Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy

被引:123
|
作者
Xie, Yunhe [1 ]
Bentefour, El Hassane [2 ]
Janssens, Guillaume [2 ]
Smeets, Julien [2 ]
Vander Stappen, Francois [2 ]
Hotoiu, Lucian [2 ]
Yin, Lingshu [1 ]
Dolney, Derek [1 ]
Avery, Stephen [1 ]
O'Grady, Fionnbarr [1 ]
Prieels, Damien [2 ]
McDonough, James [1 ]
Solberg, Timothy D. [3 ]
Lustig, Robert A. [1 ]
Lin, Alexander [1 ]
Teo, Boon-Keng K. [1 ]
机构
[1] Univ Penn, Dept Radiat Oncol, 3400 Civ Ctr Blvd,TRC 2 W, Philadelphia, PA 19104 USA
[2] Ion Beam Applicat SA, Adv Technol Grp, Louvain La Neuve, Belgium
[3] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
关键词
CLINICAL-APPLICATION; SLIT CAMERA; EMISSION; SYSTEM; TOMOGRAPHY; DELIVERY; EDGE;
D O I
10.1016/j.ijrobp.2017.04.027
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode. Methods and Materials: A stand-alone,trolley-mounted, prototype prompt gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan. Results: In 6 treatment fractions recorded over 3 weeks, the mean ( +/- standard deviation) range shifts aggregated over all spots in 9 energy layers were -0.8 +/- 1.3 mm for the lateral field, 1.7 +/- 0.7 mm for the right-superior-oblique field, and -0.4 +/- 0.9 mm for the vertex field. Conclusions: This study demonstrates the feasibility and illustrates the distinctive benefits of promptgamma imaging in pencil beam scanning treatmentmode. Accuracy in range verification was found in this first clinical case to be better than the range uncertainty margin applied in the treatment plan. These first results lay the foundation for additional work toward tighter integration of the system for in vivo proton range verification and quantification of range uncertainties. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:210 / 218
页数:9
相关论文
共 50 条
  • [21] A feasibility study of enhanced prompt gamma imaging for range verification in proton therapy using deep learning
    Jiang, Zhuoran
    Polf, Jerimy C.
    Barajas, Carlos A.
    Gobbert, Matthias K.
    Ren, Lei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (07):
  • [22] Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy
    Moteabbed, M.
    Espana, S.
    Paganetti, H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04): : 1063 - 1082
  • [23] A 3 Dimensional Prompt Gamma Imaging System for Range Verification in Proton Radiotherapy
    Draeger, E.
    Chen, H.
    Mackin, D.
    Peterson, S.
    Avery, S.
    Beddar, S.
    Polf, J.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3757 - 3757
  • [24] Spectroscopic study of prompt-gamma emission for range verification in proton therapy
    Kelleter, Laurent
    Wronska, Aleksandra
    Besuglow, Judith
    Konefal, Adam
    Laihem, Karim
    Leidner, Johannes
    Magiera, Andrzej
    Parodi, Katia
    Rusiecka, Katarzyna
    Stahl, Achim
    Tessonnier, Thomas
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 7 - 17
  • [25] Range verification of proton radiotherapy with prompt gamma rays
    Lau, Andy
    Chen, Yong
    Ahmad, Salahuddin
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (04) : 507 - 514
  • [26] Range shift verification in spot scanning proton therapy using gamma electron vertex imaging
    Kim, Sung Hun
    Jeong, Jong Hwi
    Ku, Youngmo
    Lee, Se Byeong
    Shin, Dongho
    Lim, Young Kyung
    Kim, Haksoo
    Kim, Chan Hyeong
    [J]. MEDICAL PHYSICS, 2024, 51 (03) : 1985 - 1996
  • [27] Introduction to Pencil Beam Scanning Proton Therapy
    Zhu, M.
    Mossahebi, S.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E275 - E276
  • [28] Experimental Study of Discrete Prompt Gamma Lines for In-Vivo Proton Range Verification
    Verburg, J.
    Riley, K.
    Seco, J.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [29] First clinical application of a prompt gamma based in vivo proton range verification system
    Richter, Christian
    Pausch, Guntram
    Barczyk, Steffen
    Priegnitz, Marlen
    Keitz, Isabell
    Thiele, Julia
    Smeets, Julien
    Stappen, Francois Vander
    Bombelli, Luca
    Fiorini, Carlo
    Hotoiu, Lucian
    Perali, Irene
    Prieels, Damien
    Enghardt, Wolfgang
    Baumann, Michael
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 (02) : 232 - 237
  • [30] Clinical Translation of Prompt Gamma-Ray Spectroscopy for In Vivo Proton Range Verification
    Verburg, J.
    Ruggieri, T.
    Botas, P.
    Cascio, E.
    Hueso-Gonzalez, F.
    Rabe, M.
    BortfeId, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)