Radiation dose reduction in 4D computed tomography

被引:2
|
作者
Li, T [1 ]
Schreibmann, E [1 ]
Thomdyke, B [1 ]
Xing, L [1 ]
机构
[1] Stanford Univ, Med Ctr, Sch Med, Stanford, CA 94305 USA
关键词
D O I
10.1118/1.1998393
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: 4D CT is useful clinically for detailed abdominal and thoracic imaging over the course of the respiratory cycle. However, it usually delivers 10∼15 times more radiation dose to the patient as compared to the standard 3D CT, since multiple scans at each couch position are required to obtain the temporal information. In this work we propose a method to obtain high quality 4D CT with low tube current, hence reducing the radiation exposure of patients. Method and Materials: The improvement of the signal‐to‐noise ratio (SNR) of the CT image at a given phase was achieved by superposing the imaging information from other phases with the use of a deformable image registration model. To further reduce the statistical noise caused by low tube current, we developed a novel 4D penalized weighted least square (4D‐PWLS) method to smooth the data spatially and temporally. The method was validated by motion‐phantom and patient studies using a GE Discovery‐ST PET/CT scanner. A Varian RPM respiratory gating system was used to track the motion and to facilitate the phase binning of the 4D CT data. Results: We calculated the SNRs for both studies. The average SNR of 10 mA phantom images increased by more than three‐fold from 0.051 to 0.165 after the proposed 4D‐PWLS processing, without noticeable resolution loss. The patient images acquired at 90mA showed an increase from 2.204 to 4.558 for the end‐inspiration phase, and from 1.741 to 3.862 for the end‐expiration phase, respectively. By examining the subtraction images before and after processing, good edge preservation was also observed in the patient study. Conclusion: By appropriately utilizing the temporal information in 4D‐CT, the proposed method effectively suppresses the noise while preserving the resolution. The technique provides a useful way to reduce the patient dose during 4D CT and is thus valuable for 4D‐radiotherapy. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2094 / 2095
页数:2
相关论文
共 50 条
  • [31] PEDIATRIC DOSE REDUCTION IN COMPUTED TOMOGRAPHY
    Frush, Donald P.
    HEALTH PHYSICS, 2008, 95 (05): : 518 - 527
  • [32] Dose reduction in abdominal computed tomography
    Toepker, M.
    Ringl, H.
    RADIOLOGE, 2012, 52 (10): : 919 - +
  • [33] Dose reduction in multislice computed tomography
    Hundt, W
    Rust, F
    Stäbler, A
    Wolff, H
    Suess, C
    Reiser, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (01) : 140 - 147
  • [34] "Locked" Scapholunate Instability Diagnosed with 4D Computed Tomography Scan
    Bain, Gregory, I
    Krishna, Sathya Vamsi
    MacLean, Simon
    Carr, Renee
    Slavotinek, John
    JOURNAL OF WRIST SURGERY, 2019, 8 (04) : 321 - 326
  • [35] White Matter and Gray Matter Segmentation in 4D Computed Tomography
    Rashindra Manniesing
    Marcel T. H. Oei
    Luuk J. Oostveen
    Jaime Melendez
    Ewoud J. Smit
    Bram Platel
    Clara I. Sánchez
    Frederick J. A. Meijer
    Mathias Prokop
    Bram van Ginneken
    Scientific Reports, 7
  • [36] White Matter and Gray Matter Segmentation in 4D Computed Tomography
    Manniesing, Rashindra
    Oei, Marcel T. H.
    Oostveen, Luuk J.
    Melendez, Jaime
    Smit, Ewoud J.
    Platel, Bram
    Sanchez, Clara I.
    Meijer, Frederick J. A.
    Prokop, Mathias
    van Ginneken, Bram
    SCIENTIFIC REPORTS, 2017, 7
  • [37] Respiratory triggered 4D cone-beam computed tomography: A novel method to reduce imaging dose
    Cooper, Benjamin J.
    O'Brien, Ricky T.
    Balik, Salim
    Hugo, Geoffrey D.
    Keall, Paul J.
    MEDICAL PHYSICS, 2013, 40 (04)
  • [38] Interactive deformable registration visualization and analysis of 4D computed tomography
    Erem, Burak
    Sharp, Gregory C.
    Wu, Ziji
    Kaeli, David
    MEDICAL BIOMETRICS, PROCEEDINGS, 2007, 4901 : 232 - +
  • [39] Radiation Dose From Cardiac Computed Tomography Before and After Implementation of Radiation Dose-Reduction Techniques
    Raff, Gilbert L.
    Chinnaiyan, Kavitha M.
    Share, David A.
    Goraya, Tauqir Y.
    Kazerooni, Ella A.
    Moscucci, Mauro
    Gentry, Ralph E.
    Abidov, Aiden
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (22): : 2340 - 2348
  • [40] Dose Reduction in Kilovotage Cone-Beam Computed Tomography for Radiation Therapy
    Wang, J.
    Li, T.
    Liang, J.
    Xing, L.
    MEDICAL PHYSICS, 2008, 35 (06)