Range shift verification in spot scanning proton therapy using gamma electron vertex imaging

被引:0
|
作者
Kim, Sung Hun [1 ]
Jeong, Jong Hwi [1 ]
Ku, Youngmo [2 ]
Lee, Se Byeong [1 ]
Shin, Dongho [1 ]
Lim, Young Kyung [1 ]
Kim, Haksoo [1 ]
Kim, Chan Hyeong [2 ,3 ]
机构
[1] Ctr Proton Therapy, Natl Canc Ctr, Goyang Si, Gyeonggi Do, South Korea
[2] Hanyang Univ, Dept Nucl Engn, Seoul, South Korea
[3] Hanyang Univ, Dept Nucl Engn, 222 Wansimni Ro, Seoul 04763, South Korea
关键词
beam range verification; prompt gamma imaging; proton therapy; MEASUREMENT SYSTEM; POSITRON-EMISSION; SLIT-CAMERA; BEAM; PATIENT;
D O I
10.1002/mp.16739
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundIn proton therapy, a highly steep distal dose penumbra can be utilized for dose conformity, given the Bragg peak characteristic of protons. However, the location of the Bragg peak in patients (i.e., the beam range) is very sensitive to range uncertainty. Even a small shift of beam range can produce a significant variation of delivered dose to tumor and normal tissues, thus degrading treatment quality and threatening patient safety. This range uncertainty issue, therefore, is one of the important aspects to be managed in proton therapy.PurposeFor better management of range uncertainty, range verification has been widely studied, and prompt gamma imaging (PGI) is considered one of the promising methods in that effort. In this context, a PGI system named the gamma electron vertex imaging (GEVI) system was developed and recently upgraded for application to pencil-beam scanning (PBS) proton therapy. Here, we report the first experimental results using the therapeutic spot scanning proton beams.MethodsA homogeneous slab phantom and an anthropomorphic phantom were employed. Spherical and cubic planning target volumes (PTVs) were defined. Various range shift scenarios were introduced. Prompt gamma (PG) measurement was synchronized with beam irradiation. The measured PG distributions were aggregated to improve the PG statistics. The range shift was estimated based on the relative change of the centroid in the measured PG distribution. The estimated range shifts were analyzed by range shift mapping, confidence interval (CI) estimation, and statistical hypothesis testing.ResultsThe range shift mapping results showed an obvious measured range shift tendency following the true shift values. However, some fluctuations were found for spots that had still-low PG statistics after spot aggregation. The 99% CI distributions showed clearly distributed range shift measurement data. The overall accuracy and precision for all investigated scenarios were 0.36 and 0.20 mm, respectively. The results of one-sample t-tests confirmed that every shift scenario could be observed up to 1 mm of shift. The ANOVA results proved that the measured range shift data could be discriminated from one another, except for 16 (of 138) comparison cases having 1-2 mm shift differences.ConclusionsThis study demonstrated the feasibility of the GEVI system for measurement of range shift in spot scanning proton therapy. Our experimental results showed that the proton beam can be measured up to 1 mm of range shift with high accuracy and precision. We believe that the GEVI system is one of the most promising PGI systems for in vivo range verification. Further research for application to more various cases and patient treatments is planned.
引用
收藏
页码:1985 / 1996
页数:12
相关论文
共 50 条
  • [1] Proton Range Shift Verification by Using Gamma Electron Vertex Imaging (GEVI) System in Spot Scanning Proton Therapy
    Kim, S.
    Ku, Y.
    Jung, J.
    Kim, C.
    Jeong, J.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E167 - E167
  • [2] Performance prediction of gamma electron vertex imaging (GEVI) system for interfractional range shift detection in spot scanning proton therapy
    Kim, Sung Hun
    Jeong, Jong Hwi
    Ku, Youngmo
    Jung, Jaerin
    Kim, Chan Hyeong
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (06) : 2213 - 2220
  • [3] Gamma electron vertex imaging and application to beam range verification in proton therapy
    Kim, Chan Hyeong
    Park, Jin Hyung
    Seo, Hee
    Lee, Han Rim
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 1001 - 1005
  • [4] Upgrade of gamma electron vertex imaging system for high-performance range verification in pencil beam scanning proton therapy
    Kim, Sung Hun
    Jeong, Jong Hwi
    Ku, Youngmo
    Jung, Jaerin
    Cho, Sungkoo
    Jo, Kwanghyun
    Kim, Chan Hyeong
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (03) : 1016 - 1023
  • [5] Gamma electron vertex imaging and application to beam range verification in proton therapy (vol 39, pg 1001, 2012)
    Kim, Chan Hyeong
    Park, Jin Hyung
    Seo, Hee
    Lee, Han Rim
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6523 - 6524
  • [6] Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy
    Xie, Yunhe
    Bentefour, El Hassane
    Janssens, Guillaume
    Smeets, Julien
    Vander Stappen, Francois
    Hotoiu, Lucian
    Yin, Lingshu
    Dolney, Derek
    Avery, Stephen
    O'Grady, Fionnbarr
    Prieels, Damien
    McDonough, James
    Solberg, Timothy D.
    Lustig, Robert A.
    Lin, Alexander
    Teo, Boon-Keng K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (01): : 210 - 218
  • [7] Comparison of Prompt Gamma and PET Imaging for Range Verification in Proton Therapy
    Moteabbed, M.
    Espana, S.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Gamma electron vertex imaging for in-vivo beam-range measurement in proton therapy: Experimental results
    Kim, Chan Hyeong
    Lee, Han Rim
    Kim, Sung Hun
    Park, Jong Hoon
    Cho, Sungkoo
    Jung, Won Gyun
    [J]. APPLIED PHYSICS LETTERS, 2018, 113 (11)
  • [9] Prototype system for proton beam range measurement based on gamma electron vertex imaging
    Lee, Han Rim
    Kim, Sung Hun
    Park, Jong Hoon
    Jung, Won Gyun
    Lim, Hansang
    Kim, Chan Hyeong
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 857 : 82 - 97
  • [10] Automatic Dose Verification for Spot Scanning Proton Therapy Using Recorded Spot Positions and MUs
    Li, H.
    Li, Y.
    Lii, M.
    Liu, W.
    Li, X.
    Sahoo, N.
    Zhang, X.
    Gillin, M.
    Zhu, R. X.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S839 - S839