Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T

被引:67
|
作者
Wang, Z
Wang, JJ
Connick, TJ
Wetmore, GS
Detre, JA
机构
[1] Univ Penn, Sch Med, Ctr Funct Neuroimaging, Dept Neurol, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Med, Dept Radiol, Philadelphia, PA 19104 USA
关键词
ASL perfusion imaging; parallel imaging; GRAPPA; CBF; SNR;
D O I
10.1002/mrm.20574
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was to assess the feasibility and efficacy of using an array coil and parallel imaging in continuous arterial spin labeling (CASL) perfusion MRI. An 8-channel receive-only array head coil was used in conjunction with a surrounding detunable volume transmit coil. The signal to noise ratio (SNR), temporal stability, cerebral blood flow (CBF), and perfusion image coverage were measured from steady state CASL scans using: a standard volume coil, array coil, and array coil with 2- and 3-fold accelerated parallel imaging. Compared to the standard volume coil, the array coil provided 3 times the average SNR increase and higher temporal stability for the perfusion weighted images, even with threefold acceleration. Although perfusion images of the array coil were affected by the inhomogeneous coil sensitivities, this effect was invisible in the quantitative CBF images, which showed highly reproducible perfusion values compared to the standard volume coil. The unfolding distortions of parallel imaging were suppressed in the perfusion images by pairwise subtraction, though they sharply degraded the raw EPI images. Moreover, parallel imaging provided the potential of acquiring more slices due to the shortened acquisition time and improved coverage in brain regions with high static field inhomogeneity. Such results highlight the potential utility of array coils and parallel imaging in ASL perfusion MRI.
引用
收藏
页码:732 / 737
页数:6
相关论文
共 50 条
  • [31] A comparison of 3T MR imaging of the prostate with and without an endorectal coil
    Ischia, J.
    Co, S.
    Harris, A.
    Kozlowski, P.
    Jones, E.
    Chang, S.
    Goldenberg, L.
    BJU INTERNATIONAL, 2014, 113 : 119 - 120
  • [32] SNR Variability with Frontal Coil Plate Displacement in 3T Head MRI
    Mathieu, William
    Popovic, Milica
    Farivar, Reza
    2024 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC 2024, 2024, : 131 - 133
  • [33] Eight-channel transmit/receive body MRI coil at 3T
    Vernickel, P.
    Roeschmann, P.
    Findeklee, C.
    Luedeke, K.-M.
    Leussler, Ch.
    Overwag, J.
    Katscher, U.
    Graesslin, I.
    Schuenemann, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 381 - 389
  • [34] High resolution 3D CISS imaging at 3T with a hybrid phased array coil: Application to internal auditory canal imaging
    Ward, HA
    Bernstein, MA
    Witte, RJ
    Lane, JI
    Kocharian, A
    Polzin, JA
    RADIOLOGY, 2002, 225 : 549 - 549
  • [35] An eight-channel sodium/proton coil for brain MRI at 3T
    Lakshmanan, Karthik
    Brown, Ryan
    Madelin, Guillaume
    Qian, Yongxian
    Boada, Fernando
    Wiggins, Graham C.
    NMR IN BIOMEDICINE, 2018, 31 (02)
  • [36] A deep brain stimulation-conditioned RF coil for 3T MRI
    Kutscha, Nicolas
    Mahmutovic, Mirsad
    Bhusal, Bhumi
    Vu, Jasmine
    Chemlali, Chaimaa
    Hansen, Sam-Luca J. D.
    May, Markus W.
    Knake, Susanne
    Golestanirad, Laleh
    Keil, Boris
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 1411 - 1426
  • [37] Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction
    Lupo, Janine M.
    Lee, Michael C.
    Han, Eric T.
    Cha, Soonmee
    Chang, Susan M.
    Berger, Mitchel S.
    Nelson, Sarah J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (03) : 520 - 529
  • [38] Comparison of a 32-Channel Coil and a Six-Channel Coil for MRI of the Prostate at 3T
    Sammet, S.
    Wei, W.
    Reiss, B.
    Liang, J.
    Jia, G.
    Aguila, F.
    Choi, S.
    Knopp, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [39] Simulations of a birdcage coil B1+ field on a human body model for designing a 3T multichannel TMS/MRI head coil array
    de Lara, Lucia I. Navarro
    Rad, Laleh Golestani
    Makarov, Sergey N.
    Stockmann, Jason
    Wald, Lawrence L.
    Nummenmaa, Aapo
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4752 - 4755
  • [40] Feasibility of Specific Ventilation Imaging on a 3T MRI scanner
    O'Sullivan, C.
    Prisk, G. K.
    Nilsen, K.
    Mcintyre, R.
    Pontre, B.
    Dubowitz, D.
    Thompson, B.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60