Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?

被引:10
|
作者
Lee, Seung Hyun [1 ]
Chang, Byung Chul [1 ]
Youn, Young-Nam [1 ]
Joo, Hyun Chel [1 ]
Yoo, Kyung-Jong [1 ]
Lee, Sak [1 ]
机构
[1] Yonsei Univ, Coll Med, Yonsei Cardiovasc Res Inst, Severance Cardiovasc Hosp,Div Thorac & Cardiovasc, 250 Seongsanno, Seoul 03722, South Korea
来源
关键词
Heart valve prosthesis; Hemodynamics; Mitral valve; Mortality; Surgery; Valves; SURVIVAL; REGURGITATION; OUTCOMES;
D O I
10.1186/s13019-017-0653-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Prosthesis-patient mismatch (PPM) is characterised by the effects of inadequate prosthesis size relative to body surface area (BSA). The purpose of this study was to determine the impact of PPM on late clinical outcomes after mitral valve replacement (MVR) in rheumatic population. Methods: From 2000 to 2013, a total of 445 patients (mean age 54.2 +/- 11.7 years) underwent isolated MVR (+/- tricuspid annuloplasty) for rheumatic disease were investigated. Effective orifice area (EOA) was determined by the continuity equation and PPM was defined as indexed EOA (EOA/BSA) <= 1.2 cm(2)/m(2). Clinical and echocardiographic follow-up (mean follow up 8.7 +/- 4.0 years) results were compared. Results: 37% of patients (n = 165) had PPM. There were no significant differences in baseline and operative characteristics between patients with and without PPM except age and IEOA. A significant decrease in mean trans-valvular pressure gradient (MPG) over time following MVR, however the change of MPG showed no differences between groups (No PPM vs. PPM: 8.9 +/- 4.7 mmHg -> 3.6 +/- 1.2 mmHg vs. 8.7 +/- 4.5 mmHg. 3.8 +/- 1.4 mmHg, p-value = 0.28). In all patients, there was a reduction of left atrium dimension (58.6 +/- 12.0 mm. 53.2 +/- 12.0 mm vs. 57.9 +/- 8.9 mm -> 52.2 +/- 8.9 mm, p-value = 0.68) and left ventricular end diastolic diameter (49.9 +/- 5.7 mm -> 48.9 +/- 5.7 mm vs. 49.7 +/- 6.0 mm -> 48.3 +/- 5.0 mm, p = 0.24) without statistical significance. Freedom from TR progression rates at 3 and 5 years (99% vs. 98%, 99% vs. 98%, p-value = 0.1), and overall survival rates at 3 and 5 years (97% vs. 96%, 94% vs. 94%, p-value = 0.7) were similar. Conclusion: This study shows that mitral PPM is not associated with atrial/ventricular remodeling and might not influence late clinical outcome including late TR progression, survival in rheumatic population.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] The relevance of prosthesis-patient mismatch after aortic valve replacement
    Pibarot, Philippe
    Dumesnil, Jean G.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (12): : 764 - 765
  • [32] Impact of prosthesis-patient mismatch on early and late outcomes after mitral valve replacement: a meta-analysis
    Meng-Wei TAN
    Yi-Fan BAI
    Xiao-Hong LIU
    Zhi-Yun XU
    Zhao AN
    Ye MA
    Li-Bo ZHAO
    Bai-Ling LI
    Journal of Geriatric Cardiology, 2020, 17 (08) : 455 - 475
  • [33] Impact of prosthesis-patient mismatch on early and late outcomes after mitral valve replacement: a meta-analysis
    Meng-Wei TAN
    Yi-Fan BAI
    Xiao-Hong LIU
    Zhi-Yun XU
    Zhao AN
    Ye MA
    Li-Bo ZHAO
    Bai-Ling LI
    Journal of Geriatric Cardiology, 2020, 17 (08) : 455 - 475
  • [34] VALVE PROSTHESIS-PATIENT MISMATCH - REPLY
    RAHIMTOOLA, SS
    CIRCULATION, 1979, 59 (02) : 418 - 419
  • [35] Impact of Prosthesis-Patient Mismatch on Late Recurrence of Atrial Fibrillation After Cryomaze Procedure With Mitral Valve Replacement
    Sato, Shunsuke
    Fujita, Tomoyuki
    Shimahara, Yusuke
    Hata, Hiroki
    Kobayashi, Junjiro
    CIRCULATION JOURNAL, 2014, 78 (08) : 1908 - 1914
  • [36] Impact of prosthesis-patient mismatch on early and late outcomes after mitral valve replacement: a meta-analysis
    Tan, Meng-Wei
    Bai, Yi-Fan
    Liu, Xiao-Hong
    Xu, Zhi-Yun
    An, Zhao
    Ma, Ye
    Zhao, Li-Bo
    Li, Bai-Ling
    JOURNAL OF GERIATRIC CARDIOLOGY, 2020, 17 (08) : 455 - 475
  • [37] Valve prosthesis-patient mismatch: An update
    Rahimtoola, SH
    JOURNAL OF HEART VALVE DISEASE, 1998, 7 (02): : 207 - 210
  • [38] Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch
    Kim, Hyo-Hyun
    Lee, Sak
    Joo, Hyun-Chel
    Kim, Jung-Hwan
    Youn, Young-Nam
    Yoo, Kyung-Jong
    Lee, Seung-Hyun
    ANNALS OF THORACIC SURGERY, 2020, 109 (03): : 661 - 667
  • [39] Prosthesis-patient mismatch following aortic and mitral valves replacement - A comprehensive review
    Joury, Abdulaziz
    Duran, Antonio
    Stewart, Merrill
    Gilliland, Yvonne E.
    Spindel, Stephen M.
    Qamruddin, Salima
    PROGRESS IN CARDIOVASCULAR DISEASES, 2022, 72 : 84 - 92
  • [40] Enlargement of Mitral Valve Ring in a Young Woman with Severe Prosthesis-Patient Mismatch
    Attisani, Matteo
    Pellegrini, Augusto
    Sorrentino, Paolo
    Rinaldi, Mauro
    HEART SURGERY FORUM, 2014, 17 (02): : E61 - E63