dose imaging; Fricke gel; polymer gel; gel dosimetry; optical imaging; phantoms;
D O I
10.1016/j.nimb.2007.04.085
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The dosimetry method based on optical analysis of gel layers has been experienced utilising both Fricke and polymer (normoxic) gels. The aim of the work was that of investigating the potentiality of a normoxic polymer gel and of performing a further verification of the reliability of Fricke gel dosimeters. Optical absorbance was measured, both with a spectrophotometer and by imaging light transmittance detected with a CCD camera. The results of the study of sensitivity, linearity of the response and reproducibility of the polymer gel dosimeter have shown acceptable performances, except for doses below 2 Gy. The linearity range extends up to 20 Gy. On the other side, dose images and profiles have shown noticeable differences when compared to those calculated or measured with ionisation chambers or Fricke gel dosimeters. Such Fricke dosimeters have given further confirmation of their reliability. (C) 2007 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:191 / 195
页数:5
相关论文
共 50 条
  • [31] Ultrasonic absorption in polymer gel dosimeters
    Mather, ML
    Collings, AF
    Bajenov, N
    Whittaker, AK
    Baldock, C
    ULTRASONICS, 2003, 41 (07) : 551 - 559
  • [32] Response modification in polymer gel dosimeters
    Maryanski, M
    MEDICAL PHYSICS, 2002, 29 (06) : 1209 - 1209
  • [33] Ultrasound evaluation of polymer gel dosimeters
    Mather, ML
    Whittaker, AK
    Baldock, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09): : 1449 - 1458
  • [34] Analysis of the Dosimetric Characteristics of Normoxic Polymer Gel by Magnetic Resonance Images
    Cho, Sam Ju
    Shim, Su Jung
    Kim, Chul Yong
    Yang, Dae Sik
    Park, Young Je
    Lee, Suk
    Lee, Sang Hoon
    Lim, Sangwook
    Cho, Kwang Hwan
    Choi, Jin Ho
    Lee, Rena
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 56 (03) : 874 - 879
  • [35] A comparison of the dose-response behavior of AQUAJOINT®-based polymer gel and PAGAT gel dosimeters measured using Optical CT and MRI
    Takanashi, Takaoki
    Kawamura, Hiraku
    Fukasaku, Kazuaki
    Sahade, Daniel Antonio
    Hamada, Toshimasa
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [36] Characterization of the essential dosimetric properties of cosolvent-free polymer gel dosimeters: Recent progress in x-ray CT based normoxic polymer gel dosimetry
    Johnston, H.
    Hilts, M.
    Carrick, J.
    Jirasek, A.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [37] Sensitivity calibration procedures in optical-CT scanning of polymer gel dosimeters
    Xu, Y
    Wuu, C
    Maryanski, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1833 - 1833
  • [38] Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters
    Manjappa, Rakesh
    Makki, Sharath S.
    Kumar, Rajesh
    Kanhirodan, Rajan
    MEDICAL PHYSICS, 2015, 42 (02) : 750 - 759
  • [39] Characterization of a commercial optical CT scanner for imaging BANG® polymer gel dosimeters
    Islam, K
    Dempsey, J
    Maryanski, M
    Ranade, M
    Sohn, J
    Low, D
    MEDICAL PHYSICS, 2002, 29 (06) : 1371 - 1371
  • [40] Study of light transmittance from layers of Fricke-xylenol-orange-gel dosimeters
    Gambarini, G
    Birattari, C
    Mariani, M
    Marchesini, R
    Pirola, L
    Prestini, P
    Sella, M
    Tomatis, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 321 - 324