Graphical treatment simulation and automated collision detection for conformal and stereotactic radiotherapy treatment planning

被引:25
|
作者
Tsiakalos, MF [1 ]
Schrebmann, E [1 ]
Theodorou, K [1 ]
Kappas, C [1 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Rio 26500, Hellas, Greece
关键词
virtual simulation; collision detection; 3D conformal radiotherapy; treatment planning; room's eye view;
D O I
10.1118/1.1381552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to develop a "room's eye view" graphical simulation program with an automated collision detection option, to assist a treatment planning user to visualize the treatment setup checking at the same time the feasibility of his plan. The program simulates the treatment process using accurate three-dimensional graphical models of the gantry, table, and that of an average patient. This allows the use of any mechanical movement concerning the radiotherapy unit. The simulation of the mechanical movements and their limitations are according to IEC standards and thus compatible with any radiotherapy machine. Graphical methods for collision detection between the models guarantee speed and accuracy. The module simulates the treatment setup with accuracy better than 2 degrees for any tested case. When a collision takes place a warning message is displayed. In this paper a software tool is developed that can be used as a stand-alone program or embedded in any treatment planning system. The visualization of the treatment fields prior to treatment permits the geometric feasibility of the plan, thus adding one more step toward the automation of the treatment process. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1359 / 1363
页数:5
相关论文
共 50 条
  • [41] TREATMENT PLANNING: STEREOTACTIC TREATMENT TECHNIQUES
    Nill, Simeon
    RADIOTHERAPY AND BRACHYTHERAPY, 2009, : 107 - 112
  • [42] Introduction to radiotherapy with photon and electron beams and treatment planning from conformal radiotherapy to IMET
    Wilkens, Jan J.
    NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2007, 958 : 63 - 69
  • [43] Outcome-Driven Inverse Treatment Planning for Conformal Lymphoma Radiotherapy
    Modiri, A.
    Stick, L.
    Rechner, L.
    Bentzen, S.
    Vogelius, I.
    Specht, L.
    Sawant, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 3257 - 3258
  • [44] MONITOR UNIT CHECKING IN HETEROGENEOUS STEREOTACTIC BODY RADIOTHERAPY TREATMENT PLANNING
    Higgins, Patrick D.
    Adolfson, Troy
    Cho, L. Chinsoo
    Saxena, Rishik
    MEDICAL DOSIMETRY, 2011, 36 (03) : 255 - 263
  • [45] A memetic algorithm for body gamma knife stereotactic radiotherapy treatment planning
    Liang, Bin
    Liu, Bo
    Zhou, Fugen
    Guo, Bin
    Xu, Xuanang
    Kang, Jingbo
    Li, Jianguo
    Liu, Wei
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 436 - 439
  • [46] Accuracy of treatment planning system and delivery of dose in extracranial stereotactic radiotherapy
    Dawod, T.
    Werner, M.
    Bremer, M.
    Karstens, J. H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 105 - 106
  • [47] Stereotactic body radiotherapy for liver metastases based on functional treatment planning
    Fode, M. M.
    Petersen, J.
    Worm, E.
    Sorensen, M.
    Bak-Fredslund, K.
    Keiding, S.
    Hoyer, M.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S166 - S167
  • [48] Stereotactic conformation radiotherapy with three dimensional planning for the treatment of extracranial lesions
    Tanaka, Y
    Kawamori, J
    Hirayama, M
    Saito, T
    Itoh, H
    Endoh, Y
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 507 - 512
  • [49] Commissioning of a new treatment planning system for CyberKnife robotic stereotactic radiotherapy
    Jaccard, M.
    Perichon, N.
    Fargier-Voiron, M.
    Matzinger, O.
    Bulling, S.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1541 - S1542
  • [50] Single-Segment IMRT Treatment Planning for Stereotactic Body Radiotherapy
    Bloch, C.
    Baker, K.
    Bradley, J.
    MEDICAL PHYSICS, 2010, 37 (06)