Aortic Valve Prosthesis-Patient Mismatch in a Patient Undergoing Redo Mitral Valve Replacement for Infective Endocarditis

被引:1
|
作者
Lahori, Anna [1 ]
Frogel, Jonathan [1 ]
Augoustides, John G. [2 ]
Patel, Prakash A. [2 ]
Vernick, William J. [2 ]
Gutsche, Jacob T. [2 ]
Feinman, Jared W. [2 ]
Patel, Saumil [2 ]
Munroe, Ray [2 ]
MacKay, Emily J. [2 ]
Weiss, Stuart J. [2 ]
Dwarakanath, Sanjay [3 ]
Sheu, Richard D. [4 ]
机构
[1] Sheba Med Ctr, Dept Anesthesiol, Cardiovasc & Thorac Sect, Tel Hashomer, Israel
[2] Univ Penn, Cardiovasc & Thorac Sect, Dept Anesthesiol & Crit Care, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Univ Kentucky, Sch Med, Dept Anesthesiol, Lexington, KY 40536 USA
[4] Univ Washington, Med Ctr, Dept Anesthesiol & Pain Med, Seattle, WA 98195 USA
关键词
endocarditis; transesophageal echocardiography; transthoracic echocardiography; cardiopulmonary bypass; prosthesis-patient mismatch; effective orifice area; geometric orifice area; anatomic orifice area; body surface area; dimensionless index; acceleration time; left ventricular outflow tract; three-dimensional echocardiography; transcatheter aortic valve replacement; valve-in-valve intervention; VENTRICULAR OUTFLOW TRACT; EFFECTIVE ORIFICE AREA; LONG-TERM SURVIVAL; HIGH-RISK PATIENTS; ECHOCARDIOGRAPHIC-ASSESSMENT; CLINICAL UPDATE; CARDIAC EVENTS; IMPACT; TRANSCATHETER; STENOSIS;
D O I
10.1053/j.jvca.2018.02.016
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
[No abstract available]
引用
收藏
页码:2802 / 2809
页数:8
相关论文
共 50 条
  • [1] Prosthesis-patient mismatch after aortic valve replacement
    Dahou A.
    Mahjoub H.
    Pibarot P.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (11)
  • [2] Impact of prosthesis-patient mismatch on mitral regurgitation after aortic valve replacement
    Unger, P.
    Magne, J.
    Eynden, F. Vanden
    Plein, D.
    Van Camp, G.
    Pasquet, A.
    Cosyns, B.
    Dedobbeleer, C.
    Lancellotti, P.
    HEART, 2010, 96 (20) : 1627 - 1632
  • [3] Overcoming prosthesis-patient mismatch with transcatheter aortic valve replacement
    Grubb, Kendra J.
    Tom, Stephanie K.
    Sultan, Ibrahim
    Sa, Michel Pompeu
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 236 - 243
  • [4] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [5] Prosthesis-Patient Mismatch in the Transcatheter Aortic Valve Replacement Era
    Tuzcu, E. Murat
    Oezkan, Alper
    Kapadia, Samir R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1919 - 1922
  • [6] Prosthesis-patient mismatch in transcatheter and surgical aortic valve replacement
    Hahn, Rebecca T.
    Pibarot, Philippe
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 211 - 223
  • [7] The relevance of prosthesis-patient mismatch after aortic valve replacement
    Pibarot, Philippe
    Dumesnil, Jean G.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (12): : 764 - 765
  • [8] Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement
    Abbas, Amr E.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (01) : 138 - 138
  • [9] Prosthesis-Patient Mismatch and Mitral Regurgitation Persistence Late after Aortic Valve Replacement
    Angeloni, Emiliano
    Benedetto, Umberto
    Refice, Simone
    Santini, Daria
    Ciavarella, Giuseppino M.
    Roscitano, Antonino
    Melina, Giovanni
    Sinatra, Riccardo
    CIRCULATION, 2010, 122 (21)
  • [10] Prosthesis-patient mismatch after mitral valve replacement: Back to reality
    Pibarot, Philippe
    Magne, Julien
    Dumesnil, Jean G.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (02): : 464 - 465