Polymer gel dosimeters with PVA–GA matrix

被引:0
|
作者
Seyed Mohammad Mahdi Abtahi
Hamid Sadeghi Abandansari
机构
[1] Imam Khomeini International University,Department of Physics
[2] Royan Institute for Stem cell Biology and Technology,Department of cell Engineering, Cell Sience Research Center
关键词
Polymer gel dosimeter; PVABAT; Polyvinyl alcohol; Radiation dosimetry; MRI;
D O I
暂无
中图分类号
学科分类号
摘要
Properties of a new polymer gel with cross-linked polyvinyl alcohol as a gelatinous matrix were investigated. The new polymer gel dosimeter was named PVABAT. The irradiation was performed using a calibrated 60Co beam. The dose responses of the PVABAT formulations were quantified with MRI transverse relaxation rate (R2) measurements. The results show that the PVABAT gel responds linearly to the absorbed dose for doses from 30 up to 45 Gy. The maximal amount of DΔ95%\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\text{D}}_{\Delta }^{{95{{\% }}}}$$\end{document} of PVABAT polymer gel dosimeter was about 0.19 Gy which was indicated on a better resolution in comparison with previously reported acrylamide-based polymer gel dosimeters formulations. Furthermore, the gel response remains stable in the investigated time (192 h) after the irradiation. The effective atomic number and electron density of the new gel showed a maximum difference of 3.2 and 2% with soft tissue respectively. The melting point also increased significantly for new formulation. Furthermore, the new gel formulation has an elemental tissue equivalency for dosimetry applications involving nuclear reactions.
引用
收藏
页码:651 / 658
页数:7
相关论文
共 50 条
  • [1] Polymer gel dosimeters with PVA-GA matrix
    Abtahi, Seyed Mohammad Mahdi
    Abandansari, Hamid Sadeghi
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (03) : 651 - 658
  • [2] Water equivalence of polymer gel dosimeters
    Sellakumar, P.
    Jebaseelan Samuel, E. James
    Supe, Sanjay S.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2007, 76 (07) : 1108 - 1115
  • [3] Ultrasonic absorption in polymer gel dosimeters
    Mather, ML
    Collings, AF
    Bajenov, N
    Whittaker, AK
    Baldock, C
    [J]. ULTRASONICS, 2003, 41 (07) : 551 - 559
  • [4] Ultrasound evaluation of polymer gel dosimeters
    Mather, ML
    Whittaker, AK
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09): : 1449 - 1458
  • [5] Response modification in polymer gel dosimeters
    Maryanski, M
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1209 - 1209
  • [6] New polymer gel dosimeters consisting of less toxic monomers with radiation-crosslinked gel matrix
    Hiroki, A.
    Yamashita, S.
    Sato, Y.
    Nagasawa, N.
    Taguchi, M.
    [J]. 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [7] Radiological properties of normoxic polymer gel dosimeters
    Venning, AJ
    Nitschke, KN
    Keall, PJ
    Baldock, C
    [J]. MEDICAL PHYSICS, 2005, 32 (04) : 1047 - 1053
  • [8] Effect of inorganic salts and matrix crosslinking on the dose response of polymer gel dosimeters based on acrylamide
    Chacon, David
    Strumia, Miriam
    Valente, Mauro
    Mattea, Facundo
    [J]. RADIATION MEASUREMENTS, 2018, 117 : 7 - 18
  • [9] Enhancement in dose sensitivity of polymer gel dosimeters composed of radiation-crosslinked gel matrix and less toxic monomers
    Hiroki, A.
    Yamashita, S.
    Taguchi, M.
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [10] Polymer Gel Dosimeters for use in Targeted Radionuclide Therapy
    Gear, J. I.
    Flux, G. D.
    Partridge, M.
    Ott, R. J.
    Charles-Edwards, E.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S207 - S207