Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material versus intraoral scanner

被引:26
|
作者
Rcch-Ortega, Cristina [1 ]
Fernandez-Estevan, Lucia [1 ]
Fernanda Sola-Ruiz, Ma [1 ]
Agustin-Panadero, Ruben [1 ]
Labaig-Rueda, Carlos [1 ]
机构
[1] Univ Valencia, Fac Med & Dent, Dept Dent Med, Valencia, Spain
来源
关键词
Digital workflow; full arch scan; intraoral scanner; CAD/CAM; polyether impression; accuracy; TITANIUM; SYSTEM; FIT;
D O I
10.4317/medoral.22822
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The aim of this study was to compare a conventional technique (elastomeric impression material - EIM) and a digital technique (scanner digital model - SDM) on a six-analog master model (MM) to determine which was the most exact. Material and Methods: Twenty impressions were taken of a master model (EIM) and twenty scanned impressions (SDM) (True Definition). A coordinate measuring machine (CMM) was used to measure the distances between adjacent analogues (1-2, 2-3, 3-4, 4-5, 5-6), intermittently positioned analogues (1-4, 3-6) and the most distal (1-6). Reference values were established from the master model, which were compared with the two impression techniques. The significance level was established as 5% (p<0.05). Results: The precision of each technique was compared with MM. For adjacent analogues (1-2), no significant differences were found between EIM-MM (p=0,146). For intermittently positioned analogues (1-4), SDM did not show significant differences with MM (p=0.255). For the distance between distal analogues (1-6), significant differences were found between both techniques and MM (p=0.001). Conclusions: In a clinical situation with < three implants. EIM is more exact than SDM, but in cases of four implants SDM is more exact. For rehabilitations (> four implants), neither technique can be considered accurate although error falls within the tolerance limits established in the literature (30-150 mu m).
引用
收藏
页码:E89 / E95
页数:7
相关论文
共 50 条
  • [1] Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies
    Albanchez-Gonzalez, Maria Isabel
    Brinkmann, Jorge Cortes-Breton
    Pelaez-Rico, Jesus
    Lopez-Suarez, Carlos
    Rodriguez-Alonso, Veronica
    Suarez-Garcia, Maria Jesus
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (04)
  • [2] A comparative analysis of the accuracy of different direct impression techniques for multiple implants
    Ongul, D.
    Gokcen-Rohlig, B.
    Sermet, B.
    Keskin, H.
    [J]. AUSTRALIAN DENTAL JOURNAL, 2012, 57 (02) : 184 - 189
  • [3] Accuracy of digital auricular impression using intraoral scanner versus conventional impression technique for ear rehabilitation: A controlled clinical trial
    Dohiem, Mohamed M.
    Emam, Nourhan S.
    Abdallah, Mohamed Farouk
    Abdelaziz, Medhat Sameh
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2022, 75 (11): : 4254 - 4263
  • [4] COMPARISON OF THE ACCURACY OF INTRAORAL SCANNING AND CONVENTIONAL IMPRESSION TECHNIQUES ON IMPLANTS: A REVIEW
    Arcuri, L.
    Lorenzi, C.
    Vanni, A.
    Bianchi, N.
    Dolci, A.
    Arcuri, C.
    [J]. JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2020, 34 : 89 - 97
  • [5] Comparative Evaluation of the Rigidity and Accuracy of Different Elastomeric Impression Materials with Open Tray Implant Level Impression Technique-An In vitro Study
    Aidasani, Ashwin N.
    Jain, Shailesh
    Hassan, Sahba
    Sharma, Anu
    Shanthi, C.
    Fere, Sandeep
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1262 - S1265
  • [6] Comparative Analysis of Three Different Impression Techniques for Impression Defects and Dimensional Accuracy Using a Digital Intraoral Scanner for Fixed Partial Dentures: An In Vivo Study
    Khatuja, Neha G.
    Katiyar, Pratibha
    Tarannum, Fauzia
    Pandey, Kaushik Kumar
    Katiyar, Abhishek Kumar
    Afzal, Zoya
    Ali, Aman
    Roy, Ispita
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [7] Dimensional accuracy of vinyl polyetherand polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants
    Rajendran, Rohini
    Chander, N. Gopi
    Anitha, Kuttae Vishwanathan
    Muthukumar, Balasubramanian
    [J]. EUROPEAN ORAL RESEARCH, 2021, 55 (02) : 54 - 59
  • [8] Comparison of the accuracy for three dental impression techniques and index: An in vitro study
    de Avila, Erica Dorigatti
    Borelli Barros, Luiz Antonio
    Del'Acqua, Marcelo Antonialli
    Castanharo, Sabrina Maria
    Mollo, Francisco de Assis, Jr.
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2013, 57 (04) : 268 - 274
  • [9] A Comparative Study to Assess Accuracy of Casts Prepared using Direct Impression Technique with and without Splinting of Multiple Dental Implants Utilising Two Different Splinting and Impression Materials
    Karia, Milap
    Vaghela, Ishita
    Ajmera, Hardik
    Detroja, Kishan
    Vasant, Jill D.
    Sharma, Devanshi
    Kumar, Amit
    Badiyani, Bhumika Kamal
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S944 - S947
  • [10] Accuracy of Implant Level Intraoral Scanning and Photogrammetry Impression Techniques in a Complete Arch with Angled and Parallel Implants: An In Vitro Study
    Tohme, Hani
    Lawand, Ghida
    Eid, Rita
    Ahmed, Khaled E.
    Salameh, Ziad
    Makzoume, Joseph
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (21):