Novel impedimetric aptasensor for label-free detection of Escherichia coil O157:H7

被引:91
|
作者
Brosel-Oliu, Sergi [1 ]
Ferreira, Ruben [1 ]
Uria, Naroa [1 ]
Abramova, Natalia [1 ,2 ]
Gargallo, Raimundo [3 ]
Munoz-Pascual, Francesc-Xavier [1 ]
Bratov, Andrey [1 ]
机构
[1] Esfera UAB CEI, BioMEMS Grp, IMB, CSIC,CNM, Campus UAB, Barcelona 08193, Spain
[2] ITMO Univ, Lab Artificial Sensors Syst, Kronverskiy Pr 49, St Petersburg 197101, Russia
[3] Univ Barcelona, Dept Chem Engn & Analyt Chem, Barcelona, Spain
基金
欧盟第七框架计划;
关键词
Label-free biosensor; Impedimetric transducer; Aptamer; Three-dimensional interdigitated electrode array; E. coli O157:H7; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; COLI O157H7; PATHOGEN DETECTION; BIOSENSORS; BACTERIA; WATER; PERSPECTIVE; APTAMERS; SENSORS;
D O I
10.1016/j.snb.2017.09.121
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microbial safety of drinking water constitutes a major concern in countries at all levels of economic development. Thus, rapid, sensitive and cost effective methods of pathogenic bacteria detection, like common Escherichia coli O157:H7, which can cause important diseases, are highly required. In this work an impedimetric transducer modified with E. coli specific aptamer is studied. To enhance the sensitivity a three-dimensional interdigitated electrode array (3D-IDEA) impedimetric transducer, in which the electrodes are separated by insulating barriers was used. In this sensor chemical reactions at the surface of the barrier provoke electrical charge redistribution which causes changes in the surface conductivity. A DNA aptamer, which recognizes specifically the outer membrane proteins of the E. coli O157:H7, was selected as the biorecognition moiety. Here we report a novel label-free impedimetric aptasensor for detection and quantification of pathogenic E. coli O157:H7 with a low detection limit, good selectivity and short detection time. The developed sensor shows a linear response (R-2 = 0.977), proportional to the logarithm of bacterial concentration present in the sample, with the limit of detection (LOD) of about 10(2) cfu mL(-1). No response of the aptasensor was registered in the presence of other bacterial strains (E. coli k12, Salmonella typhimurium, Staphylococcus aureus), which confirms the selectivity of the suggested detection method. Additionally, the methodology of the aptasensor regeneration was developed, so that the detection may be performed several times with the same sensor. Moreover, suitability of the aptasensor for bacteria detection in real samples was demonstrated with a new approach involving bacteria pre-concentration. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:2988 / 2995
页数:8
相关论文
共 50 条
  • [21] Escherichia coli O157:H7
    Tarr, PI
    Neill, MA
    GASTROENTEROLOGY CLINICS OF NORTH AMERICA, 2001, 30 (03) : 735 - +
  • [22] Escherichia coli O157:H7
    OLoughin, E
    LANCET, 1997, 349 (9064): : 1553 - 1553
  • [23] Chemiluminescent aptasensor capable of rapidly quantifying Escherichia Coli O157:H7
    Khang, Juna
    Kim, Danial
    Chung, Kang Wook
    Lee, Ji Hoon
    TALANTA, 2016, 147 : 177 - 183
  • [24] Label-free capacitive immunosensor based on quartz crystal Au electrode for rapid and sensitive detection of Escherichia coli O157:H7
    Li, Dujuan
    Feng, Yangyang
    Zhou, Ling
    Ye, Zunzhong
    Wang, Jianping
    Ying, Yibin
    Ruan, Chuanmin
    Wang, Ronghui
    Li, Yanbin
    ANALYTICA CHIMICA ACTA, 2011, 687 (01) : 89 - 96
  • [25] A novel smartphone-based colorimetric aptasensor for on-site detection of Escherichia coli O157:H7 in milk
    Yang, Tao
    Wang, Zhenghui
    Song, Yang
    Yang, Xinyan
    Chen, Sihan
    Fu, Shiqian
    Qin, Xue
    Zhang, Wei
    Man, Chaoxin
    Jiang, Yujun
    JOURNAL OF DAIRY SCIENCE, 2021, 104 (08) : 8506 - 8516
  • [26] Direct PCR detection of Escherichia coli O157:H7
    Fode-Vaughan, KA
    Maki, JS
    Benson, JA
    Collins, MLP
    LETTERS IN APPLIED MICROBIOLOGY, 2003, 37 (03) : 239 - 243
  • [27] Rapid detection of Escherichia coli O157:H7 in water
    Bukhari, Zia
    Weihe, Janice R.
    Lechevallier, Mark W.
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2007, 99 (09): : 157 - 167
  • [28] Microsystem for the immunomagnetic detection of Escherichia coli O157:H7
    Mujika, M.
    Arana, S.
    Castano, E.
    Tijero, M.
    Vilares, R.
    Ruano-Lopez, J. M.
    Cruz, A.
    Sainz, L.
    Berganza, J.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2008, 205 (06): : 1478 - 1483
  • [29] Strategies for the detection of Escherichia coli O157:H7 in foods
    Deisingh, A.K. (anildeisingh@aol.com), 1600, Blackwell Publishing Ltd (96):
  • [30] Strategies for the detection of Escherichia coli O157:H7 in foods
    Deisingh, AK
    Thompson, M
    JOURNAL OF APPLIED MICROBIOLOGY, 2004, 96 (03) : 419 - 429