Graphical treatment simulation and automated collision detection for conformal and stereotactic radiotherapy treatment planning

被引:25
|
作者
Tsiakalos, MF [1 ]
Schrebmann, E [1 ]
Theodorou, K [1 ]
Kappas, C [1 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Rio 26500, Hellas, Greece
关键词
virtual simulation; collision detection; 3D conformal radiotherapy; treatment planning; room's eye view;
D O I
10.1118/1.1381552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to develop a "room's eye view" graphical simulation program with an automated collision detection option, to assist a treatment planning user to visualize the treatment setup checking at the same time the feasibility of his plan. The program simulates the treatment process using accurate three-dimensional graphical models of the gantry, table, and that of an average patient. This allows the use of any mechanical movement concerning the radiotherapy unit. The simulation of the mechanical movements and their limitations are according to IEC standards and thus compatible with any radiotherapy machine. Graphical methods for collision detection between the models guarantee speed and accuracy. The module simulates the treatment setup with accuracy better than 2 degrees for any tested case. When a collision takes place a warning message is displayed. In this paper a software tool is developed that can be used as a stand-alone program or embedded in any treatment planning system. The visualization of the treatment fields prior to treatment permits the geometric feasibility of the plan, thus adding one more step toward the automation of the treatment process. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1359 / 1363
页数:5
相关论文
共 50 条
  • [31] Collision detection and avoidance during treatment planning
    Humm, JL
    Pizzuto, D
    Fleischman, E
    Mohan, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1101 - 1108
  • [32] A Treatment Planning Study of Stereotactic Body Radiotherapy for Atrial Fibrillation
    Xia, Ping
    Kotecha, Rupesh
    Sharma, Naveen
    Andrews, Martin
    Stephans, Kevin L.
    Oberti, Carlos
    Lin, Sara
    Wazni, Oussama
    Tchou, Patrick
    Saliba, Walid I.
    Suh, John
    CUREUS, 2016, 8 (07):
  • [33] Four-dimensional treatment planning for stereotactic body radiotherapy
    Guckenberger, Matthias
    Wilbert, Juergen
    Krieger, Thomas
    Richter, Anne
    Baier, Kurt
    Meyer, Juergen
    Flentje, Michael
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01): : 276 - 285
  • [34] Interactive visual guidance for automated stereotactic radiosurgery treatment planning
    Ripsman, Danielle A.
    Aleman, Dionne M.
    Ghobadi, Kimia
    EXPERT SYSTEMS WITH APPLICATIONS, 2015, 42 (21) : 8337 - 8348
  • [35] Automated testing platform for radiotherapy treatment planning scripts
    Lucido, Joseph John
    Shiraishi, Satomi
    Seetamsetty, Srinivas
    Ellerbusch, David C. C.
    Antolak, John A. A.
    Moseley, Douglas J. J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (01):
  • [36] An automated treatment planning portfolio for whole breast radiotherapy
    Baroudi, Hana
    Che Fru, Leonard
    Schofield, Deborah
    Roniger, Dominique L.
    Nguyen, Callistus
    Hancock, Donald
    Chung, Christine
    Beadle, Beth M.
    Gifford, Kent A.
    Netherton, Tucker
    Niedzielski, Joshua S.
    Melancon, Adam
    Muruganandham, Manickam
    Khan, Meena
    Shaitelman, Simona F.
    Shete, Sanjay
    Murina, Patricia
    Venencia, Daniel
    Thengumpallil, Sheeba
    Vrieling, Conny
    Zhang, Joy
    Mitchell, Melissa P.
    Court, Laurence E.
    MEDICAL PHYSICS, 2025, 52 (03) : 1779 - 1788
  • [37] Automated and Clinically Optimal Treatment Planning for Cancer Radiotherapy
    Zarepisheh, Masoud
    Hong, Linda
    Zhou, Ying
    Huang, Qijie
    Yang, Jie
    Jhanwar, Gourav
    Pham, Hai D.
    Dursun, Pinar
    Zhang, Pengpeng
    Hunt, Margie A.
    Mageras, Gig S.
    Yang, Jonathan T.
    Yamada, Yoshiya
    Deasy, Joseph O.
    INFORMS JOURNAL ON APPLIED ANALYTICS, 2022, 52 (01): : 69 - 89
  • [38] Evaluation of An Automated Treatment Planning Verification System for Intensity-Modulated Radiotherapy Treatment Planning
    Xiao, L.
    Yin, Y.
    Tong, L. Xiu
    MEDICAL PHYSICS, 2017, 44 (06) : 2897 - 2897
  • [39] Dosimetric consequences of rotational setup errors with direct simulation in a treatment planning system for fractionated stereotactic radiotherapy
    Peng, Jean L.
    Liu, Chihray
    Chen, Yu
    Amdur, Robert J.
    Vanek, Kenneth
    Li, Jonathan G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (03): : 61 - 70
  • [40] Intensity-modulated stereotactic radiotherapy vs. stereotactic conformal radiotherapy for the treatment of meningioma located predominantly in the skull base
    Baumert, BG
    Norton, IA
    Davis, JB
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (02): : 580 - 592