Accuracy of complete-arch intraoral scans based on confocal microscopy versus optical triangulation: A comparative in vitro study

被引:22
|
作者
Waldecker, Moritz [1 ]
Rues, Stefan [1 ]
Rammelsberg, Peter [1 ]
Boemicke, Wolfgang [1 ]
机构
[1] Heidelberg Univ, Dept Prosthodont, Heidelberg Univ Hosp, Heidelberg, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2021年 / 126卷 / 03期
关键词
DIGITAL IMPRESSION TECHNIQUE; PATIENTS PREFERENCES; MARGINAL FIT; SINGLE-UNIT; CROWNS; TIME; THICKNESS; ZIRCONIA; SYSTEMS;
D O I
10.1016/j.prosdent.2020.04.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Fully digital dentistry is contingent on an accurate digital scan of the complete arch; however, the dimensional accuracy of different scanners for digitizing a complete arch is unclear. Purpose. The purpose of this in vitro study was to compare the accuracy of 2 intraoral scanners, TRIOS 3 (TR) and CEREC Omnicam (OC). Accuracy was assessed from changes to reference distances defined along the complete arch of a reference cast including 3 precision balls and 3 prepared teeth. The local accuracy (trueness and precision) of the scanned surface of each prepared tooth was also assessed. Material and methods. Each intraoral scanner was used to scan a metal mandibular reference cast 20 times in a randomized sequence. The complete dental arch of a mandible in which the second left premolar was missing contained 2 prepared teeth, the first left premolar (LP) and the first left molar (LM) to accommodate a fixed partial denture (FPD) with complete crowns. The arch also contained an inlay preparation on the right second premolar (RP). Stainless-steel precision balls (ball centers P1, P2, and P3), which were welded onto the left second molar (P1), the incisal contact point of the central incisors (P3), and the right first molar (P2), were used to determine dimensional changes over the complete arch. Powder (CEREC Optispray) was applied to the reference cast to reduce reflections. Deviations between the reference cast (digitized with high precision before the tests) and the intraoral scans were calculated using Matlab R2015a and Geomagic Design X. To evaluate dimensional changes, the centers of the balls were determined, and their absolute changes in distance (AP1P2, AP1P3, and AP2P3) were calculated. To calculate accuracy (trueness and precision) in relation to the prepared teeth, the mesh deviation between the intraoral scans and the superimposed reference teeth was determined. The data were statistically analyzed by using a nonparametric rank-based 2-way repeated-measures ANOVA, and differences in least square means for pairwise comparisons were calculated (a=.05). Results. The following mean absolute changes in distance were determined: Delta P1P2, TR: 74.4 mu m, OC: 119.6 mu m; Delta P1P3, TR: 24.7 mu m, OC: 17.2 gm; Delta P2P3, TR: 68.6 mu m, OC: 41.2 gm. The scanner did not have a statistically significant effect (P=.118) for distance, and the different distances differed significantly from each other (P<.001). Both scanners provided results acceptable for the fabrication of inlays and short-span FPDs. A complete-crown scan was more accurate than an inlay scan (P<.001). Accuracy and precision were better for TR than for OC (P<.001). Conclusions. With maximum discrepancies of 192.5 to 294.6 gm across the dental arch, complete-arch scans cannot yet be recommended for the fabrication of long-span FPDs.
引用
收藏
页码:414 / 420
页数:7
相关论文
共 50 条
  • [41] Digital workflow: In vitro accuracy of 3D printed casts generated from complete-arch digital implant scans (vol 124, pg 589, 2020)
    Papaspyridakos, P.
    Chen, Y-W
    Alshawaf, B.
    Kang, K.
    Finkelman, M.
    Chronopoulos, V
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06):
  • [42] Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
    Di Fiore, Adolfo
    Graiff, Lorenzo
    Savio, Gianpaolo
    Granata, Stefano
    Basilicata, Michele
    Bollero, Patrizio
    Meneghello, Roberto
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (08)
  • [43] Effect of pulp chamber depth on the accuracy of endocrown scans made with different intraoral scanners versus an industrial scanner: An in vitro study
    Gurpinar, Bahar
    Tak, Onjen
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 430 - 437
  • [44] Effect of implant scan body geometric modi fi cations on the trueness and scanning time of complete arch intraoral implant digital scans: An in vitro study
    Lawand, Ghida
    Ismail, Yara
    Revilla-Leon, Marta
    Tohme, Hani
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1189 - 1197
  • [45] Comparative analysis on efficiency and accuracy of parallel confocal microscopy and three-dimensional in motion video with triangulation technology-based intraoral scanner under influence of moisture and mouth opening - A crossover clinical trial
    Sindhu, J. Senthamil
    Maiti, Subhabrata
    Nallaswamy, Deepak
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2023, 23 (03): : 234 - 243
  • [46] Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material versus intraoral scanner
    Rcch-Ortega, Cristina
    Fernandez-Estevan, Lucia
    Fernanda Sola-Ruiz, Ma
    Agustin-Panadero, Ruben
    Labaig-Rueda, Carlos
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2019, 24 (01): : E89 - E95
  • [47] In vitro comparative study between complete arch conventional implant impressions and digital implant scans with scannable pick-up impression copings
    Conejo, Julian
    Yoo, Thomas H.
    Atria, Pablo J.
    Fraiman, Howard
    Blatz, Markus B.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03): : 475e1 - 475e7
  • [48] Accuracy of photogrammetric imaging versus conventional impressions for complete arch implant-supported fixed dental prostheses: A comparative clinical study
    Zhang, Yi-Jie
    Qian, Shu-Jiao
    Lai, Hong-Chang
    Shi, Jun-Yu
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (02): : 212 - 218
  • [49] Accuracy of traditional open-tray impression, stereophotogrammetry, and intraoral scanning with prefabricated aids for implant-supported complete arch prostheses with different implant distributions: An in vitro study
    Liu, Min
    Fu, Xiao-Jiao
    Lai, Hong-Chang
    Shi, Jun-Yu
    Liu, Bei-Lei
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (03):
  • [50] En-face Optical Coherence Tomography as a Novel Tool for Exploring the Ocular Surface: A Pilot Comparative Study to Conventional B-Scans and in Vivo Confocal Microscopy
    Hassani, Rachid Tahiri Joutei
    Liang, Hong
    El Sanharawi, Mohamed
    Brasnu, Emmanuelle
    Kallel, Sofiene
    Labbe, Antoine
    Baudouin, Christophe
    OCULAR SURFACE, 2014, 12 (04): : 285 - 306