Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans

被引:144
|
作者
Symons, Rolf [1 ]
Pourmorteza, Amir [1 ]
Sandfort, Veit [1 ]
Ahlman, Mark A. [1 ]
Cropper, Tracy [1 ]
Mallek, Marissa [1 ]
Kappler, Steffen [2 ]
Ulzheimer, Stefan [2 ]
Mahesh, Mahadevappa [3 ]
Jones, Elizabeth C. [1 ]
Malayeri, Ashkan A. [1 ]
Folio, Les R. [1 ]
Bluemke, David A. [1 ]
机构
[1] NIH, Dept Radiol & Imaging Sci, Clin Ctr, 10 Ctr Dr, Bethesda, MD 20892 USA
[2] Siemens Healthcare, Forchheim, Germany
[3] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
基金
美国国家卫生研究院;
关键词
LUNG-CANCER; IMAGE NOISE; PERFORMANCE; ARTIFACTS; SOCIETY; QUALITY; IMPACT; MODEL;
D O I
10.1148/radiol.2017162587
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate whether photon-counting detector (PCD) technology can improve dose-reduced chest computed tomography (CT) image quality compared with that attained with conventional energy-integrating detector (EID) technology in vivo. Materials and Methods: This was a HIPAA-compliant institutional review board-approved study, with informed consent from patients. Dose-reduced spiral unenhanced lung EID and PCD CT examinations were performed in 30 asymptomatic volunteers in accordance with manufacturer-recommended guidelines for CT lung cancer screening (120-kVp tube voltage, 20-mAs reference tube current-time product for both detectors). Quantitative analysis of images included measurement of mean attenuation, noise power spectrum (NPS), and lung nodule contrast-to-noise ratio (CNR). Images were qualitatively analyzed by three radiologists blinded to detector type. Reproducibility was assessed with the intraclass correlation coefficient (ICC). McNemar, paired t, and Wilcoxon signed-rank tests were used to compare image quality. Results: Thirty study subjects were evaluated (mean age, 55.0 years +/- 8.7 [ standard deviation]; 14 men). Of these patients, 10 had a normal body mass index (BMI) (BMI range, 18.5-24.9 kg/m(2); group 1), 10 were overweight (BMI range, 25.0-29.9 kg/m(2); group 2), and 10 were obese (BMI. 30.0 kg/m(2), group 3). PCD diagnostic quality was higher than EID diagnostic quality (P = .016, P = .016, and P = .013 for readers 1, 2, and 3, respectively), with significantly better NPS and image quality scores for lung, soft tissue, and bone and with fewer beam-hardening artifacts (P < .001). Image noise was significantly lower for PCD images in all BMI groups (P < .001 for groups 1 and 3, P < .01 for group 2), with higher CNR for lung nodule detection (12.1 +/- 6 1.7 vs 10.0 +/- 6 1.8, P < .001). Inter-and intrareader reproducibility were good (all ICC > 0.800). Conclusion: Initial human experience with dose-reduced PCD chest CT demonstrated lower image noise compared with conventional EID CT, with better diagnostic quality and lung nodule CNR.
引用
收藏
页码:980 / 989
页数:10
相关论文
共 50 条
  • [1] Photon-counting CT: Review of initial clinical results
    van der Bie, Judith
    van Straten, Marcel
    Booij, Ronald
    Bos, Daniel
    Dijkshoorn, Marcel L.
    Hirsch, Alexander
    Sharma, Simran P.
    Oei, Edwin H. G.
    Budde, Ricardo P. J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 163
  • [2] Clinical CT Applications with Photon-Counting Detectors
    Levinson, R.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [3] Silicon photomultiplier-based scintillation detectors for photon-counting CT: A feasibility study
    van der Sar, Stefan J.
    Brunner, Stefan E.
    Schaart, Dennis R.
    MEDICAL PHYSICS, 2021, 48 (10) : 6324 - 6338
  • [4] Deep Grid Inpainting for Photon-Counting CT Detectors
    Magonov, Jan
    Maier, Joscha
    Fournie, Eric
    Sunnegardh, Johan
    Stierstorfer, Karl
    Kachelriess, Marc
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [5] Photon-counting x-ray detectors for CT
    Danielsson, Mats
    Persson, Mats
    Sjolin, Martin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03):
  • [6] Compton Coincidence in Silicon Photon-Counting CT Detectors
    Sundberg, Christel
    Danielsson, Mats
    Persson, Mats
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [7] Compton coincidence in silicon photon-counting CT detectors
    Sundberg, Christel
    Danielsson, Mats
    Persson, Mats
    JOURNAL OF MEDICAL IMAGING, 2022, 9 (01)
  • [8] Spectral Photon-Counting CT Technology in Chest Imaging
    Si-Mohamed, Salim Aymeric
    Miailhes, Jade
    Rodesch, Pierre-Antoine
    Boccalini, Sara
    Lacombe, Hugo
    Leitman, Valerie
    Cottin, Vincent
    Boussel, Loic
    Douek, Philippe
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
  • [9] Low-dose lung cancer screening with photon-counting CT: a feasibility study
    Symons, Rolf
    Cork, Tyler E.
    Sahbaee, Pooyan
    Fuld, Matthew K.
    Kappler, Steffen
    Folio, Les R.
    Bluemke, David A.
    Pourmorteza, Amir
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01): : 202 - 213
  • [10] Accuracy Assessment of Photon-Counting CT for Dose Calculation in Photon Therapy
    Wu, X.
    Shah, J.
    Wohlfahrt, P.
    Wu, Q.
    Wu, Q. J.
    Sheng, Y.
    MEDICAL PHYSICS, 2024, 51 (10) : 7669 - 7669