Novel impedimetric aptasensor for label-free detection of Escherichia coil O157:H7

被引:91
|
作者
Brosel-Oliu, Sergi [1 ]
Ferreira, Ruben [1 ]
Uria, Naroa [1 ]
Abramova, Natalia [1 ,2 ]
Gargallo, Raimundo [3 ]
Munoz-Pascual, Francesc-Xavier [1 ]
Bratov, Andrey [1 ]
机构
[1] Esfera UAB CEI, BioMEMS Grp, IMB, CSIC,CNM, Campus UAB, Barcelona 08193, Spain
[2] ITMO Univ, Lab Artificial Sensors Syst, Kronverskiy Pr 49, St Petersburg 197101, Russia
[3] Univ Barcelona, Dept Chem Engn & Analyt Chem, Barcelona, Spain
基金
欧盟第七框架计划;
关键词
Label-free biosensor; Impedimetric transducer; Aptamer; Three-dimensional interdigitated electrode array; E. coli O157:H7; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; COLI O157H7; PATHOGEN DETECTION; BIOSENSORS; BACTERIA; WATER; PERSPECTIVE; APTAMERS; SENSORS;
D O I
10.1016/j.snb.2017.09.121
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microbial safety of drinking water constitutes a major concern in countries at all levels of economic development. Thus, rapid, sensitive and cost effective methods of pathogenic bacteria detection, like common Escherichia coli O157:H7, which can cause important diseases, are highly required. In this work an impedimetric transducer modified with E. coli specific aptamer is studied. To enhance the sensitivity a three-dimensional interdigitated electrode array (3D-IDEA) impedimetric transducer, in which the electrodes are separated by insulating barriers was used. In this sensor chemical reactions at the surface of the barrier provoke electrical charge redistribution which causes changes in the surface conductivity. A DNA aptamer, which recognizes specifically the outer membrane proteins of the E. coli O157:H7, was selected as the biorecognition moiety. Here we report a novel label-free impedimetric aptasensor for detection and quantification of pathogenic E. coli O157:H7 with a low detection limit, good selectivity and short detection time. The developed sensor shows a linear response (R-2 = 0.977), proportional to the logarithm of bacterial concentration present in the sample, with the limit of detection (LOD) of about 10(2) cfu mL(-1). No response of the aptasensor was registered in the presence of other bacterial strains (E. coli k12, Salmonella typhimurium, Staphylococcus aureus), which confirms the selectivity of the suggested detection method. Additionally, the methodology of the aptasensor regeneration was developed, so that the detection may be performed several times with the same sensor. Moreover, suitability of the aptasensor for bacteria detection in real samples was demonstrated with a new approach involving bacteria pre-concentration. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:2988 / 2995
页数:8
相关论文
共 50 条
  • [31] Conductometric immunosensor for specific Escherichia coli O157:H7 detection on chemically funcationalizaed interdigitated aptasensor
    Uda, Muhammad Nur Afnan
    Dafhalla, Alaa Kamal Yousif
    Dhahi, Thikra S.
    Adam, Tijjani
    Gopinath, Subash Chandra Bose
    Ambek, Asral Bahari
    Uda, Muhammad Nur Aiman
    Mohammed, Mohammed
    Parmin, Nor Azizah
    Ibrahim, Nur Hulwani
    Hashim, Uda
    HELIYON, 2024, 10 (05)
  • [32] Functional nanozyme mediated multi-readout and label-free lateral flow immunoassay for rapid detection of Escherichia coli O157:H7
    Wang, Zonghan
    Yao, Xiaolin
    Zhang, Yongzhi
    Wang, Rong
    Ji, Yanwei
    Sun, Jing
    Zhang, Daohong
    Wang, Jianlong
    FOOD CHEMISTRY, 2020, 329
  • [33] Label-Free 3D Ag Nanoflower-Based Electrochemical Immunosensor for the Detection of Escherichia coli O157:H7 Pathogens
    Huang, He
    Liu, Minghuan
    Wang, Xiangsheng
    Zhang, Wenjie
    Yang, Da-Peng
    Cui, Lianhua
    Wang, Xiansong
    NANOSCALE RESEARCH LETTERS, 2016, 11
  • [34] Label-Free 3D Ag Nanoflower-Based Electrochemical Immunosensor for the Detection of Escherichia coli O157:H7 Pathogens
    He Huang
    Minghuan Liu
    Xiangsheng Wang
    Wenjie Zhang
    Da-Peng Yang
    Lianhua Cui
    Xiansong Wang
    Nanoscale Research Letters, 2016, 11
  • [35] Defects in polynucleotide phosphorylase impairs virulence in Escherichia coil O157:H7
    Hu, Jia
    Zhu, Mei-Jun
    FRONTIERS IN MICROBIOLOGY, 2015, 6
  • [36] Polymerase chain reaction assay for detection of Escherichia coli O157: H7 and Escherichia coli O157:H-
    Miyamoto, T
    Ichioka, N
    Sasaki, C
    Kobayashi, H
    Honjoh, K
    Iio, M
    Hatano, S
    JOURNAL OF FOOD PROTECTION, 2002, 65 (01) : 5 - 11
  • [37] Update on Escherichia coli O157:H7
    Lawson J.M.
    Current Gastroenterology Reports, 2004, 6 (4) : 297 - 301
  • [38] Prevalence of Escherichia coli O157:H7
    Dekoninck, A
    Blaton, B
    Lontie, M
    Verhaegen, J
    ACTA CLINICA BELGICA, 1998, 53 (01): : 55 - 56
  • [39] A new label-free impedimetric aptasensor for gluten detection
    Malvano, Francesca
    Albanese, Donatella
    Pilloton, Roberto
    Di Matteo, Marisa
    FOOD CONTROL, 2017, 79 : 200 - 206
  • [40] Escherichia coli O157:H7 in milk
    Kirk, JH
    Price, S
    Wright, JC
    LARGE ANIMAL PRACTICE, 1997, 18 (02): : 16 - +