Continuous glucose monitoring using a microneedle array sensor coupled with a wireless signal transmitter

被引:77
|
作者
Kim, Kwang Bok [1 ]
Lee, Won-Chul [2 ]
Cho, Chul-Ho [1 ]
Park, Deog-Su [3 ]
Cho, Seong Je [1 ]
Shim, Yoon-Bo [2 ]
机构
[1] Samsung Elect, Samsung Res, Seoul R&D Campus,34,Seongchon Gil, Seoul 06765, South Korea
[2] Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
[3] Pusan Natl Univ, IBST, Busan 46241, South Korea
关键词
Glucose sensor; Wireless biosensor; Microneedle array; Carboxylated-poly(terthiophene); Point-of care; ELECTRON-TRANSFER; SYSTEMS;
D O I
10.1016/j.snb.2018.10.081
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A minimally invasive wireless biosensor was developed for glucose monitoring using human blood. The sensor probe was shaped in a microneedle array with a cyclic olefin copolymer. FAD-glucose oxidase (GOx) was covalently bound to a terthiophene carboxylic acid (TCA) monomer followed by electropolymerization on a gold-coated microneedle (AuMN) array using the potential cycling method (AuMN/pTCA-GOx). The formation of the sensing probe layer on the needle was confirmed by employing electrochemical and surface characterization experiments. To prevent the interfering species and the detaching of the probe material, the AuMN/pTCA-GOx surface was protected with Nafion. To enhance the repeatability and stability of the sensor, it was pretreated by applying the sequential negative and positive pulses immediately prior to each measurement. The sequential pulse allowed the sensor to have a high repeatability (Coefficient of variation = 1.1%, n = 10), and continuously long-term stability (Coefficient of variation = 5.56% for 72 h). The sensor has an excellent linear response at glucose concentrations between 0.05 and 20.0 mM (R-2 = 0.99) with a sensitivity of 0.22 mu A/mM(-1) cm(-2) (Coefficient of variation = 1.7%) and the detection limit of 19.4 ( +/- 0.62) mu A. The reliability of the proposed method was performed on finger through coupling of the sensor part to a reusable wireless transmitter that sends the measured values to a mobile phone via Bluetooth.
引用
收藏
页码:14 / 21
页数:8
相关论文
共 50 条
  • [31] A Perspective on microneedle sensor arrays for continuous monitoring of the body's chemistry
    Freeman, D. M. E.
    Cass, A. E. G.
    APPLIED PHYSICS LETTERS, 2022, 121 (07)
  • [32] Fabrication of Composite Microneedle Array Electrode for Temperature and Bio-Signal Monitoring
    Sun, Yiwei
    Ren, Lei
    Jiang, Lelun
    Tang, Yong
    Liu, Bin
    SENSORS, 2018, 18 (04)
  • [33] An integrated wearable microneedle array for the continuous monitoring of multiple biomarkers in interstitial fluid
    Tehrani, Farshad
    Teymourian, Hazhir
    Wuerstle, Brian
    Kavner, Jonathan
    Patel, Ravi
    Furmidge, Allison
    Aghavali, Reza
    Hosseini-Toudeshki, Hamed
    Brown, Christopher
    Zhang, Fangyu
    Mahato, Kuldeep
    Li, Zhengxing
    Barfidokht, Abbas
    Yin, Lu
    Warren, Paul
    Huang, Nickey
    Patel, Zina
    Mercier, Patrick P.
    Wang, Joseph
    NATURE BIOMEDICAL ENGINEERING, 2022, 6 (11) : 1214 - 1224
  • [34] Array signal processing for a wireless MEM sensor network
    Yao, K
    Hudson, RE
    Reed, CW
    Chen, D
    Tung, TL
    Lorenzelli, F
    1998 IEEE WORKSHOP ON SIGNAL PROCESSING SYSTEMS-SIPS 98: DESIGN AND IMPLEMENTATION, 1998, : 11 - 20
  • [35] An integrated wearable microneedle array for the continuous monitoring of multiple biomarkers in interstitial fluid
    Farshad Tehrani
    Hazhir Teymourian
    Brian Wuerstle
    Jonathan Kavner
    Ravi Patel
    Allison Furmidge
    Reza Aghavali
    Hamed Hosseini-Toudeshki
    Christopher Brown
    Fangyu Zhang
    Kuldeep Mahato
    Zhengxing Li
    Abbas Barfidokht
    Lu Yin
    Paul Warren
    Nickey Huang
    Zina Patel
    Patrick P. Mercier
    Joseph Wang
    Nature Biomedical Engineering, 2022, 6 : 1214 - 1224
  • [36] WIRELESS NDE SENSOR SYSTEM FOR CONTINUOUS MONITORING
    Dib, G.
    Mhamdi, L.
    Khan, T.
    Udpa, L.
    Lajnef, N.
    Hong, J. -W.
    Udpa, S.
    Ramuhalli, P.
    Balasubramaniam, K.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 30A AND 30B, 2011, 1335 : 1758 - 1765
  • [37] A long lifetime and highly sensitive wearable microneedle sensor for the continuous real-time monitoring of glucose in interstitial fluid
    Yin, Sijie
    Yu, Zhiqiang
    Song, Ningning
    Guo, Zhanjun
    Li, Wei
    Ma, Jinhang
    Wang, Xiaoyan
    Liu, Junyao
    Liang, Minmin
    BIOSENSORS & BIOELECTRONICS, 2024, 244
  • [38] An oxygen-insensitive and minimally invasive polymeric microneedle sensor for continuous and wide-range transdermal glucose monitoring
    Sharifuzzaman, Md
    Do Shin, Young
    Yoo, Junghyun
    Reza, Md Selim
    Kim, Yang-Rae
    Park, Jae Y.
    TALANTA, 2023, 263
  • [39] A MEMS viscometric sensor for continuous glucose monitoring
    Zhao, Yongjun
    Li, Siqi
    Davidson, Arthur
    Yang, Bozhi
    Wang, Qian
    Lin, Qiao
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (12) : 2528 - 2537
  • [40] SiC RF Sensor for Continuous Glucose Monitoring
    Fabiola Araujo Cespedes
    Gokhan Mumcu
    Stephen E. Saddow
    MRS Advances, 2016, 1 (55) : 3691 - 3696