Continuous glucose monitoring using a microneedle array sensor coupled with a wireless signal transmitter

被引:77
|
作者
Kim, Kwang Bok [1 ]
Lee, Won-Chul [2 ]
Cho, Chul-Ho [1 ]
Park, Deog-Su [3 ]
Cho, Seong Je [1 ]
Shim, Yoon-Bo [2 ]
机构
[1] Samsung Elect, Samsung Res, Seoul R&D Campus,34,Seongchon Gil, Seoul 06765, South Korea
[2] Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
[3] Pusan Natl Univ, IBST, Busan 46241, South Korea
关键词
Glucose sensor; Wireless biosensor; Microneedle array; Carboxylated-poly(terthiophene); Point-of care; ELECTRON-TRANSFER; SYSTEMS;
D O I
10.1016/j.snb.2018.10.081
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A minimally invasive wireless biosensor was developed for glucose monitoring using human blood. The sensor probe was shaped in a microneedle array with a cyclic olefin copolymer. FAD-glucose oxidase (GOx) was covalently bound to a terthiophene carboxylic acid (TCA) monomer followed by electropolymerization on a gold-coated microneedle (AuMN) array using the potential cycling method (AuMN/pTCA-GOx). The formation of the sensing probe layer on the needle was confirmed by employing electrochemical and surface characterization experiments. To prevent the interfering species and the detaching of the probe material, the AuMN/pTCA-GOx surface was protected with Nafion. To enhance the repeatability and stability of the sensor, it was pretreated by applying the sequential negative and positive pulses immediately prior to each measurement. The sequential pulse allowed the sensor to have a high repeatability (Coefficient of variation = 1.1%, n = 10), and continuously long-term stability (Coefficient of variation = 5.56% for 72 h). The sensor has an excellent linear response at glucose concentrations between 0.05 and 20.0 mM (R-2 = 0.99) with a sensitivity of 0.22 mu A/mM(-1) cm(-2) (Coefficient of variation = 1.7%) and the detection limit of 19.4 ( +/- 0.62) mu A. The reliability of the proposed method was performed on finger through coupling of the sensor part to a reusable wireless transmitter that sends the measured values to a mobile phone via Bluetooth.
引用
收藏
页码:14 / 21
页数:8
相关论文
共 50 条
  • [41] Fiberoptic hybrid sensor for continuous glucose monitoring
    Koehler, H.
    Pasic, A.
    Klimant, I.
    Schaupp, L.
    Pieber, T. R.
    [J]. DIABETOLOGIA, 2006, 49 : 584 - 585
  • [42] Injection Moulded Microneedle Sensor for Real-Time Wireless pH Monitoring
    Mirza, Khalid B.
    Zuliani, Claudio
    Hou, Benjamin
    Ng, Fu Siong
    Peters, Nicholas S.
    Toumazou, Christofer
    [J]. 2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 189 - 192
  • [43] A Wearable Microneedle Array Sensor Shows High Correlation between Dermal Glucose and Venous Blood Glucose
    Samant, Pradnya P.
    Christiansen, Mark P.
    Sattayasamitsathit, Sirilak
    Campbell, Alan
    Peyser, Thomas A.
    Windmiller, Joshua R.
    Tangney, Jared R.
    Lal, Rayhan
    Bhavaraju, Naresh C.
    [J]. DIABETES, 2020, 69
  • [44] Silk/polyols/GOD microneedle based electrochemical biosensor for continuous glucose monitoring
    Zhao, Liang
    Wen, Zhuangzhuang
    Jiang, Fujian
    Zheng, Zhaozhu
    Lu, Shenzhou
    [J]. RSC ADVANCES, 2020, 10 (11) : 6163 - 6171
  • [45] SKIN-ATTACHABLE AND IMPLANTABLE POLYMER MICRONEEDLE BIOSENSOR FOR CONTINUOUS GLUCOSE MONITORING
    Kim, Hyunsik
    Yoon, Hyosang
    Sharifuzzaman, Md
    Park, Jongcheol
    Kim, Daeheum
    Park, Jaeyeong
    [J]. 2020 33RD IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2020), 2020, : 404 - 407
  • [46] Modularized wireless dense sensor array for infrastructure monitoring
    Qi, GZ
    Chang, P
    Dong, W
    Qi, X
    Guo, X
    [J]. PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON EARTHQUAKE ENGINEERING: NEW FRONTIER AND RESEARCH TRANSFORMATION, 2004, : 920 - 925
  • [47] Deployment of a Wireless Ultrasonic Sensor Array for Psychological Monitoring
    Cheng, Roland
    Heinzelman, Wendi
    Sturge-Apple, Melissa
    Ignjatovic, Zeljko
    [J]. SENSOR APPLICATIONS, EXPERIMENTATION, AND LOGISTICS, 2010, 29 : 56 - 67
  • [48] Wearable Electrochemical Microneedle Sensor for Continuous Monitoring of Levodopa: Toward Parkinson Management
    Goud, K. Yugender
    Moonla, Chochanon
    Mishra, Rupesh K.
    Yu, Chunmei
    Narayan, Roger
    Litvan, Irene
    Wang, Joseph
    [J]. ACS SENSORS, 2019, 4 (08): : 2196 - 2204
  • [49] SEQUENTIAL WIRELESS SENSOR NETWORK DISCOVERY USING WIDE APERTURE ARRAY SIGNAL PROCESSING
    Willerton, M.
    Banavar, M.
    Zhang, X.
    Manikas, A.
    Tepedelenlioglu, C.
    Spanias, A.
    Thornton, T.
    Yeatman, E.
    Constantinides, A.
    [J]. 2012 PROCEEDINGS OF THE 20TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2012, : 2278 - 2282
  • [50] In vivo continuous glucose monitoring using a chip based near infrared sensor
    Ben Mohammadi, L.
    Sigloch, S.
    Frese, I.
    Welzel, K.
    Goeddel, M.
    Klotzbuecher, T.
    [J]. BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE IV, 2014, 9129