Accuracy of complete-arch intraoral scans based on confocal microscopy versus optical triangulation: A comparative in vitro study

被引:22
|
作者
Waldecker, Moritz [1 ]
Rues, Stefan [1 ]
Rammelsberg, Peter [1 ]
Boemicke, Wolfgang [1 ]
机构
[1] Heidelberg Univ, Dept Prosthodont, Heidelberg Univ Hosp, Heidelberg, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2021年 / 126卷 / 03期
关键词
DIGITAL IMPRESSION TECHNIQUE; PATIENTS PREFERENCES; MARGINAL FIT; SINGLE-UNIT; CROWNS; TIME; THICKNESS; ZIRCONIA; SYSTEMS;
D O I
10.1016/j.prosdent.2020.04.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Fully digital dentistry is contingent on an accurate digital scan of the complete arch; however, the dimensional accuracy of different scanners for digitizing a complete arch is unclear. Purpose. The purpose of this in vitro study was to compare the accuracy of 2 intraoral scanners, TRIOS 3 (TR) and CEREC Omnicam (OC). Accuracy was assessed from changes to reference distances defined along the complete arch of a reference cast including 3 precision balls and 3 prepared teeth. The local accuracy (trueness and precision) of the scanned surface of each prepared tooth was also assessed. Material and methods. Each intraoral scanner was used to scan a metal mandibular reference cast 20 times in a randomized sequence. The complete dental arch of a mandible in which the second left premolar was missing contained 2 prepared teeth, the first left premolar (LP) and the first left molar (LM) to accommodate a fixed partial denture (FPD) with complete crowns. The arch also contained an inlay preparation on the right second premolar (RP). Stainless-steel precision balls (ball centers P1, P2, and P3), which were welded onto the left second molar (P1), the incisal contact point of the central incisors (P3), and the right first molar (P2), were used to determine dimensional changes over the complete arch. Powder (CEREC Optispray) was applied to the reference cast to reduce reflections. Deviations between the reference cast (digitized with high precision before the tests) and the intraoral scans were calculated using Matlab R2015a and Geomagic Design X. To evaluate dimensional changes, the centers of the balls were determined, and their absolute changes in distance (AP1P2, AP1P3, and AP2P3) were calculated. To calculate accuracy (trueness and precision) in relation to the prepared teeth, the mesh deviation between the intraoral scans and the superimposed reference teeth was determined. The data were statistically analyzed by using a nonparametric rank-based 2-way repeated-measures ANOVA, and differences in least square means for pairwise comparisons were calculated (a=.05). Results. The following mean absolute changes in distance were determined: Delta P1P2, TR: 74.4 mu m, OC: 119.6 mu m; Delta P1P3, TR: 24.7 mu m, OC: 17.2 gm; Delta P2P3, TR: 68.6 mu m, OC: 41.2 gm. The scanner did not have a statistically significant effect (P=.118) for distance, and the different distances differed significantly from each other (P<.001). Both scanners provided results acceptable for the fabrication of inlays and short-span FPDs. A complete-crown scan was more accurate than an inlay scan (P<.001). Accuracy and precision were better for TR than for OC (P<.001). Conclusions. With maximum discrepancies of 192.5 to 294.6 gm across the dental arch, complete-arch scans cannot yet be recommended for the fabrication of long-span FPDs.
引用
下载
收藏
页码:414 / 420
页数:7
相关论文
共 50 条
  • [21] Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study
    Cakmak, Gulce
    Yilmaz, Hakan
    Santos, Alejandro Trevino
    Kokat, Ali Murat
    Yilmaz, Burak
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 419 - 426
  • [22] Accuracy of digital complete-arch, multi-implant scans made in the edentulous jaw with gingival movement simulation: An in vitro study
    Knechtle, Nathalie
    Wiedemeier, Daniel
    Mehl, Albert
    Ender, Andreas
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 468 - 478
  • [23] Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete-Arch Implant Impression: An In Vitro Study
    Fu, Xiao-Jiao
    Liu, Min
    Shi, Jun-Yu
    Deng, Ke
    Lai, Hong-Chang
    Gu, Wen
    Zhang, Xiao-Meng
    CLINICAL ORAL IMPLANTS RESEARCH, 2024,
  • [24] Error propagation from intraoral scanning to additive manufacturing of complete-arch dentate models: An in vitro study
    Auskalnis, Liudas
    Akulauskas, Mykolas
    Jegelevicius, Darius
    Simonaitis, Tomas
    Rutkunas, Vygandas
    JOURNAL OF DENTISTRY, 2022, 121
  • [25] Evaluation of the accuracy of seven intraoral scanners for the full dentate and partially edentulous complete-arch mandibular casts: An in vitro comparison
    Wang, Xin
    Zhang, Fang
    Ma, Dan
    Ye, Xiaolan
    Zheng, Xiaojuan
    Ren, Ruifang
    Ren, Nan
    Bai, Shizhu
    HELIYON, 2024, 10 (10)
  • [26] Accuracy of complete-arch digital implant impression with or without scanbody splinting: An in vitro study
    Pozzi, Alessandro
    Arcuri, Lorenzo
    Lio, Fabrizio
    Papa, Andrea
    Nardi, Alessandra
    Londono, Jimmy
    JOURNAL OF DENTISTRY, 2022, 119
  • [27] Studying the Optical 3D Accuracy of Intraoral Scans: An In Vitro Study
    Amornvit, Pokpong
    Sanohkan, Sasiwimol
    Peampring, Chaimongkon
    JOURNAL OF HEALTHCARE ENGINEERING, 2020, 2020 (2020)
  • [28] Effect of novel prefabricated auxiliary devices attaching to scan bodies on the accuracy of intraoral scanning of complete-arch with multiple implants: An in-vitro study
    Wu, Hio Kuan
    Wang, Jing
    Chen, Guanhui
    Huang, Xiaoqiong
    Deng, Feilong
    Li, Yiming
    JOURNAL OF DENTISTRY, 2023, 138
  • [29] Learning curve of digital intraoral optical scanning for complete arch: an in vitro study
    Lio, F.
    Carosi, P.
    Mazzetti, V
    Arcuri, C.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2022, 36 (02): : 19 - 27
  • [30] Evaluating the influence of palate scanning on the accuracy of complete-arch digital impressions-An in vitro study
    Schmalzl, Judit
    Keskeny, Gyorgy Arpad
    Hermann, Peter
    Pal, Adrienn
    Geczi, Zoltan
    Borbely, Judit
    Roth, Ivett
    JOURNAL OF DENTISTRY, 2024, 145