Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T

被引:67
|
作者
Wang, Z
Wang, JJ
Connick, TJ
Wetmore, GS
Detre, JA
机构
[1] Univ Penn, Sch Med, Ctr Funct Neuroimaging, Dept Neurol, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Med, Dept Radiol, Philadelphia, PA 19104 USA
关键词
ASL perfusion imaging; parallel imaging; GRAPPA; CBF; SNR;
D O I
10.1002/mrm.20574
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was to assess the feasibility and efficacy of using an array coil and parallel imaging in continuous arterial spin labeling (CASL) perfusion MRI. An 8-channel receive-only array head coil was used in conjunction with a surrounding detunable volume transmit coil. The signal to noise ratio (SNR), temporal stability, cerebral blood flow (CBF), and perfusion image coverage were measured from steady state CASL scans using: a standard volume coil, array coil, and array coil with 2- and 3-fold accelerated parallel imaging. Compared to the standard volume coil, the array coil provided 3 times the average SNR increase and higher temporal stability for the perfusion weighted images, even with threefold acceleration. Although perfusion images of the array coil were affected by the inhomogeneous coil sensitivities, this effect was invisible in the quantitative CBF images, which showed highly reproducible perfusion values compared to the standard volume coil. The unfolding distortions of parallel imaging were suppressed in the perfusion images by pairwise subtraction, though they sharply degraded the raw EPI images. Moreover, parallel imaging provided the potential of acquiring more slices due to the shortened acquisition time and improved coverage in brain regions with high static field inhomogeneity. Such results highlight the potential utility of array coils and parallel imaging in ASL perfusion MRI.
引用
收藏
页码:732 / 737
页数:6
相关论文
共 50 条
  • [41] Simulation Comparison of Birdcage Coil and Metamaterial Liner for MRI at 3T and 4.7T
    Maunder, Adam
    De Zanche, Nicola
    Iyer, Ashwin K.
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020, : 1067 - 1070
  • [42] Simulation Comparison of Birdcage Coil and Metamaterial Liner for MRI at 3T and 4.7T
    Maunder, Adam
    De Zanche, Nicola
    Iyer, Ashwin K.
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020,
  • [43] Simulation Comparison of Birdcage Coil and Metamaterial Liner for MRI at 3T and 4.7T
    Maunder, Adam
    De Zanche, Nicola
    Iyer, Ashwin K.
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020,
  • [44] Prostate Cancer: Added Value of Subtraction Dynamic Imaging in 3T Magnetic Resonance Imaging with a Phased-array Body Coil
    Yu, Jeong-Sik
    Chung, Jae-Joon
    Hong, Soon Won
    Chung, Byung Ha
    Kim, Joo Hee
    Kim, Ki Whang
    YONSEI MEDICAL JOURNAL, 2008, 49 (05) : 765 - 774
  • [45] Imaging adult zebrafish brain structures using micro-fabricated RF coil on 3T MRI system
    Hsieh, Meng-Chi
    Kuo, Li-Wei
    Wu, Edzer
    Chen, Jyh-Horng
    2007 JOINT MEETING OF THE 6TH INTERNATIONAL SYMPOSIUM ON NONINVASIVE FUNCTIONAL SOURCE IMAGING OF THE BRAIN AND HEART AND THE INTERNATIONAL CONFERENCE ON FUNCTIONAL BIOMEDICAL IMAGING, 2007, : 177 - 179
  • [46] Peripheral perfusion index measured using magnetohydrodynamic voltages in 3T MRI
    Thomas S Gregory
    Ehud J Schmidt
    Shelley H Zhang
    Jonathan R Murrow
    Zion T Tse
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [47] Expected and Unexpected Findings After Prostatectomy: 3T MRI With Surface and Endorectal Coil
    Taneja, R.
    Lee, J.
    Kolokythas, O.
    Dighe, M.
    Dubinsky, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [48] High Acceleration with a Rotating Radiofrequency Coil Array (RRFCA) in Parallel Magnetic Resonance Imaging (MRI)
    Li, Mingyan
    Jin, Jin
    Trakic, Adnan
    Liu, Feng
    Weber, Ewald
    Li, Yu
    Crozier, Stuart
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1098 - 1101
  • [49] A Dedicated 36-Channel Receive Array for Fetal MRI at 3T
    Chen, Qiaoyan
    Xie, Guoxi
    Luo, Chao
    Yang, Xing
    Zhu, Jin
    Lee, Jo
    Su, Shi
    Liang, Dong
    Zhang, Xiaoliang
    Liu, Xin
    Li, Ye
    Zheng, Hairong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (10) : 2290 - 2297
  • [50] Towards HCP-Style macaque connectomes: 24-Channel 3T multi -array coil, MRI sequences and preprocessing
    Autio, Joonas A.
    Glasser, Matthew F.
    Ose, Takayuki
    Donahue, Chad J.
    Bastiani, Matteo
    Ohno, Masahiro
    Kawabata, Yoshihiko
    Urushibata, Yuta
    Murata, Katsutoshi
    Nishigori, Kantaro
    Yamaguchi, Masataka
    Hori, Yuki
    Yoshida, Atsushi
    Go, Yasuhiro
    Coalson, Timothy S.
    Jbabdi, Saad
    Sotiropoulos, Stamatios N.
    Kennedy, Henry
    Smith, Stephen
    Van Essen, David C.
    Hayashi, Takuya
    NEUROIMAGE, 2020, 215