Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement

被引:11
|
作者
Levesque, Thomas [1 ]
Eltchaninoff, Helene [1 ]
Chabannes, Romain [1 ]
Barbe, Thomas [1 ]
Dosseh, Olivier [1 ]
Tron, Christophe [1 ]
Bettinger, Nicolas [1 ]
Bouhzam, Najime [1 ]
Hemery, Thibaut [1 ]
le Pessec, Guillaume [1 ]
Fauvel, Charles [1 ]
Cribier, Alain [1 ]
Pibarot, Philippe [2 ]
Durand, Eric [1 ,3 ]
机构
[1] Normandie Univ, Dept Cardiol, UNIROUEN, U1096,CHU Rouen, Rouen, France
[2] Univ Laval, Inst Univ Cardiol & Pneumol Quebec, Dept Cardiol, Quebec City, PQ, Canada
[3] Charles Nicolle Hosp, Dept Cardiol, 1 rue Germont, Rouen, France
关键词
HIGH-RISK PATIENTS; CLINICAL IMPACT; TRIAL; CALCIFICATION; PREDICTORS; OUTCOMES; STENOSIS;
D O I
10.1016/j.cjca.2023.09.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Data on the long-term impact of prosthesis-patient mismatch (PPM) on outcomes after transcatheter aortic valve replacement (TAVR) remain sparse. We therefore aimed to investigate the incidence, predictive factors, and long-term prognostic impact of PPM on bioprosthesis durability and mortality. Methods: This was a single-centre retrospective study including 2117 patients who underwent TAVR for aortic stenosis from 2002 to 2022. Moderate PPM was defined by indexed effective orifice area (iEOA) > 0.65 and <= 0.85 cm(2)/m(2) (> 0.55 and <= 0.70 cm(2)/m(2) if BMI >= 30 kg/m(2)) and severe PPM by an iEOA <= 0.65 cm(2)/m(2) (<= 0.55 cm(2)/m(2) If BMI >= 30 kg/m(2)). Results: There were 351 patients (16.6%) with PPM, including 39 patients (1.8%) with severe PPM and 312 patients (14.7%) with moderate PPM. The mean follow-up duration was 31.2 +/- 26.5 months. Factors independently associated with the occurrence of PPM were body surface area (odds ratio [OR] 3.32, 95% confidence interval [CI] 1.32-8.35; P = 0.01), valve-in-valve TAVR (OR 6.12, 95% CI 2.29-16.08; P < 0.001), small annulus (OR 2.42, 95% CI 1.41-4.07; P = 0.001), and the use of a balloon-expandable valve (OR 4.17, 95% CI 2.17-8.33; P < 0.001). PPM was associated with increased risk of mortality (hazard ratio [HR] 1.3, 95% CI 1.1-1.5, P = 0.004) and valve thrombosis (HR 4.2, 95% CI 1.4-12.6, P = 0.01), and a trend towards increased risk of structural valve deterioration (HR 1.7, 95% CI 0.9-2.9; P = 0.08). Conclusions: The results of this study suggest that PPM has a negative long-term impact on outcomes after TAVR. These findings emphasise the importance of preventing PPM.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 50 条
  • [1] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Sa, Michel Pompeu
    Jacquemyn, Xander
    Van den Eynde, Jef
    Tasoudis, Panagiotis
    Dokollari, Aleksander
    Torregrossa, Gianluca
    Sicouri, Serge
    Clavel, Marie-Annick
    Pibarot, Philippe
    Ramlawi, Basel
    JACC-CARDIOVASCULAR IMAGING, 2022, 16 (03) : 298 - 310
  • [2] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [3] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement in Asian Patients
    Chen, Ying-Hwa
    Chang, Hsiao-Huang
    Kuo, Chia-Cheng
    Leu, Hsin-Bang
    Lin, Su-Man
    ANNALS OF THORACIC SURGERY, 2022, 114 (05): : 1612 - 1619
  • [4] Impact of Measured and Predicted Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Guthoff, Henning
    Abdel-Wahab, Mohamed
    Kim, Won-Keun
    Witberg, Guy
    Wienemann, Hendrik
    Thurow, Maria
    Shamekhi, Jasmin
    Eckel, Clemens
    von der Heide, Ina
    Veulemans, Verena
    Landt, Martin
    Barbanti, Marco
    Finkelstein, Ariel
    Schewel, Jury
    Van Mieghem, Nicolas
    Adrichem, Rik
    Toggweiler, Stefan
    Rheude, Tobias
    Nombela-Franco, Luis
    Amat-Santos, Ignacio J.
    Ruile, Philipp
    Estevez-Loureiro, Rodrigo
    Bunc, Matjaz
    Branca, Luca
    De Backer, Ole
    Tarantini, Giuseppe
    Mylotte, Darren
    Arzamendi, Dabit
    Pauly, Markus
    Bleiziffer, Sabine
    Renker, Matthias
    Al-Kassou, Baravan
    Mollmann, Helge
    Ludwig, Sebastian
    Zeus, Tobias
    Tamburino, Corrado
    Schmidt, Tobias
    Rueck, Andreas
    von Stein, Philipp
    Thiele, Holger
    Abdelhafez, Ahmed
    Adam, Matti
    Baldus, Stephan
    Rudolph, Tanja
    Mauri, Victor
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (22) : 2626 - 2635
  • [5] Overcoming prosthesis-patient mismatch with transcatheter aortic valve replacement
    Grubb, Kendra J.
    Tom, Stephanie K.
    Sultan, Ibrahim
    Sa, Michel Pompeu
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 236 - 243
  • [6] Prosthesis-Patient Mismatch in the Transcatheter Aortic Valve Replacement Era
    Tuzcu, E. Murat
    Oezkan, Alper
    Kapadia, Samir R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1919 - 1922
  • [7] Prosthesis-patient mismatch in transcatheter and surgical aortic valve replacement
    Hahn, Rebecca T.
    Pibarot, Philippe
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 211 - 223
  • [8] Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement
    Abbas, Amr E.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (01) : 138 - 138
  • [9] Relative prosthesis-patient mismatch after transcatheter aortic valve replacement: The impact of morbid obesity
    Airhart, Sophia
    Medvedev, Ivan
    Dean, Larry S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (02) : 341 - 345
  • [10] Racial Differences in the Incidence and Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Park, Hanbit
    Ahn, Jung-Min
    Kang, Do-Yoon
    Kim, Juyong Brian
    Yeung, Alan C.
    Nishi, Takeshi
    Fearon, William F.
    Cantey, Eric Page
    Flaherty, James D.
    Davidson, Charles J.
    Malaisrie, S. Christopher
    Kim, Sehee
    Yun, Sung-Cheol
    Ko, Euihong
    Lee, Seung-Ah
    Kim, Dae-Hee
    Kim, Ho Jin
    Kim, Joon Bum
    Choo, Suk Jung
    Park, Duk-Woo
    Park, Seung-Jung
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (24) : 2670 - 2681