pk, IL 60064 USA
来源
关键词
AFP; Chemiluminescent microparticle immunoassay; Hepatocellular carcinoma; Nonseminomatous testicular cancer; Prenatal testing; MEDICINE PRACTICE GUIDELINES; HEPATOCELLULAR-CARCINOMA; NATIONAL ACADEMY; TUMOR-MARKERS; ANTIBODIES; MANAGEMENT; DIAGNOSIS; THERAPY; CANCERS; JAPAN;
D O I
10.5301/JBM.2011.8738
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: A new ARCHITECT (R) alpha fetoprotein (AFP) assay was developed to improve the linearity at the upper end of the calibration curve and to enhance other performance characteristics. In addition, this reformulation eliminated the possibility of falsely depressed samples at high AFP concentrations. The purpose of this study was to evaluate its analytical performance at multiple sites. Methods: The assay configuration, the diluent formulation, and the manufacturing process were redesigned. Analytical performance was evaluated at Abbott Laboratories, Sapporo Medical University, VU University Medical Center, and Johns Hopkins University. Results: The limit of quantitation of the assay was 1.00-1.30 ng/mL. Total precision (%CV) across the assay range varied between 1.41 and 3.52. The assay was linear from 1.19 to 2535 ng/mL, and the range of the assay was expanded from 200 ng/mL to 2000 ng/mL. Comparison of this assay with the on-market ARCHITECT, AxSYM, ADVIA Centaur, DxI, AIA-1800, and E 170 systems yielded regression slopes of 0.91-1.08 and correlation coefficients of >= 0.99 for serum samples. No falsely depressed results were observed in 174 serum samples with AFP concentrations of 2018-1,196,856 ng/mL and in a spiked sample containing up to 10 mg/mL of purified AFP. Conclusions: The new AFP assay has improved an issue of the on-market ARCHITECT AFP assay and demonstrated excellent assay performance.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 50 条
  • [1] CHEMILUMINESCENT ENZYME-IMMUNOASSAY FOR ALPHA-FETOPROTEIN
    BRONSTEIN, I
    THORPE, GHG
    KRICKA, LJ
    EDWARDS, B
    VOYTA, JC
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1087 - 1088
  • [2] Multicenter Analytical Evaluation of the Automated Electrochemiluminescence Immunoassay for Cyclosporine
    Vogeser, Michael
    Shipkova, Maria
    Rigo-Bonnin, Rauel
    Wallemacq, Pierre
    Orth, Matthias
    Widmann, Monika
    Verstraete, Alain G.
    THERAPEUTIC DRUG MONITORING, 2014, 36 (05) : 640 - 650
  • [3] Development of an automated chemiluminescent immunoassay for cancer antigen 72-4 and the evaluation of its analytical performance
    Yanagihara, Fusamitsu
    Okura, Hideaki
    Ichikawa, Hisashi
    Shirakawa, Takuma
    Pan, You
    Tu, Bailin
    Lin, Zhihong
    Bonn, Ryan
    Kurella, Sridevi
    Schodin, Beth
    Yoshimura, Toru
    PRACTICAL LABORATORY MEDICINE, 2023, 34
  • [4] Development and analytical performance evaluation of an automated chemiluminescent immunoassay for pro-gastrin releasing peptide (ProGRP)
    Yoshimura, Toru
    Fujita, Kenju
    Kinukawa, Hideki
    Matsuoka, Yoshiharu
    Patil, Rahul D.
    Beligere, Gangamani S.
    Chan, Sabrina S.
    Dowell, Barry L.
    Sokoll, Lori
    Elliott, Debra
    Chan, Daniel W.
    Scheuer, Cornelia
    Hofmann, Karin
    Stieber, Petra
    Sakurai, Yousuke
    Iizuka, Masayuki
    Saegusa, Haruhisa
    Yamaguchi, Ken
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2009, 47 (12) : 1557 - 1563
  • [5] Multicenter analytical evaluation of an automated immunoassay for total plasma homocysteine
    Wu, AHB
    Holtman, V
    Apple, FS
    Ricchiuti, V
    DiBello, PM
    Jacobsen, D
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2000, 30 (02): : 185 - 190
  • [6] Performance evaluation and analytical characteristics of the Abbott AxSYM alpha-fetoprotein microparticle enzyme immunoassay.
    Toney, LJ
    Sharma, N
    Zibrat, SJ
    McLawhon, RW
    CLINICAL CHEMISTRY, 1996, 42 (06) : 389 - 389
  • [7] Performance evaluation of an automated immunoassay for the determination of AFP (alpha-fetoprotein) on the olympus AU3000i™ immunoassay system
    Roger, M. P.
    de Grimaudet de Rocheboueet, B.
    Cherasse, A.
    Cooney, D.
    Lentwojt, E.
    Fitzgerald, D.
    Gaston, S. J.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A107 - A107
  • [8] Performance evaluation of an automated immunoassay for the determination of AFP (alpha-fetoprotein) on the Olympus AU3000i™ immunoassay system
    Roger, M. P.
    de Rochebou, B. Grimaudet
    Cherasse, A.
    Lentwojt, E.
    Cooney, D.
    Fitzgerald, D.
    Gaston, S. J. S.
    TUMOR BIOLOGY, 2007, 28 : 114 - 114
  • [9] Hybritech total and free prostate-specific antigen assays developed for the Beckman Coulter access automated chemiluminescent immunoassay system: A multicenter evaluation of analytical performance
    Laffin, RJ
    Chan, DW
    Tanasijevic, MJ
    Fischer, GA
    Markus, W
    Miller, J
    Matarrese, P
    Sokoll, LJ
    Bruzek, DJ
    Eneman, J
    Nelson, J
    Bray, KR
    Huang, J
    Loveland, KG
    CLINICAL CHEMISTRY, 2001, 47 (01) : 129 - 132
  • [10] Development and evaluation of analytical performance of a fully automated chemiluminescent immunoassay for protein induced by vitamin K absence or antagonist II
    Fujita, Kenju
    Kinukawa, Hideki
    Ohno, Kenichi
    Ito, Yumiko
    Saegusa, Haruhisa
    Yoshimura, Toru
    CLINICAL BIOCHEMISTRY, 2015, 48 (18) : 1330 - 1336