Optical analysis of gel dosimeters: Comparison of Fricke and normoxic polymer gels

被引:4
|
作者
Gambarini, G.
Carrara, M.
Mariani, A.
Pirola, L.
Tomatis, S.
Valente, M.
Vanossi, E.
机构
[1] Univ Milan, Dept Phys, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, I-20133 Milan, Italy
[3] Politecn Milan, Dept Nucl Engn, Milan, Italy
[4] Natl Canc Inst, Dept Phys, Milan, Italy
关键词
dose imaging; Fricke gel; polymer gel; gel dosimetry; optical imaging; phantoms;
D O I
10.1016/j.nimb.2007.04.085
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The dosimetry method based on optical analysis of gel layers has been experienced utilising both Fricke and polymer (normoxic) gels. The aim of the work was that of investigating the potentiality of a normoxic polymer gel and of performing a further verification of the reliability of Fricke gel dosimeters. Optical absorbance was measured, both with a spectrophotometer and by imaging light transmittance detected with a CCD camera. The results of the study of sensitivity, linearity of the response and reproducibility of the polymer gel dosimeter have shown acceptable performances, except for doses below 2 Gy. The linearity range extends up to 20 Gy. On the other side, dose images and profiles have shown noticeable differences when compared to those calculated or measured with ionisation chambers or Fricke gel dosimeters. Such Fricke dosimeters have given further confirmation of their reliability. (C) 2007 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:191 / 195
页数:5
相关论文
共 50 条
  • [41] Characterization of PVA-GTA Fricke gels dosimeters using MRI and optical techniques in X-rays external radiation therapy
    Gallo, S.
    Arosio, P.
    Locarno, S.
    Orsini, F.
    Brambilla, M. G.
    Gambarini, G.
    Lizio, D.
    Monti, A. F.
    Torresin, A.
    Lenardi, C.
    Veronese, I.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2021, 44 (4-5):
  • [42] MAGIC - Normoxic polymer gel dosimetry in radiosurgery
    Scheib, SG
    Vogelsanger, W
    RADIOSUGERY, VOL 5, 2004, 5 : 213 - 224
  • [43] Characterization of ferric ions diffusion in Fricke gel dosimeters by using inverse problem techniques
    Vedelago, J.
    Quiroga, A.
    Valente, M.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (10): : 845 - 854
  • [44] Dose sensitivity modification in polymer gel dosimeters improves the accuracy of optical CT scanning for gel dosimetry
    Maryanski, MJ
    Xu, Y
    Wuu, CS
    MEDICAL PHYSICS, 2003, 30 (06) : 1478 - 1478
  • [45] A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic x-ray CT scanners
    Hill, B
    Venning, AJ
    Baldock, C
    MEDICAL PHYSICS, 2005, 32 (06) : 1589 - 1597
  • [46] Polymer gel dosimeters with PVA–GA matrix
    Seyed Mohammad Mahdi Abtahi
    Hamid Sadeghi Abandansari
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 651 - 658
  • [47] Radiation-induced refraction artifacts in the optical CT readout of polymer gel dosimeters
    Campbell, Warren G.
    Wells, Derek M.
    Jirasek, Andrew
    MEDICAL PHYSICS, 2014, 41 (11)
  • [48] Radiation-induced refraction artefacts in the optical CT readout of polymer gel dosimeters
    Campbell, Warren G.
    Jirasek, Andrew
    Wells, Derek M.
    MEDICAL PHYSICS, 2014, 41 (08) : 26 - 26
  • [49] A method for obtaining three-dimensional measurements of HDR brachytherapy dose distributions using Fricke gel dosimeters and optical computed tomography
    Andre Asena
    Sanna Nilsson
    Shaun T. Smith
    Tanya Kairn
    Scott B. Crowe
    Jamie V. Trapp
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 221 - 226
  • [50] Verification of IMRT using normoxic polymer gel (THP-gel)
    Hysing, LB
    Wasbo, E
    Gustavsson, H
    Karlsson, A
    Andersen, E
    Ersland, L
    Muren, L
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S183 - S184