Automated antinuclear immunofluorescence antibody analysis is a reliable approach in routine clinical laboratories

被引:11
|
作者
Zheng, Bing [1 ]
Li, Enling [1 ]
Zhu, Haoming [1 ]
Lu, Jingbo [1 ]
Shi, Xinming [1 ]
Zhang, Jie [1 ]
Li, Min [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Lab Med, Renji Hosp, Sch Med, 160 Pujian Rd, Shanghai 200127, Peoples R China
基金
中国国家自然科学基金;
关键词
antinuclear antibodies (ANAs); automation; indirect immunofluorescence; value-added ANA report; AUTOANTIBODIES; GUIDELINES; DIAGNOSIS; TESTS;
D O I
10.1515/cclm-2017-0050
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Indirect immunofluorescence (IIF) assays are recommended as the gold standard method for the detection of antinuclear antibodies (ANAs). This study aimed to investigate the reliability of an automated system. Methods: We compared 3745 serum samples using NOVA View archived images with manual analysis via microscopy. A custom cutoff value was established to distinguish ANA titers and was validated in two clinical laboratories. The automatic ANA pattern recognition system was evaluated, and all ANA-positive sera were subjected to two commercial ANA IIF kits to compare the consistency of the pattern interpretation results. For inconsistent patterns, a third ANA IIF testing kit was utilized. Results: Agreement of the interpretation of the ANA IIF test using the platform of NOVA View and manual microscopy was 96.9%. The local cutoff value to discriminate ANA titers in four main ANA patterns was calculated based on 1390 serum samples. In our laboratory, the titer prediction accuracy was superior to the preset cutoff in NOVA View (p < 0.01); the performance was similar in another laboratory (p = 0.11). The automatic pattern recognition accuracies of speckled, homogeneous, centromere, nucleolar and nuclear dot patterns were 62.7%, 57.4%, 92.6%, 30.5% and 27.3%, respectively. The consistency of the pattern interpretation results between INOVA and MBL kits was 95.3%. Conclusions: It is necessary to establish a custom value-added ANA report. However, confirmation of the digital immunofluorescence images by expert technicians was essential, and suspect results of an ANA pattern should be reconfirmed by another commercial ANA IIF kit to achieve more reliable results.
引用
收藏
页码:1922 / 1930
页数:9
相关论文
共 50 条
  • [31] Harmonization of Autoimmune Diagnostics with Antinuclear Antibody Testing Algorithm: Approach of Appropriateness and Clinical Relevance
    Melegari, Alessandra
    Bonaguri, Chiara
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2014, 16 (10): : 640 - 642
  • [32] Evaluation of the Risk of Laboratory Microbial Contamination during Routine Testing in Automated Clinical Chemistry and Microbiology Laboratories
    Farnsworth, Christopher W.
    Wallace, Meghan A.
    Liu, Albert
    Gronowski, Ann M.
    Burnham, Carey-Ann D.
    Yarbrough, Melanie L.
    CLINICAL CHEMISTRY, 2020, 66 (09) : 1190 - 1199
  • [33] A PRACTICAL CLINICAL APPROACH TO AUTOMATED ANALYSIS
    PETERS, HJ
    SOUTHERN MEDICAL JOURNAL, 1969, 62 (10) : 1281 - &
  • [34] The Reliability of a Novel Automated System for ANA Immunofluorescence Analysis in Daily Clinical Practice
    Alsuwaidi, Mohammed
    Dollinger, Margit
    Fleck, Martin
    Ehrenstein, Boris
    INTERNATIONAL JOURNAL OF RHEUMATOLOGY, 2016, 2016
  • [35] The Reliability Of a Novel Automated System For ANA Immunofluorescence Analysis In Daily Clinical Practice
    Alsuwaidi, Mohammed
    Dollinger, Margit
    Fleck, Martin
    Ehrenstein, Boris P.
    ARTHRITIS AND RHEUMATISM, 2013, 65 : S1084 - S1084
  • [36] Unifying NGS Workflows: A Modularized Automated Approach for Streamlining Clinical Molecular Diagnostics Laboratories
    Lucas, F. A. San
    Pelicano, H.
    Gascoyne, J.
    Mercado, J.
    Ninan, S.
    Ozenci, J.
    Duose, D.
    Yang, R.
    Routbort, M.
    Patel, K.
    Roy, S.
    Wistuba, I.
    Luthra, R.
    Medeiros, J.
    Alvarez, H.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2023, 25 (06): : S79 - S79
  • [37] Clinical Aspects of the Dense Fine Speckled Pattern in Indirect Immunofluorescence-Antinuclear Antibody Screening and Its Association with DFS70 Autoantibodies
    La Jeon, You
    Kang, So Young
    Lee, Woo-In
    Kim, Myeong Hee
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2019, 49 (04): : 496 - 502
  • [38] DO WE ALWAYS NEED SPECIFIC TEST FOR ANTI-RO/SSA ANTIBODIES IN ADDITION TO IMMUNOFLUORESCENCE METHOD FOR ANTINUCLEAR ANTIBODY ANALYSIS
    Bukilica, M. Sefik
    Kovacevic, L.
    Roganovic, N.
    Petrovic, D.
    Kadic, A.
    ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 : 887 - 887
  • [39] Automated Image Analysis for Determination of Antibody Titers Against Occupational Bacterial Antigens Using Indirect Immunofluorescence
    Brauner, Paul
    Jaeckel, Udo
    ANNALS OF OCCUPATIONAL HYGIENE, 2016, 60 (05): : 643 - 648
  • [40] Endogenous glucocorticoid analysis by liquid chromatography-tandem mass spectrometry in routine clinical laboratories
    Hawley, James M.
    Keevil, Brian G.
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2016, 162 : 27 - 40