Improvement and multicenter evaluation of the analytical performance of an automated chemiluminescent immunoassay for alpha fetoprotein

被引:5
|
作者
Morota, Kaori [1 ]
Komori, Makoto [1 ]
Fujinami, Ryo [1 ]
Yamada, Koji [2 ]
Kuribayashi, Kageaki [2 ]
Watanabe, Naoki [2 ]
Sokoll, Lori J. [3 ]
Elliott, Debra [3 ]
Chan, Daniel W. [3 ]
Martens, Frans [4 ]
Heijboer, Annemieke C. [4 ]
Blankenstein, Marinus A. [4 ]
Hershberger, Stefan J. [5 ]
Pfeiffer, Zachary A. [5 ]
Vaidya, Shyam V. [5 ]
Dowell, Barry L. [5 ]
机构
[1] Abbott Japan Co Ltd, Res & Dev, Matsudo, Chiba 2702214, Japan
[2] Sapporo Med Univ, Sapporo, Hokkaido, Japan
[3] Johns Hopkins Univ, Div Clin Chem, Dept Pathol, Baltimore, MD USA
[4] Vrije Univ Amsterdam, Med Ctr, Amsterdam, Netherlands
[5] Abbott Labs, Div Diagnost, Abbott Pk, IL 60064 USA
来源
关键词
AFP; Chemiluminescent microparticle immunoassay; Hepatocellular carcinoma; Nonseminomatous testicular cancer; Prenatal testing; MEDICINE PRACTICE GUIDELINES; HEPATOCELLULAR-CARCINOMA; NATIONAL ACADEMY; TUMOR-MARKERS; ANTIBODIES; MANAGEMENT; DIAGNOSIS; THERAPY; CANCERS; JAPAN;
D O I
10.5301/JBM.2011.8738
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: A new ARCHITECT (R) alpha fetoprotein (AFP) assay was developed to improve the linearity at the upper end of the calibration curve and to enhance other performance characteristics. In addition, this reformulation eliminated the possibility of falsely depressed samples at high AFP concentrations. The purpose of this study was to evaluate its analytical performance at multiple sites. Methods: The assay configuration, the diluent formulation, and the manufacturing process were redesigned. Analytical performance was evaluated at Abbott Laboratories, Sapporo Medical University, VU University Medical Center, and Johns Hopkins University. Results: The limit of quantitation of the assay was 1.00-1.30 ng/mL. Total precision (%CV) across the assay range varied between 1.41 and 3.52. The assay was linear from 1.19 to 2535 ng/mL, and the range of the assay was expanded from 200 ng/mL to 2000 ng/mL. Comparison of this assay with the on-market ARCHITECT, AxSYM, ADVIA Centaur, DxI, AIA-1800, and E 170 systems yielded regression slopes of 0.91-1.08 and correlation coefficients of >= 0.99 for serum samples. No falsely depressed results were observed in 174 serum samples with AFP concentrations of 2018-1,196,856 ng/mL and in a spiked sample containing up to 10 mg/mL of purified AFP. Conclusions: The new AFP assay has improved an issue of the on-market ARCHITECT AFP assay and demonstrated excellent assay performance.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 50 条
  • [21] Clinical performance evaluation of a novel, automated chemiluminescent immunoassay, QUANTA Flash CTD Screen Plus
    Chelsea Bentow
    Gabriella Lakos
    Rachel Rosenblum
    Cassandra Bryant
    Andrea Seaman
    Michael Mahler
    Immunologic Research, 2015, 61 : 110 - 116
  • [22] AN AUTOMATED ELECTROCHEMILUMINESCENCE IMMUNOASSAY FOR THE DETERMINATION OF ALPHA-1-FETOPROTEIN (AFP)
    PERKINS, S
    COLLINS, S
    KENTEN, E
    MCKEON, K
    MOSSNER, E
    SAUL, R
    CLINICAL CHEMISTRY, 1995, 41 (06) : S67 - S68
  • [23] Gold nanoparticles based chemiluminescent resonance energy transfer for immunoassay of alpha fetoprotein cancer marker
    Huang, Xiangyi
    Ren, Jicun
    ANALYTICA CHIMICA ACTA, 2011, 686 (1-2) : 115 - 120
  • [24] SERUM ALPHA-FETOPROTEIN .1. EVALUATION OF QUANTITATIVE ASSAYS ADAPTED TO AUTOMATED IMMUNOASSAY SYSTEMS
    GADSDEN, RH
    CATE, JC
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1991, 21 (04): : 246 - 253
  • [25] TECHNICON ALPHA-FETOPROTEIN - A FULLY AUTOMATED ENZYME-IMMUNOASSAY FOR THE DETERMINATION OF ALPHA-FETOPROTEIN IN HUMAN SERUM
    AYANOGLU, G
    GARRETT, D
    POURFARZANEH, M
    DELLAPUCA, R
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1058 - 1058
  • [26] Evaluation of an automated chemiluminescent immunoassay kit for antinuclear antibodies in autoimmune diseases
    Yaron Zafrir
    Boris Gilburd
    Marina Garcia Carrasco
    Shaye Kivity
    María Sánchez-Castañón
    Marcos López-Hoyos
    Mathilda Mandel
    Magdalena Szmyrka
    Yehuda Shoenfeld
    Nancy Agmon-Levin
    Immunologic Research, 2013, 56 : 451 - 456
  • [27] Evaluation of an automated chemiluminescent immunoassay kit for antinuclear antibodies in autoimmune diseases
    Zafrir, Yaron
    Gilburd, Boris
    Garcia Carrasco, Marina
    Kivity, Shaye
    Sanchez-Castanon, Maria
    Lopez-Hoyos, Marcos
    Mandel, Mathilda
    Szmyrka, Magdalena
    Shoenfeld, Yehuda
    Agmon-Levin, Nancy
    IMMUNOLOGIC RESEARCH, 2013, 56 (2-3) : 451 - 456
  • [28] Analytical and clinical performance of a novel chemiluminescent microparticle immunoassay for detection of tryptase
    Tao, R.
    Braddock, B.
    Cruz-Campos, A.
    Sun, J.
    Garibay-Grande, J.
    Laderman, E.
    ALLERGY, 2023, 78 : 82 - 82
  • [29] AN AUTOMATED FLUORESCENT ENZYME-IMMUNOASSAY FOR THE DETERMINATION OF HUMAN ALPHA-FETOPROTEIN
    BARNES, G
    DANNA, A
    MICELI, C
    MASSIE, D
    LOOS, V
    SHAW, N
    CLINICAL CHEMISTRY, 1987, 33 (06) : 919 - 919
  • [30] New automated chemiluminescent anti-heparin/PF4 immunoassay: analytical performance in hit suspected patients
    Faraudo, S.
    Martinez, A.
    Morcillo, S.
    Robert, F.
    Katerchi, A.
    Barry, R. G.
    Elalamy, I
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 888 - 888