Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans

被引:144
|
作者
Symons, Rolf [1 ]
Pourmorteza, Amir [1 ]
Sandfort, Veit [1 ]
Ahlman, Mark A. [1 ]
Cropper, Tracy [1 ]
Mallek, Marissa [1 ]
Kappler, Steffen [2 ]
Ulzheimer, Stefan [2 ]
Mahesh, Mahadevappa [3 ]
Jones, Elizabeth C. [1 ]
Malayeri, Ashkan A. [1 ]
Folio, Les R. [1 ]
Bluemke, David A. [1 ]
机构
[1] NIH, Dept Radiol & Imaging Sci, Clin Ctr, 10 Ctr Dr, Bethesda, MD 20892 USA
[2] Siemens Healthcare, Forchheim, Germany
[3] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
基金
美国国家卫生研究院;
关键词
LUNG-CANCER; IMAGE NOISE; PERFORMANCE; ARTIFACTS; SOCIETY; QUALITY; IMPACT; MODEL;
D O I
10.1148/radiol.2017162587
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate whether photon-counting detector (PCD) technology can improve dose-reduced chest computed tomography (CT) image quality compared with that attained with conventional energy-integrating detector (EID) technology in vivo. Materials and Methods: This was a HIPAA-compliant institutional review board-approved study, with informed consent from patients. Dose-reduced spiral unenhanced lung EID and PCD CT examinations were performed in 30 asymptomatic volunteers in accordance with manufacturer-recommended guidelines for CT lung cancer screening (120-kVp tube voltage, 20-mAs reference tube current-time product for both detectors). Quantitative analysis of images included measurement of mean attenuation, noise power spectrum (NPS), and lung nodule contrast-to-noise ratio (CNR). Images were qualitatively analyzed by three radiologists blinded to detector type. Reproducibility was assessed with the intraclass correlation coefficient (ICC). McNemar, paired t, and Wilcoxon signed-rank tests were used to compare image quality. Results: Thirty study subjects were evaluated (mean age, 55.0 years +/- 8.7 [ standard deviation]; 14 men). Of these patients, 10 had a normal body mass index (BMI) (BMI range, 18.5-24.9 kg/m(2); group 1), 10 were overweight (BMI range, 25.0-29.9 kg/m(2); group 2), and 10 were obese (BMI. 30.0 kg/m(2), group 3). PCD diagnostic quality was higher than EID diagnostic quality (P = .016, P = .016, and P = .013 for readers 1, 2, and 3, respectively), with significantly better NPS and image quality scores for lung, soft tissue, and bone and with fewer beam-hardening artifacts (P < .001). Image noise was significantly lower for PCD images in all BMI groups (P < .001 for groups 1 and 3, P < .01 for group 2), with higher CNR for lung nodule detection (12.1 +/- 6 1.7 vs 10.0 +/- 6 1.8, P < .001). Inter-and intrareader reproducibility were good (all ICC > 0.800). Conclusion: Initial human experience with dose-reduced PCD chest CT demonstrated lower image noise compared with conventional EID CT, with better diagnostic quality and lung nodule CNR.
引用
收藏
页码:980 / 989
页数:10
相关论文
共 50 条
  • [31] Feasibility of photon-counting spectral CT in dental applications - a comparative qualitative analysis
    Vanden Broeke, L.
    Grillon, M.
    Yeung, A. W. K.
    Wu, W.
    Tanaka, R.
    Vardhanabhuti, V.
    BDJ OPEN, 2021, 7 (01)
  • [32] Photon-counting CT Material Decomposition: Initial Experience in Assessing Adrenal Adenoma
    Lennartz, Simon
    Schoenbeck, Denise
    Kroeger, Jan Robert
    Borggrefe, Jan
    Niehoff, Julius Henning
    RADIOLOGY, 2023, 306 (01) : 202 - 204
  • [33] Material separation in x-ray CT with energy resolved photon-counting detectors
    Wang, Xiaolan
    Meier, Dirk
    Taguchi, Katsuyuki
    Wagenaar, Douglas J.
    Patt, Bradley E.
    Frey, Eric C.
    MEDICAL PHYSICS, 2011, 38 (03) : 1534 - 1546
  • [34] Material Separation in X-ray CT with Energy Resolved Photon-Counting Detectors
    Wang, X.
    Meier, D.
    Taguchi, K.
    Wagenaar, D. J.
    Patt, B. E.
    Frey, E. C.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [35] The Feasibility of the Dual-Dictionary Method for Breast Computed Tomography Based On Photon-Counting Detectors
    Zhao, B.
    Ding, H.
    Lu, Y.
    Wang, G.
    Zhao, J.
    Molloi, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3915 - 3916
  • [36] Low Dose Breast CT with Photon Counting Detectors: A Phantom Study
    Le, H.
    Ducote, J.
    Klopfer, M.
    Molloi, S.
    MEDICAL PHYSICS, 2009, 36 (06) : 2467 - +
  • [37] Quantitative Contrast-Enhanced Spectral Mammography Based On Photon-Counting Detectors: A Feasibility Study
    Ding, H.
    Zhou, B.
    Beidokhti, D.
    Molloi, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3817 - 3818
  • [38] Quantitative contrast-enhanced spectral mammography based on photon-counting detectors: A feasibility study
    Ding, Huanjun
    Molloi, Sabee
    MEDICAL PHYSICS, 2017, 44 (08) : 3939 - 3951
  • [39] CT Angiography of the Aorta Using Photon-counting Detector CT with Reduced Contrast Media Volume
    Higashigaito, Kai
    Mergen, Victor
    Eberhard, Matthias
    Jungblut, Lisa
    Hebeisen, Monika
    Ratzer, Susan
    Zanini, Bettina
    Kobe, Adrian
    Martini, Katharina
    Euler, Andre
    Alkadhi, Hatem
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2023, 5 (01):
  • [40] Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT
    Decker, Josua A.
    Bette, Stefanie
    Lubina, Nora
    Rippel, Katharina
    Braun, Franziska
    Risch, Franka
    Wollny, Claudia
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148