Radiation dose reduction in 4D computed tomography

被引:2
|
作者
Li, T [1 ]
Schreibmann, E [1 ]
Thomdyke, B [1 ]
Xing, L [1 ]
机构
[1] Stanford Univ, Med Ctr, Sch Med, Stanford, CA 94305 USA
关键词
D O I
10.1118/1.1998393
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: 4D CT is useful clinically for detailed abdominal and thoracic imaging over the course of the respiratory cycle. However, it usually delivers 10∼15 times more radiation dose to the patient as compared to the standard 3D CT, since multiple scans at each couch position are required to obtain the temporal information. In this work we propose a method to obtain high quality 4D CT with low tube current, hence reducing the radiation exposure of patients. Method and Materials: The improvement of the signal‐to‐noise ratio (SNR) of the CT image at a given phase was achieved by superposing the imaging information from other phases with the use of a deformable image registration model. To further reduce the statistical noise caused by low tube current, we developed a novel 4D penalized weighted least square (4D‐PWLS) method to smooth the data spatially and temporally. The method was validated by motion‐phantom and patient studies using a GE Discovery‐ST PET/CT scanner. A Varian RPM respiratory gating system was used to track the motion and to facilitate the phase binning of the 4D CT data. Results: We calculated the SNRs for both studies. The average SNR of 10 mA phantom images increased by more than three‐fold from 0.051 to 0.165 after the proposed 4D‐PWLS processing, without noticeable resolution loss. The patient images acquired at 90mA showed an increase from 2.204 to 4.558 for the end‐inspiration phase, and from 1.741 to 3.862 for the end‐expiration phase, respectively. By examining the subtraction images before and after processing, good edge preservation was also observed in the patient study. Conclusion: By appropriately utilizing the temporal information in 4D‐CT, the proposed method effectively suppresses the noise while preserving the resolution. The technique provides a useful way to reduce the patient dose during 4D CT and is thus valuable for 4D‐radiotherapy. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2094 / 2095
页数:2
相关论文
共 50 条
  • [21] Image Quality in Computed Tomography Coronary Angiography and Radiation Dose Reduction
    Golubickas, Domas
    Lukosevicius, Saulius
    Tamakauskas, Vytenis
    Dobrovolskiene, Laima
    Baseviciene, Ingrida
    Grib, Liviu
    Ragaisyte, Nijole
    Leonavicius, Rytis
    Medvedev, Viktor
    Veikutis, Vincentas
    INFORMATICA, 2021, 32 (04) : 741 - 757
  • [22] Evaluation of 4D computed tomography for planning boost radiation therapy in breast-conserving therapy
    McGibney, CA
    Abbas, A
    Chan, B
    Ubhi, R
    Mosseri, A
    Kane, G
    Lee, M
    Chhin, V
    Koch, A
    Alasti, H
    Jaffray, D
    Vallis, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S249 - S250
  • [23] Quantifying the image quality and dose reduction of respiratory triggered 4D cone-beam computed tomography with patient-measured breathing
    Cooper, Benjamin J.
    O'Brien, Ricky T.
    Kipritidis, John
    Shieh, Chun-Chien
    Keall, Paul J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (24): : 9493 - 9513
  • [24] Quantifying the Image Quality and Dose Reduction of Respiratory Triggered 4D Cone-Beam Computed Tomography with Patient-Measured Breathing
    Cooper, B.
    OBrien, R.
    Kipritidis, J.
    Keall, P.
    MEDICAL PHYSICS, 2014, 41 (06) : 199 - +
  • [25] Noise reduction and motion elimination in low-dose 4D myocardial computed tomography perfusion (CTP): preliminary clinical evaluation of the ASTRA4D algorithm
    Lukas, Steffen
    Feger, Sarah
    Rief, Matthias
    Zimmermann, Eike
    Dewey, Marc
    EUROPEAN RADIOLOGY, 2019, 29 (09) : 4572 - 4582
  • [26] Noise reduction and motion elimination in low-dose 4D myocardial computed tomography perfusion (CTP): preliminary clinical evaluation of the ASTRA4D algorithm
    Steffen Lukas
    Sarah Feger
    Matthias Rief
    Elke Zimmermann
    Marc Dewey
    European Radiology, 2019, 29 : 4572 - 4582
  • [27] Optimizing image quality and minimizing radiation dose in pediatric abdominal multiphase contrast-enhanced computed tomography: a study on CARE kV and CARE Dose 4D
    Tian, Xinyu
    Chang, Zhenjiang
    Dilixiati, Subinuer
    Haimiti, Yilisuyaer
    Wang, Shui
    Sun, Jihang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (02) : 1985 - 1993
  • [28] FETAL RADIATION DOSE IN COMPUTED TOMOGRAPHY
    Kelaranta, Anna
    Kaasalainen, Touko
    Seuri, Raija
    Toroi, Paula
    Kortesniemi, Mika
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 226 - 230
  • [29] Radiation dose in cardiovascular computed tomography
    Gingold, E.
    MEDICAL PHYSICS, 2007, 34 (06) : 2345 - 2345
  • [30] Radiation dose in computed tomography of the heart
    Morin, RL
    Gerber, TC
    McCollough, CH
    CIRCULATION, 2003, 107 (06) : 917 - 922