Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?

被引:10
|
作者
Lee, Seung Hyun [1 ]
Chang, Byung Chul [1 ]
Youn, Young-Nam [1 ]
Joo, Hyun Chel [1 ]
Yoo, Kyung-Jong [1 ]
Lee, Sak [1 ]
机构
[1] Yonsei Univ, Coll Med, Yonsei Cardiovasc Res Inst, Severance Cardiovasc Hosp,Div Thorac & Cardiovasc, 250 Seongsanno, Seoul 03722, South Korea
来源
关键词
Heart valve prosthesis; Hemodynamics; Mitral valve; Mortality; Surgery; Valves; SURVIVAL; REGURGITATION; OUTCOMES;
D O I
10.1186/s13019-017-0653-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Prosthesis-patient mismatch (PPM) is characterised by the effects of inadequate prosthesis size relative to body surface area (BSA). The purpose of this study was to determine the impact of PPM on late clinical outcomes after mitral valve replacement (MVR) in rheumatic population. Methods: From 2000 to 2013, a total of 445 patients (mean age 54.2 +/- 11.7 years) underwent isolated MVR (+/- tricuspid annuloplasty) for rheumatic disease were investigated. Effective orifice area (EOA) was determined by the continuity equation and PPM was defined as indexed EOA (EOA/BSA) <= 1.2 cm(2)/m(2). Clinical and echocardiographic follow-up (mean follow up 8.7 +/- 4.0 years) results were compared. Results: 37% of patients (n = 165) had PPM. There were no significant differences in baseline and operative characteristics between patients with and without PPM except age and IEOA. A significant decrease in mean trans-valvular pressure gradient (MPG) over time following MVR, however the change of MPG showed no differences between groups (No PPM vs. PPM: 8.9 +/- 4.7 mmHg -> 3.6 +/- 1.2 mmHg vs. 8.7 +/- 4.5 mmHg. 3.8 +/- 1.4 mmHg, p-value = 0.28). In all patients, there was a reduction of left atrium dimension (58.6 +/- 12.0 mm. 53.2 +/- 12.0 mm vs. 57.9 +/- 8.9 mm -> 52.2 +/- 8.9 mm, p-value = 0.68) and left ventricular end diastolic diameter (49.9 +/- 5.7 mm -> 48.9 +/- 5.7 mm vs. 49.7 +/- 6.0 mm -> 48.3 +/- 5.0 mm, p = 0.24) without statistical significance. Freedom from TR progression rates at 3 and 5 years (99% vs. 98%, 99% vs. 98%, p-value = 0.1), and overall survival rates at 3 and 5 years (97% vs. 96%, 94% vs. 94%, p-value = 0.7) were similar. Conclusion: This study shows that mitral PPM is not associated with atrial/ventricular remodeling and might not influence late clinical outcome including late TR progression, survival in rheumatic population.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Sa, Michel Pompeu
    Jacquemyn, Xander
    Van den Eynde, Jef
    Tasoudis, Panagiotis
    Dokollari, Aleksander
    Torregrossa, Gianluca
    Sicouri, Serge
    Clavel, Marie-Annick
    Pibarot, Philippe
    Ramlawi, Basel
    JACC-CARDIOVASCULAR IMAGING, 2022, 16 (03) : 298 - 310
  • [22] Late results after mitral valve replacement with bileaflet mechanical prosthesis in children: Evaluation of prosthesis-patient mismatch
    Masuda, M
    Kado, H
    Tatewaki, H
    Shiokawa, Y
    Yasui, H
    ANNALS OF THORACIC SURGERY, 2004, 77 (03): : 913 - 917
  • [23] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Levesque, Thomas
    Eltchaninoff, Helene
    Chabannes, Romain
    Barbe, Thomas
    Dosseh, Olivier
    Tron, Christophe
    Bettinger, Nicolas
    Bouhzam, Najime
    Hemery, Thibaut
    le Pessec, Guillaume
    Fauvel, Charles
    Cribier, Alain
    Pibarot, Philippe
    Durand, Eric
    CANADIAN JOURNAL OF CARDIOLOGY, 2024, 40 (01) : 113 - 122
  • [24] Impact of prosthesis-patient mismatch on tricuspid valve regurgitation and pulmonary hypertension following mitral valve replacement
    Angeloni, Emiliano
    Melina, Giovanni
    Benedetto, Umberto
    Roscitano, Antonino
    Refice, Simone
    Quarto, Cesare
    Comito, Cosimo
    Pibarot, Philippe
    Sinatra, Riccardo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) : 4150 - 4154
  • [25] Factors Affecting Survival After Mitral Valve Replacement in Patients With Prosthesis-Patient Mismatch DISCUSSION
    Kon, Neal D.
    Aziz
    Moon, Marc R.
    Thourani, Vinod H.
    Heck, Herman A.
    Accola, Kevin D.
    ANNALS OF THORACIC SURGERY, 2010, 90 (04): : 1210 - 1211
  • [26] Prosthesis-Patient Mismatch and Mitral Regurgitation After Aortic Valve Replacement: A Prospective Quantitative Study
    Unger, Philippe
    Vanden Eynden, Frederic
    Plein, Daniele
    Van Camp, Guy
    Pasquet, Agnes
    Cosyns, Bernard
    Dedobbeleer, Chantal
    Lancellottti, Patrizio
    CIRCULATION, 2009, 120 (18) : S768 - S768
  • [27] Aortic Valve Prosthesis-Patient Mismatch in a Patient Undergoing Redo Mitral Valve Replacement for Infective Endocarditis
    Lahori, Anna
    Frogel, Jonathan
    Augoustides, John G.
    Patel, Prakash A.
    Vernick, William J.
    Gutsche, Jacob T.
    Feinman, Jared W.
    Patel, Saumil
    Munroe, Ray
    MacKay, Emily J.
    Weiss, Stuart J.
    Dwarakanath, Sanjay
    Sheu, Richard D.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (06) : 2802 - 2809
  • [28] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [29] Prosthesis-patient Mismatch after Mitral Valve Replacement Stratified by Referred and Measured Effective Valve Area
    Matsuura, Kaoru
    Mogi, Kenji
    Aoki, Chikashi
    Takahara, Yoshiharu
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 17 (02) : 153 - 159
  • [30] Prosthesis-patient mismatch in the mitral position: Old concept, new evidences
    Pibarot, Philippe
    Dumesnil, Jean G.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (06): : 1405 - 1408