Graphical treatment simulation and automated collision detection for conformal and stereotactic radiotherapy treatment planning

被引:25
|
作者
Tsiakalos, MF [1 ]
Schrebmann, E [1 ]
Theodorou, K [1 ]
Kappas, C [1 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Rio 26500, Hellas, Greece
关键词
virtual simulation; collision detection; 3D conformal radiotherapy; treatment planning; room's eye view;
D O I
10.1118/1.1381552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to develop a "room's eye view" graphical simulation program with an automated collision detection option, to assist a treatment planning user to visualize the treatment setup checking at the same time the feasibility of his plan. The program simulates the treatment process using accurate three-dimensional graphical models of the gantry, table, and that of an average patient. This allows the use of any mechanical movement concerning the radiotherapy unit. The simulation of the mechanical movements and their limitations are according to IEC standards and thus compatible with any radiotherapy machine. Graphical methods for collision detection between the models guarantee speed and accuracy. The module simulates the treatment setup with accuracy better than 2 degrees for any tested case. When a collision takes place a warning message is displayed. In this paper a software tool is developed that can be used as a stand-alone program or embedded in any treatment planning system. The visualization of the treatment fields prior to treatment permits the geometric feasibility of the plan, thus adding one more step toward the automation of the treatment process. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1359 / 1363
页数:5
相关论文
共 50 条
  • [21] Treatment planning of stereotactic radiotherapy for solitary lung tumor
    Takayama, K
    Nagata, Y
    Negoro, Y
    Mizowaki, T
    Sakamoto, T
    Sakamoto, M
    Aoki, T
    Yano, S
    Koga, S
    Hiraoka, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05): : 1565 - 1571
  • [22] MRI simulation for radiotherapy treatment planning
    Devic, Slobodan
    MEDICAL PHYSICS, 2012, 39 (11) : 6701 - 6711
  • [23] CT simulation for radiotherapy treatment planning
    Aird, EGA
    Conway, J
    BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (900): : 937 - 949
  • [24] Towards automated treatment planning for robotic stereotactic radiosurgery
    Nachbar, M.
    Acker, G.
    Senger, C.
    Mauersberger, K.
    Schild, R.
    Kuschke, W.
    Zips, D.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1340 - S1341
  • [25] Automated Determination of Beans Arrangement Based on Similar Cases in Radiotherapy Treatment Planning Database for Lung Stereotactic Body Radiotherapy
    Magome, T.
    Arimura, H.
    Shioyama, Y.
    Tokunaga, C.
    Nakamura, K.
    Anai, S.
    Honda, H.
    Ohki, M.
    Toyofuku, F.
    Hirata, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S860 - S861
  • [26] Comparison of dose distribution of three-dimensional conformal treatment planning and stereotactic radiotherapy for large intracranial lesions
    Yongvithisatid, P
    Pirabul, R
    Tannanonta, C
    Ua-apisitwong, S
    Dhanachai, M
    Kraiphibul, P
    Laothamatas, J
    Theerapancharoen, V
    Asavaphatiboon, S
    Assavaprathuangkul, P
    Boonpitak, K
    RADIOSURGERY, VOL 4, 2002, 4 : 245 - 250
  • [27] Treatment planning comparison of fractionated stereotactic radiotherapy, 3D conformal radiotherapy, and helical tomotherapy for benign tumours in the base of skull
    Cheung, A.
    Malone, S.
    Szanto, J.
    Clark, B.
    MacPherson, M.
    Nyiri, B.
    Fox, G.
    Montgomery, L.
    Carty, K.
    Deshaies, Y.
    Zohr, R.
    Spaans, J.
    RADIOTHERAPY AND ONCOLOGY, 2006, 80 : S27 - S28
  • [28] Optimization of beam-orientations in conformal radiotherapy treatment planning
    Rowbottom, CG
    MEDICAL PHYSICS, 1999, 26 (07) : 1406 - 1406
  • [29] Tabu search: An automatic treatment planning algorithm for conformal radiotherapy
    Gilio, JP
    MEDICAL PHYSICS, 1998, 25 (05) : 796 - 796
  • [30] Fully-automatic treatment planning for prostate conformal radiotherapy
    Meng, J
    Wilke, D
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S141 - S142