Prototype system for proton beam range measurement based on gamma electron vertex imaging

被引:14
|
作者
Lee, Han Rim [1 ]
Kim, Sung Hun [2 ]
Park, Jong Hoon [2 ]
Jung, Won Gyun [3 ]
Lim, Hansang [4 ]
Kim, Chan Hyeong [2 ]
机构
[1] Korea Atom Energy Res Inst, Neutron Utilizat Technol Div, 111,Daedeok Daero 989beon Gil, Daejeon 34057, South Korea
[2] Hanyang Univ, Dept Nucl Engn, Seoul 04763, South Korea
[3] Korean Inst Radiol & Med Sci, Heavy Ion Clin Res Div, Seoul 01812, South Korea
[4] Kwangwoon Univ, Dept Elect Convergence Engn, Seoul 01897, South Korea
基金
新加坡国家研究基金会;
关键词
Proton therapy; Proton dose monitoring; Beam range measurement; Prompt gamma; Gamma electron vertex imaging; ENERGY CALIBRATION; COMPTON CAMERA; SLIT CAMERA; VERIFICATION;
D O I
10.1016/j.nima.2017.03.022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In proton therapy, for both therapeutic effectiveness and patient safety, it is very important to accurately measure the proton dose distribution, especially the range of the proton beam. For this purpose, recently we proposed a new imaging method named gamma electron vertex imaging (GEVI), in which the prompt gammas emitting from the nuclear reactions of the proton beam in the patient are converted to electrons, and then the converted electrons are tracked to determine the vertices of the prompt gammas, thereby producing a 2D image of the vertices. In the present study, we developed a prototype GEVI system, including dedicated signal processing and data acquisition systems, which consists of a beryllium plate (= electron converter) to convert the prompt gammas to electrons, two double-sided silicon strip detectors (= hodoscopes) to determine the trajectories of those converted electrons, and a plastic scintillation detector (= calorimeter) to measure their kinetic energies. The system uses triple coincidence logic and multiple energy windows to select only the events from prompt gammas. The detectors of the prototype GEVI system were evaluated for electronic noise level, energy resolution, and time resolution. Finally, the imaging capability of the GEVI system was tested by imaging a Sr-90 beta source, a Co-60 gamma source, and a 45-MeV proton beam in a PMMA phantom. The overall results of the present study generally show that the prototype GEVI system can image the vertices of the prompt gammas produced by the proton nuclear interactions.
引用
收藏
页码:82 / 97
页数:16
相关论文
共 50 条
  • [1] Gamma electron vertex imaging and application to beam range verification in proton therapy
    Kim, Chan Hyeong
    Park, Jin Hyung
    Seo, Hee
    Lee, Han Rim
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 1001 - 1005
  • [2] Gamma electron vertex imaging for in-vivo beam-range measurement in proton therapy: Experimental results
    Kim, Chan Hyeong
    Lee, Han Rim
    Kim, Sung Hun
    Park, Jong Hoon
    Cho, Sungkoo
    Jung, Won Gyun
    [J]. APPLIED PHYSICS LETTERS, 2018, 113 (11)
  • [3] Upgrade of gamma electron vertex imaging system for high-performance range verification in pencil beam scanning proton therapy
    Kim, Sung Hun
    Jeong, Jong Hwi
    Ku, Youngmo
    Jung, Jaerin
    Cho, Sungkoo
    Jo, Kwanghyun
    Kim, Chan Hyeong
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (03) : 1016 - 1023
  • [4] Proton Range Shift Verification by Using Gamma Electron Vertex Imaging (GEVI) System in Spot Scanning Proton Therapy
    Kim, S.
    Ku, Y.
    Jung, J.
    Kim, C.
    Jeong, J.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E167 - E167
  • [5] Gamma electron vertex imaging and application to beam range verification in proton therapy (vol 39, pg 1001, 2012)
    Kim, Chan Hyeong
    Park, Jin Hyung
    Seo, Hee
    Lee, Han Rim
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6523 - 6524
  • [6] Range shift verification in spot scanning proton therapy using gamma electron vertex imaging
    Kim, Sung Hun
    Jeong, Jong Hwi
    Ku, Youngmo
    Lee, Se Byeong
    Shin, Dongho
    Lim, Young Kyung
    Kim, Haksoo
    Kim, Chan Hyeong
    [J]. MEDICAL PHYSICS, 2024, 51 (03) : 1985 - 1996
  • [7] Performance prediction of gamma electron vertex imaging (GEVI) system for interfractional range shift detection in spot scanning proton therapy
    Kim, Sung Hun
    Jeong, Jong Hwi
    Ku, Youngmo
    Jung, Jaerin
    Kim, Chan Hyeong
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (06) : 2213 - 2220
  • [8] A New Aperture-Based Imaging System for Prompt-Gamma Range Verification of Proton Beam Therapy
    Ready, I.
    Pak, R.
    Mihailescu, L.
    Vetter, K.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3678 - 3678
  • [9] 3D prompt gamma imaging for proton beam range verification
    Draeger, E.
    Mackin, D.
    Peterson, S.
    Chen, H.
    Avery, S.
    Beddar, S.
    Polf, J. C.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03):
  • [10] Beam Profile Measurement of Electron Gun Prototype for NICA Collider Electron Cooling System
    M. I. Bryzgunov
    A. V. Bubley
    A. P. Denisov
    A. V. Petrozhitskiy
    V. B. Reva
    E. Urazov
    [J]. Physics of Particles and Nuclei Letters, 2023, 20 : 133 - 139