A long lifetime and highly sensitive wearable microneedle sensor for the continuous real-time monitoring of glucose in interstitial fluid

被引:19
|
作者
Yin, Sijie [1 ]
Yu, Zhiqiang [2 ]
Song, Ningning [3 ]
Guo, Zhanjun [3 ]
Li, Wei [3 ]
Ma, Jinhang [1 ]
Wang, Xiaoyan [3 ]
Liu, Junyao [4 ]
Liang, Minmin [3 ]
机构
[1] Beijing Inst Technol, Sch Automat, 5 South St, Beijing 100081, Peoples R China
[2] Beijing Inst Technol, Yangtze Delta Reg Acad, Jiaxing 314000, Peoples R China
[3] Beijing Inst Technol, Expt Ctr Adv Mat, Sch Mat Sci & Engn, 5 South St, Beijing 100081, Peoples R China
[4] Beijing Univ Technol, Fan Gongxiu Honors Coll, 100 Pingleyuan, Beijing 100124, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2024年 / 244卷
基金
中国国家自然科学基金;
关键词
Continuous glucose monitoring; Biosensor; Microneedle; Skin patch; BIOSENSOR;
D O I
10.1016/j.bios.2023.115822
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The short lifetime and low sensitivity of the current glucose electrochemical sensors are two major issues for implementing continuous real-time monitoring of glucose in vivo. Here we show that a unique microneedle-based glucose monitoring skin patch (termed here MGMSP) can continuously measure glucose in real time in live animals with micromolar sensitivity and over 14 days of service life. This MGMSP employs a glucose oxidase (GOD) and carbon nanotube (CNT) modified hollow syringe as electrochemical sensor for glucose monitoring, an integrated circuit for signal processing and transmission, and the real-time glucose levels are displayed on smartphone via Bluetooth. The designed microneedle device protects the stability of the sensing molecules immobilized within the inner surface of hollow syringe and simultaneously the interior space of hollow syringe substantially increases the amount of immobilized sensing molecules. This microneedle design thus extends the lifetime as well as improves the detection sensitivity. The final MGMSP enables the continuous real-time monitoring of glucose in the interstitial fluid of live rats. This innovative microneedle-based MGMSP could potentially provide the public with high-accuracy continual glucose monitoring.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Continuous Glucose Monitoring by Real Time Sensor in Interstitial Fluid
    Honsova, Sarka
    Navratil, Tomas
    XXXIII MODERNI ELEKTROCHEMICKE METODY, 2013, : 63 - 67
  • [2] A novel electrochemical microneedle sensor for highly sensitive real time monitoring of glucose
    Ming, Tao
    Lan, Tingting
    Yu, Mingxing
    Duan, Xu
    Cheng, Shuhan
    Wang, Hong
    Deng, Juan
    Kong, Deling
    Yang, Shuang
    Shen, Zhongyang
    MICROCHEMICAL JOURNAL, 2024, 207
  • [3] Wearable electrochemical microneedle sensing platform for real-time continuous interstitial fluid monitoring of apomorphine: Toward Parkinson management
    Goud, K. Yugender
    Mahato, Kuldeep
    Teymourian, Hazhir
    Longardner, Katherine
    Litvan, Irene
    Wang, Joseph
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 354
  • [4] Interstitial fluid glucose time-lag correction for real-time continuous glucose monitoring
    Keenan, D. Barry
    Mastrototaro, John J.
    Weinzimer, Stuart A.
    Steil, Garry M.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (01) : 81 - 89
  • [5] 3D-printed microneedle arrays for real-time interstitial fluid glucose monitoring
    Zhou, Qingdi
    Wang, Yangjun
    Pan, Mingqiang
    Wang, Chunju
    Chen, Liguo
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2025, 35 (03)
  • [6] Impedance-based polymer microneedle patch sensor for continuous interstitial fluid glucose monitoring
    Piao, Honglin
    Choi, Yong-Ho
    Kim, Jaehyun
    Park, Daerl
    Lee, Jia
    Khang, Dahl-Young
    Choi, Heon-Jin
    BIOSENSORS & BIOELECTRONICS, 2024, 247
  • [7] An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids
    Yang, Yong
    Sheng, Can
    Dong, Fang
    Liu, Sheng
    BIOSENSORS & BIOELECTRONICS, 2024, 256
  • [8] An integrated wearable microneedle array for the continuous monitoring of multiple biomarkers in interstitial fluid
    Tehrani, Farshad
    Teymourian, Hazhir
    Wuerstle, Brian
    Kavner, Jonathan
    Patel, Ravi
    Furmidge, Allison
    Aghavali, Reza
    Hosseini-Toudeshki, Hamed
    Brown, Christopher
    Zhang, Fangyu
    Mahato, Kuldeep
    Li, Zhengxing
    Barfidokht, Abbas
    Yin, Lu
    Warren, Paul
    Huang, Nickey
    Patel, Zina
    Mercier, Patrick P.
    Wang, Joseph
    NATURE BIOMEDICAL ENGINEERING, 2022, 6 (11) : 1214 - 1224
  • [9] An integrated wearable microneedle array for the continuous monitoring of multiple biomarkers in interstitial fluid
    Farshad Tehrani
    Hazhir Teymourian
    Brian Wuerstle
    Jonathan Kavner
    Ravi Patel
    Allison Furmidge
    Reza Aghavali
    Hamed Hosseini-Toudeshki
    Christopher Brown
    Fangyu Zhang
    Kuldeep Mahato
    Zhengxing Li
    Abbas Barfidokht
    Lu Yin
    Paul Warren
    Nickey Huang
    Zina Patel
    Patrick P. Mercier
    Joseph Wang
    Nature Biomedical Engineering, 2022, 6 : 1214 - 1224
  • [10] Transdermal Microneedle Array-based Sensor for Real Time Continuous Glucose Monitoring
    Hwa, Kuo-Yuan
    Subramani, Boopathi
    Chang, Po-Wen
    Chien, Mingnan
    Huang, Jung-Tang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (03): : 2455 - 2466