Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans

被引:144
|
作者
Symons, Rolf [1 ]
Pourmorteza, Amir [1 ]
Sandfort, Veit [1 ]
Ahlman, Mark A. [1 ]
Cropper, Tracy [1 ]
Mallek, Marissa [1 ]
Kappler, Steffen [2 ]
Ulzheimer, Stefan [2 ]
Mahesh, Mahadevappa [3 ]
Jones, Elizabeth C. [1 ]
Malayeri, Ashkan A. [1 ]
Folio, Les R. [1 ]
Bluemke, David A. [1 ]
机构
[1] NIH, Dept Radiol & Imaging Sci, Clin Ctr, 10 Ctr Dr, Bethesda, MD 20892 USA
[2] Siemens Healthcare, Forchheim, Germany
[3] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
基金
美国国家卫生研究院;
关键词
LUNG-CANCER; IMAGE NOISE; PERFORMANCE; ARTIFACTS; SOCIETY; QUALITY; IMPACT; MODEL;
D O I
10.1148/radiol.2017162587
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate whether photon-counting detector (PCD) technology can improve dose-reduced chest computed tomography (CT) image quality compared with that attained with conventional energy-integrating detector (EID) technology in vivo. Materials and Methods: This was a HIPAA-compliant institutional review board-approved study, with informed consent from patients. Dose-reduced spiral unenhanced lung EID and PCD CT examinations were performed in 30 asymptomatic volunteers in accordance with manufacturer-recommended guidelines for CT lung cancer screening (120-kVp tube voltage, 20-mAs reference tube current-time product for both detectors). Quantitative analysis of images included measurement of mean attenuation, noise power spectrum (NPS), and lung nodule contrast-to-noise ratio (CNR). Images were qualitatively analyzed by three radiologists blinded to detector type. Reproducibility was assessed with the intraclass correlation coefficient (ICC). McNemar, paired t, and Wilcoxon signed-rank tests were used to compare image quality. Results: Thirty study subjects were evaluated (mean age, 55.0 years +/- 8.7 [ standard deviation]; 14 men). Of these patients, 10 had a normal body mass index (BMI) (BMI range, 18.5-24.9 kg/m(2); group 1), 10 were overweight (BMI range, 25.0-29.9 kg/m(2); group 2), and 10 were obese (BMI. 30.0 kg/m(2), group 3). PCD diagnostic quality was higher than EID diagnostic quality (P = .016, P = .016, and P = .013 for readers 1, 2, and 3, respectively), with significantly better NPS and image quality scores for lung, soft tissue, and bone and with fewer beam-hardening artifacts (P < .001). Image noise was significantly lower for PCD images in all BMI groups (P < .001 for groups 1 and 3, P < .01 for group 2), with higher CNR for lung nodule detection (12.1 +/- 6 1.7 vs 10.0 +/- 6 1.8, P < .001). Inter-and intrareader reproducibility were good (all ICC > 0.800). Conclusion: Initial human experience with dose-reduced PCD chest CT demonstrated lower image noise compared with conventional EID CT, with better diagnostic quality and lung nodule CNR.
引用
收藏
页码:980 / 989
页数:10
相关论文
共 50 条
  • [21] A generic model of semiconductor-based photon-counting detectors for spectral CT
    Bhattarai, Mridul
    Panta, Raj Kumar
    Clark, Darin
    Segars, W. Paul
    Abadi, Ehsan
    Samei, Ehsan
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [22] Silicon microchannel plates: Initial results for photon counting detectors
    Siegmund, OHW
    Tremsin, AS
    Vallerga, JV
    Beetz, CP
    Boerstler, RW
    Winn, D
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 : 188 - 198
  • [23] Coronary CT Angiography with Photon-counting CT: First-In-Human Results
    Si-Mohamed, Salim A.
    Boccalini, Sara
    Lacombe, Hugo
    Diaw, Adja
    Varasteh, Mohammad
    Rodesch, Pierre-Antoine
    Dessouky, Riham
    Villien, Marjorie
    Tatard-Leitman, Valerie
    Bochaton, Thomas
    Coulon, Philippe
    Yagil, Yoad
    Lahoud, Elias
    Erhard, Klaus
    Riche, Benjamin
    Bonnefoy, Eric
    Rioufol, Gilles
    Finet, Gerard
    Bergerot, Cyrille
    Boussel, Loic
    Greffier, Joel
    Douek, Philippe C.
    RADIOLOGY, 2022, 303 (02)
  • [24] Dental imaging in clinical photon-counting CT at a quarter of DVT dose
    Sawall, Stefan
    Maier, Joscha
    Sen, Sinan
    Gehrig, Holger
    Kim, Ti -Sun
    Schlemmer, Heinz -Peter
    Schoenberg, Stefan O.
    Kachelriess, Marc
    Ruetters, Maurice
    JOURNAL OF DENTISTRY, 2024, 142
  • [25] Comparison of Low Dose Performance of Photon-Counting and Energy Integrating CT
    Rajagopal, Jayasai R.
    Farhadi, Faraz
    Solomon, Justin
    Sahbaee, Pooyan
    Saboury, Babak
    Pritchard, William F.
    Jones, Elizabeth C.
    Samei, Ehsan
    ACADEMIC RADIOLOGY, 2021, 28 (12) : 1754 - 1760
  • [26] Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study
    Bornefalk, Hans
    Danielsson, Mats
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07): : 1999 - 2022
  • [27] Feasibility of photon-counting CT for femoroacetabular impingement syndrome evaluation: lower radiation dose and improved diagnostic confidence
    Ferrero, Andrea
    Powell, Garret M.
    Adaaquah, Dennis K.
    Rajendran, Kishore
    Thorne, Jamison E.
    Krych, Aaron J.
    Horst, Kelly K.
    McCollough, Cynthia H.
    Baffour, Francis I.
    SKELETAL RADIOLOGY, 2023, 52 (09) : 1651 - 1659
  • [28] Feasibility of photon-counting CT for femoroacetabular impingement syndrome evaluation: lower radiation dose and improved diagnostic confidence
    Andrea Ferrero
    Garret M. Powell
    Dennis K. Adaaquah
    Kishore Rajendran
    Jamison E. Thorne
    Aaron J. Krych
    Kelly K. Horst
    Cynthia H. McCollough
    Francis I. Baffour
    Skeletal Radiology, 2023, 52 : 1651 - 1659
  • [29] Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT
    Oechsner, Tim
    Soschynski, Martin
    Schlett, Christopher L.
    Krauss, Tobias
    Schupppert, Christopher
    Mueller-Peltzer, Katharina
    Vecsey-Nagy, Milan
    Kravchenko, Dmitrij
    Varga-Szemes, Akos
    Emrich, Tilman
    Scheu, Raphael
    Taron, Jana
    Bamberg, Fabian
    Hagar, Muhammad Taha
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 183
  • [30] Feasibility of photon-counting spectral CT in dental applications—a comparative qualitative analysis
    L. Vanden Broeke
    M. Grillon
    A. W. K. Yeung
    W. Wu
    R. Tanaka
    V. Vardhanabhuti
    BDJ Open, 7