MONITOR UNIT CHECKING IN HETEROGENEOUS STEREOTACTIC BODY RADIOTHERAPY TREATMENT PLANNING

被引:3
|
作者
Higgins, Patrick D. [1 ]
Adolfson, Troy
Cho, L. Chinsoo
Saxena, Rishik
机构
[1] Univ Minnesota, Dept Therapeut Radiol Radiat Oncol, Sch Med, Minneapolis, MN 55455 USA
关键词
SBRT; Dose verification; Density effects; VIVO DIODE DOSIMETRY; IMRT; ALGORITHMS; ACCURACY;
D O I
10.1016/j.meddos.2010.04.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Treatment of lung cancer using very-high-dose fractionation in small fields requires well-tested dose modeling, a method for density-averaging compound targets constructed from different parts of the breathing cycle, and monitor unit verification of the heterogeneity-corrected treatment plans. The quality and safety of each procedure are dependent on these factors. We have evaluated the dosimetry of our first 26 stereotactic body radiotherapy (SBRT) patients, including 260 treatment fields, planned with the Pinnacle treatment planning system. All targets were combined from full expiration and inspiration computed tomography scans and planned on the normal respiration scan with 6-MV photons. Combined GTVs (cGTVs) have been density-averaged in different ways for comparison of the effect on total monitor units. In addition, we have compared planned monitor units against hand calculations using 2 classic ID correction methods: (1) effective attenuation and (2) ratio of Tissue-Maximum Ratios (TMRs) to determine the range of efficacy of simple verification methods over difficult-to-perform measurements. Different methods of density averaging for combined targets have been found to have minimal impact on total dose as evidenced by the range of total monitor units generated for each method. Nondensity-corrected treatment plans for the same fields were found to require about 8% more monitor units on average. Hand calculations, using the effective attenuation method were found to agree with Pinnacle calculations for nonproblematic fields to within +/-10% for >95% of the fields tested. The ratio of TMRs method was found to be unacceptable. Reasonable choices for density-averaging of cGTVs using full inspiration/expiration scans should not strongly affect the planning dose. Verification of planned monitor units, as a check for problematic fields, can be done for 6-MV fields with simple 1D effective attenuation-corrected hand calculations. (C) 2011 American Association of Medical Dosimetrists.
引用
收藏
页码:255 / 263
页数:9
相关论文
共 50 条
  • [1] Monitor Unit-Efficient Planning for Stereotactic Body Radiation Therapy and Stereotactic Radiosurgery
    Manger, R.
    Yock, A.
    Hoopes, D. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E649 - E650
  • [2] A Treatment Planning Study of Stereotactic Body Radiotherapy for Atrial Fibrillation
    Xia, Ping
    Kotecha, Rupesh
    Sharma, Naveen
    Andrews, Martin
    Stephans, Kevin L.
    Oberti, Carlos
    Lin, Sara
    Wazni, Oussama
    Tchou, Patrick
    Saliba, Walid I.
    Suh, John
    CUREUS, 2016, 8 (07):
  • [3] Four-dimensional treatment planning for stereotactic body radiotherapy
    Guckenberger, Matthias
    Wilbert, Juergen
    Krieger, Thomas
    Richter, Anne
    Baier, Kurt
    Meyer, Juergen
    Flentje, Michael
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01): : 276 - 285
  • [4] Automated treatment planning for liver cancer stereotactic body radiotherapy
    He, Ling
    Peng, Xingchen
    Chen, Na
    Wei, Zhigong
    Wang, Jingjing
    Liu, Yingtong
    Xiao, Jianghong
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2023, 25 (11): : 3230 - 3240
  • [5] Automated treatment planning for liver cancer stereotactic body radiotherapy
    Ling He
    Xingchen Peng
    Na Chen
    Zhigong Wei
    Jingjing Wang
    Yingtong Liu
    Jianghong Xiao
    Clinical and Translational Oncology, 2023, 25 : 3230 - 3240
  • [6] A memetic algorithm for body gamma knife stereotactic radiotherapy treatment planning
    Liang, Bin
    Liu, Bo
    Zhou, Fugen
    Guo, Bin
    Xu, Xuanang
    Kang, Jingbo
    Li, Jianguo
    Liu, Wei
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 436 - 439
  • [7] Stereotactic body radiotherapy for liver metastases based on functional treatment planning
    Fode, M. M.
    Petersen, J.
    Worm, E.
    Sorensen, M.
    Bak-Fredslund, K.
    Keiding, S.
    Hoyer, M.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S166 - S167
  • [8] Single-Segment IMRT Treatment Planning for Stereotactic Body Radiotherapy
    Bloch, C.
    Baker, K.
    Bradley, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [9] Effect of Acuros XB algorithm on monitor units for stereotactic body radiotherapy planning of lung cancer
    Khan, Rao F.
    Villarreal-Barajas, Eduardo
    Lau, Harold
    Liu, Hong-Wei
    MEDICAL DOSIMETRY, 2014, 39 (01) : 83 - 87
  • [10] A treatment planning system for stereotactic radiotherapy
    Benassi, M
    Gentile, FP
    Begnozzi, L
    Chiatti, L
    Malaspina, F
    Carpino, S
    ANTICANCER RESEARCH, 1995, 15 (5B) : 2239 - 2245