An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids

被引:4
|
作者
Yang, Yong [1 ]
Sheng, Can [1 ]
Dong, Fang [2 ]
Liu, Sheng [1 ,2 ,3 ,4 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Mech Sci & Engn, Wuhan 430074, Peoples R China
[2] Wuhan Univ, Inst Technol Sci, Wuhan 430072, Peoples R China
[3] Wuhan Univ, Sch Power & Mech Engn, Wuhan 430072, Peoples R China
[4] Wuhan Univ, Sch Microelect, Wuhan 430072, Peoples R China
来源
关键词
Interstitial fluid; Microneedles; Continuous glucose monitoring; Wearable sensors; INSERTION;
D O I
10.1016/j.bios.2024.116280
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Monitoring biomarkers in human interstitial fluids (ISF) using microneedle sensors has been extensively studied. However, most of the previous studies were limited to simple in vitro demonstrations and lacked system integration and analytical performance. Here we report a miniaturized, high-precision, fully integrated wearable electrochemical microneedle sensing device that works with a customized smartphone application to wirelessly and in real-time monitor glucose in human ISF. A microneedle array fabrication method is proposed which enables multiple individually addressable, regionally separated sensing electrodes on a single microneedle system. As a demonstration, a glucose sensor and a differential sensor are integrated in a single sensing patch. The differential sensing electrodes can eliminate common-mode interference signals, thus significantly improving the detection accuracy. The basic mechanism of microneedle penetration into the skin was analyzed using the finite element method (FEM). By optimizing the structure of the microneedle, the puncture efficiency was improved while the puncture force was reduced. The electrochemical properties, biocompatibility, and system stability of the microneedle sensing device were characterized before human application. The test results were closely correlated with the gold standard (blood). The platform can be used not only for glucose detection, but also for various ISF biomarkers, and it expands the potential of microneedle technology in wearable sensing.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] An integrated wearable microneedle array for the continuous monitoring of multiple biomarkers in interstitial fluid
    Tehrani, Farshad
    Teymourian, Hazhir
    Wuerstle, Brian
    Kavner, Jonathan
    Patel, Ravi
    Furmidge, Allison
    Aghavali, Reza
    Hosseini-Toudeshki, Hamed
    Brown, Christopher
    Zhang, Fangyu
    Mahato, Kuldeep
    Li, Zhengxing
    Barfidokht, Abbas
    Yin, Lu
    Warren, Paul
    Huang, Nickey
    Patel, Zina
    Mercier, Patrick P.
    Wang, Joseph
    [J]. NATURE BIOMEDICAL ENGINEERING, 2022, 6 (11) : 1214 - 1224
  • [2] An integrated wearable microneedle array for the continuous monitoring of multiple biomarkers in interstitial fluid
    Farshad Tehrani
    Hazhir Teymourian
    Brian Wuerstle
    Jonathan Kavner
    Ravi Patel
    Allison Furmidge
    Reza Aghavali
    Hamed Hosseini-Toudeshki
    Christopher Brown
    Fangyu Zhang
    Kuldeep Mahato
    Zhengxing Li
    Abbas Barfidokht
    Lu Yin
    Paul Warren
    Nickey Huang
    Zina Patel
    Patrick P. Mercier
    Joseph Wang
    [J]. Nature Biomedical Engineering, 2022, 6 : 1214 - 1224
  • [3] Continuous Glucose Monitoring System Based on Percutaneous Microneedle Array
    Chien, Ming-Nan
    Chen, Yu-Jen
    Bai, Chin-Han
    Huang, Jung-Tung
    [J]. MICROMACHINES, 2022, 13 (03)
  • [4] Use of Microneedle Array Devices for Continuous Glucose Monitoring: A Review
    El-Laboudi, Ahmed
    Oliver, Nick S.
    Cass, Anthony
    Johnston, Desmond
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (01) : 101 - 115
  • [5] Continuous Opioid Monitoring along with Nerve Agents on a Wearable Microneedle Sensor Array
    Mishra, Rupesh K.
    Goud, K. Yugender
    Li, Zhanhong
    Moonla, Chochanon
    Mohamed, Mona A.
    Tehrani, Farshad
    Teymourian, Hazhir
    Wang, Joseph
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2020, 142 (13) : 5991 - 5995
  • [6] A long lifetime and highly sensitive wearable microneedle sensor for the continuous real-time monitoring of glucose in interstitial fluid
    Yin, Sijie
    Yu, Zhiqiang
    Song, Ningning
    Guo, Zhanjun
    Li, Wei
    Ma, Jinhang
    Wang, Xiaoyan
    Liu, Junyao
    Liang, Minmin
    [J]. BIOSENSORS & BIOELECTRONICS, 2024, 244
  • [7] Fully integrated microneedle biosensor array for wearable multiplexed fitness biomarkers monitoring
    Zhong, Geng
    Liu, Qingzhou
    Wang, Qiyu
    Qiu, Haoji
    Li, Hanlin
    Xu, Tailin
    [J]. BIOSENSORS & BIOELECTRONICS, 2024, 265
  • [8] Wearable microneedle array-based sensor for transdermal monitoring of pH levels in interstitial fluid
    Dervisevic, Muamer
    Dervisevic, Esma
    Esser, Lars
    Easton, Christopher D.
    Cadarso, Victor J.
    Voelcker, Nicolas H.
    [J]. BIOSENSORS & BIOELECTRONICS, 2023, 222
  • [9] Fully integrated flexible biosensor for wearable continuous glucose monitoring
    Jin, Xiaofeng
    Li, Guanhua
    Xu, Tailin
    Su, Lei
    Yan, Dan
    Zhang, Xueji
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 196
  • [10] Continuous glucose monitoring using a microneedle array sensor coupled with a wireless signal transmitter
    Kim, Kwang Bok
    Lee, Won-Chul
    Cho, Chul-Ho
    Park, Deog-Su
    Cho, Seong Je
    Shim, Yoon-Bo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 281 : 14 - 21