Purpose: 4D CT is useful clinically for detailed abdominal and thoracic imaging over the course of the respiratory cycle. However, it usually delivers 10∼15 times more radiation dose to the patient as compared to the standard 3D CT, since multiple scans at each couch position are required to obtain the temporal information. In this work we propose a method to obtain high quality 4D CT with low tube current, hence reducing the radiation exposure of patients. Method and Materials: The improvement of the signal‐to‐noise ratio (SNR) of the CT image at a given phase was achieved by superposing the imaging information from other phases with the use of a deformable image registration model. To further reduce the statistical noise caused by low tube current, we developed a novel 4D penalized weighted least square (4D‐PWLS) method to smooth the data spatially and temporally. The method was validated by motion‐phantom and patient studies using a GE Discovery‐ST PET/CT scanner. A Varian RPM respiratory gating system was used to track the motion and to facilitate the phase binning of the 4D CT data. Results: We calculated the SNRs for both studies. The average SNR of 10 mA phantom images increased by more than three‐fold from 0.051 to 0.165 after the proposed 4D‐PWLS processing, without noticeable resolution loss. The patient images acquired at 90mA showed an increase from 2.204 to 4.558 for the end‐inspiration phase, and from 1.741 to 3.862 for the end‐expiration phase, respectively. By examining the subtraction images before and after processing, good edge preservation was also observed in the patient study. Conclusion: By appropriately utilizing the temporal information in 4D‐CT, the proposed method effectively suppresses the noise while preserving the resolution. The technique provides a useful way to reduce the patient dose during 4D CT and is thus valuable for 4D‐radiotherapy. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2094 / 2095
页数:2
相关论文
共 50 条
  • [41] Dose reduction for kilovotage cone-beam computed tomography in radiation therapy
    Wang, Jing
    Li, Tianfang
    Liang, Zhengrong
    Xing, Lei
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11): : 2897 - 2909
  • [42] Radiation Dose Reduction in Computed Tomography: Implementation of an Iterative Image Reconstruction Method
    Chartrand-Lefebvre, Carl
    Prosmanne, Odile
    Belair, Manon
    Therasse, Eric
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (04): : 386 - 386
  • [43] Radiation dose reduction for musculoskeletal computed tomography of the pelvis with preserved image quality
    Zabak, Elaina
    Omar, Hythem
    Boothe, Ethan
    Tenorio, Lulu
    Guild, Jeffrey
    Abbara, Suhny
    Chhabra, Avneesh
    SKELETAL RADIOLOGY, 2019, 48 (03) : 375 - 385
  • [44] Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality
    Geryes, Bouchra Habib
    Calmon, Raphael
    Khraiche, Diala
    Boddaert, Nathalie
    Bonnet, Damien
    Raimondi, Francesca
    EUROPEAN RADIOLOGY, 2016, 26 (07) : 2030 - 2038
  • [45] Radiation dose reduction for musculoskeletal computed tomography of the pelvis with preserved image quality
    Elaina Zabak
    Hythem Omar
    Ethan Boothe
    Lulu Tenorio
    Jeffrey Guild
    Suhny Abbara
    Avneesh Chhabra
    Skeletal Radiology, 2019, 48 : 375 - 385
  • [46] Reduction of radiation dose according to the type of technology used in cardiac computed tomography
    Courtis, Javier
    Copa Gallardo, Juan
    Dimitroff, Magdalena
    Gonzalez, Analia
    REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2020, 49 (02):
  • [47] Evolution of Coronary Computed Tomography Radiation Dose Reduction at a Tertiary Referral Center
    Ghoshhajra, Brian Burns
    Engel, Leif-Christopher
    Major, Gyoengyi Petra
    Goehler, Alexander
    Techasith, Tust
    Verdini, Daniel
    Do, Synho
    Liu, Bob
    Li, Xinhua
    Sala, Michiel
    Kim, Mi Sung
    Blankstein, Ron
    Prakash, Priyanka
    Sidhu, Manavjot S.
    Corsini, Erin
    Banerji, Dahlia
    Wu, David
    Abbara, Suhny
    Quynh Truong
    Brady, Thomas J.
    Hoffmann, Udo
    Kalra, Manudeep
    AMERICAN JOURNAL OF MEDICINE, 2012, 125 (08): : 764 - 772
  • [48] Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality
    Bouchra Habib Geryes
    Raphael Calmon
    Diala Khraiche
    Nathalie Boddaert
    Damien Bonnet
    Francesca Raimondi
    European Radiology, 2016, 26 : 2030 - 2038
  • [49] Research on 4D radiation dose calculation of human body
    Zhao R.
    Liu Z.
    Liu N.
    Zhang J.
    Liang R.
    Wang X.
    Dai Y.
    Linghu R.
    Liu L.
    He Jishu/Nuclear Techniques, 2023, 46 (01):
  • [50] Radiation dose reduction in hepatic multidetector computed tomography with a novel adaptive noise reduction filter
    Funama, Yoshinori
    Awai, Kazuo
    Miyazaki, Osamu
    Goto, Taiga
    Nakayama, Yoshiharu
    Shimamura, Masamitchi
    Hiraishi, Kumiko
    Hori, Shinichi
    Yamashita, Yasuyuki
    RADIATION MEDICINE, 2008, 26 (03): : 171 - 177