Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy

被引:123
|
作者
Xie, Yunhe [1 ]
Bentefour, El Hassane [2 ]
Janssens, Guillaume [2 ]
Smeets, Julien [2 ]
Vander Stappen, Francois [2 ]
Hotoiu, Lucian [2 ]
Yin, Lingshu [1 ]
Dolney, Derek [1 ]
Avery, Stephen [1 ]
O'Grady, Fionnbarr [1 ]
Prieels, Damien [2 ]
McDonough, James [1 ]
Solberg, Timothy D. [3 ]
Lustig, Robert A. [1 ]
Lin, Alexander [1 ]
Teo, Boon-Keng K. [1 ]
机构
[1] Univ Penn, Dept Radiat Oncol, 3400 Civ Ctr Blvd,TRC 2 W, Philadelphia, PA 19104 USA
[2] Ion Beam Applicat SA, Adv Technol Grp, Louvain La Neuve, Belgium
[3] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
关键词
CLINICAL-APPLICATION; SLIT CAMERA; EMISSION; SYSTEM; TOMOGRAPHY; DELIVERY; EDGE;
D O I
10.1016/j.ijrobp.2017.04.027
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode. Methods and Materials: A stand-alone,trolley-mounted, prototype prompt gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan. Results: In 6 treatment fractions recorded over 3 weeks, the mean ( +/- standard deviation) range shifts aggregated over all spots in 9 energy layers were -0.8 +/- 1.3 mm for the lateral field, 1.7 +/- 0.7 mm for the right-superior-oblique field, and -0.4 +/- 0.9 mm for the vertex field. Conclusions: This study demonstrates the feasibility and illustrates the distinctive benefits of promptgamma imaging in pencil beam scanning treatmentmode. Accuracy in range verification was found in this first clinical case to be better than the range uncertainty margin applied in the treatment plan. These first results lay the foundation for additional work toward tighter integration of the system for in vivo proton range verification and quantification of range uncertainties. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:210 / 218
页数:9
相关论文
共 50 条
  • [31] Limitations of, and alternatives to, patient specific verification measurements for pencil beam scanning proton therapy
    Matter, Michael
    Nenoff, Lena
    Meier, Gabriel
    Weber, Damien Charles
    Lomax, Tony
    Albertini, Francesca
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (06) : 601 - 601
  • [32] A comparison of two prompt gamma imaging techniques with collimator-based cameras for range verification in proton therapy
    Lin, Hsin-Hon
    Chang, Hao-Ting
    Chao, Tsi-Chian
    Chuang, Keh-Shih
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 137 : 144 - 150
  • [33] Verification for Prompt Gamma Ray Imaging During Proton Boron Fusion Therapy
    Shin, H.
    Yoon, D.
    Jung, J.
    Kim, M.
    Jang, H.
    Suh, T.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3583 - 3583
  • [34] Prompt Gamma Imaging with a Multi-Knife-Edge Slit Collimator: Evaluation for Use in Proton Beam Range Verification
    Ready, J.
    Negut, V.
    Mihailescu, L.
    Vetter, K.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3717 - 3717
  • [35] Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning
    Tian, Liheng
    Huang, Ze
    Janssens, Guillaume
    Landry, Guillaume
    Dedes, George
    Kamp, Florian
    Belka, Claus
    Pinto, Marco
    Parodi, Katia
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):
  • [36] Can Prompt Gamma Emission During Proton Therapy Provide in Situ Range Verification?
    Styczynski, J.
    Riley, K.
    Binns, P.
    Bortfeld, T.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2425 - +
  • [37] Optimisation of a Prompt-Gamma Slit Imaging System for Particle Beam Range Verification
    Vella, A.
    Van den Heuvel, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S122 - S122
  • [38] Proton Range Shift Verification by Using Gamma Electron Vertex Imaging (GEVI) System in Spot Scanning Proton Therapy
    Kim, S.
    Ku, Y.
    Jung, J.
    Kim, C.
    Jeong, J.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E167 - E167
  • [39] Prompt Gamma Timing Range Verification for Scattered Proton Beams
    Kormoll, T.
    Duplicy, A.
    Fiedler, F.
    Golnik, C.
    Gonzalez, F. Hueso
    Petzoldt, J.
    Swanson, R.
    Thiele, J.
    Weinberger, D.
    Werner, T.
    Enghardt, W.
    Pausch, G.
    [J]. 2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,
  • [40] A Prompt Gamma-Ray Spectroscopy System for Clinical Studies of in Vivo Proton Range Verification
    Verburg, J.
    Bortfeld, T.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3757 - 3757