A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic x-ray CT scanners

被引:45
|
作者
Hill, B
Venning, AJ
Baldock, C
机构
[1] Canberra Hosp, Biomed Engn Serv, Med Phys Sect, Woden, ACT 2606, Australia
[2] Univ Sydney, Inst Med Phys, Woden, ACT 2606, Australia
[3] Queensland Univ Technol, Sch Phys & Chem Sci, Brisbane, Qld 4001, Australia
[4] Univ Sydney, Sch Phys, Inst Med Phys, Sydney, NSW 2006, Australia
关键词
computer tomography; normoxic polymer gel dosimetry; dosimeter; CT; MRI; doseprofile;
D O I
10.1118/1.1925181
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computer tomography dose index (CTDI) is a measurement undertaken during acceptance testing and subsequent quality assurance measurements of diagnostic x-ray CT scanners for the determination of patient dose. Normoxic polymer gel dosimeters have been used for the first time to measure dose and subsequently CTDI during acceptance testing of a CT scanner and compared with the conventional ionization chamber measurement for a range of imaging protocols. The normoxic polymer gel dosimeter was additionally used to simultaneously determine slice-width dose profiles and CTDI in the transaxial plane, the measurements of which are usually determined with thermoluminescent dosimetry or film. The resulting CTDI for all slice widths calculated from the normoxic polymer gel dosimeter were within corresponding ionization chamber CTDI values. Slice-width dose-profiles full-width half-maximum values from the normoxic polymer gel dosimeter were compared to the slice sensitivity profiles and were within the tolerances of the manufacturer. Normoxic polymer gel dosimeters have been shown to be a useful device for determining CTDI and dose distributions for CT equipment, and provide additional information not possible with just the use of an ionization chamber. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1589 / 1597
页数:9
相关论文
共 50 条
  • [1] The effect of x-ray CT dose on normoxic polymer gel dosimeters
    Baxter, P.
    Jirasek, A.
    Hilts, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S56 - S56
  • [2] The dose response of normoxic polymer gel dosimeters measured using X-ray CT
    Hill, B
    Venning, A
    Baldock, C
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (931): : 623 - 630
  • [3] A Novel Application of MRI-Polymer Gel Dosimeter for Measurement of CTDI on X-Ray 64 Slices CT Scanner
    Karimiafshar, L.
    Alam, N. Riyahi
    Ay, M. R.
    Alahverdi, M.
    Pourfallah, T. Alahvirdi
    Hashemi, H.
    Farahani, A.
    Rafiei, B.
    Bakhtiary, M.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 541 - 544
  • [4] A Novel Application of MRI-Polymer Gel Dosimeter for Measurement of CTDI On X-Ray 64 Slices CT Scanner
    Riyahi-Alam, N.
    Karimiafshar, L.
    Ay, M.
    Pourfallah, T. Alahvirdi
    Allahverdi, M.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [5] Optimization of the imaging protocol of an X-ray CT scanner for evaluation of normoxic polymer gel dosimeters
    Subramanian, Brindha
    Ravindran, Paul B.
    Baldock, Clive
    [J]. JOURNAL OF MEDICAL PHYSICS, 2006, 31 (02) : 72 - 77
  • [6] Optical Evaluation of normoxic PAGAT polymer gel dosimeters used to measure SWDP on diagnostic CT scanners
    Sarabipour, Sarvenaz
    Bosi, Stephen
    Hill, Brendan
    Baldock, Clive
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1606 - 1608
  • [7] Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetry
    Jirasek, A.
    Hilts, M.
    McAuley, K. B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18): : 5269 - 5281
  • [8] Characterization of the essential dosimetric properties of cosolvent-free polymer gel dosimeters: Recent progress in x-ray CT based normoxic polymer gel dosimetry
    Johnston, H.
    Hilts, M.
    Carrick, J.
    Jirasek, A.
    [J]. 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [9] X-ray CT dose in normoxic polyacrylamide gel dosimetry
    Baxter, P.
    Jirasek, A.
    Hilts, M.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 1934 - 1943
  • [10] Dose rate properties of NIPAM-based x-ray CT polymer gel dosimeters
    Jirasek, A.
    Johnston, H.
    Hilts, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (11): : 4399 - 4411