Continuous glucose monitoring using a microneedle array sensor coupled with a wireless signal transmitter

被引:77
|
作者
Kim, Kwang Bok [1 ]
Lee, Won-Chul [2 ]
Cho, Chul-Ho [1 ]
Park, Deog-Su [3 ]
Cho, Seong Je [1 ]
Shim, Yoon-Bo [2 ]
机构
[1] Samsung Elect, Samsung Res, Seoul R&D Campus,34,Seongchon Gil, Seoul 06765, South Korea
[2] Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
[3] Pusan Natl Univ, IBST, Busan 46241, South Korea
关键词
Glucose sensor; Wireless biosensor; Microneedle array; Carboxylated-poly(terthiophene); Point-of care; ELECTRON-TRANSFER; SYSTEMS;
D O I
10.1016/j.snb.2018.10.081
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A minimally invasive wireless biosensor was developed for glucose monitoring using human blood. The sensor probe was shaped in a microneedle array with a cyclic olefin copolymer. FAD-glucose oxidase (GOx) was covalently bound to a terthiophene carboxylic acid (TCA) monomer followed by electropolymerization on a gold-coated microneedle (AuMN) array using the potential cycling method (AuMN/pTCA-GOx). The formation of the sensing probe layer on the needle was confirmed by employing electrochemical and surface characterization experiments. To prevent the interfering species and the detaching of the probe material, the AuMN/pTCA-GOx surface was protected with Nafion. To enhance the repeatability and stability of the sensor, it was pretreated by applying the sequential negative and positive pulses immediately prior to each measurement. The sequential pulse allowed the sensor to have a high repeatability (Coefficient of variation = 1.1%, n = 10), and continuously long-term stability (Coefficient of variation = 5.56% for 72 h). The sensor has an excellent linear response at glucose concentrations between 0.05 and 20.0 mM (R-2 = 0.99) with a sensitivity of 0.22 mu A/mM(-1) cm(-2) (Coefficient of variation = 1.7%) and the detection limit of 19.4 ( +/- 0.62) mu A. The reliability of the proposed method was performed on finger through coupling of the sensor part to a reusable wireless transmitter that sends the measured values to a mobile phone via Bluetooth.
引用
收藏
页码:14 / 21
页数:8
相关论文
共 50 条
  • [1] Transdermal Microneedle Array-based Sensor for Real Time Continuous Glucose Monitoring
    Hwa, Kuo-Yuan
    Subramani, Boopathi
    Chang, Po-Wen
    Chien, Mingnan
    Huang, Jung-Tang
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (03): : 2455 - 2466
  • [2] Continuous Glucose Monitoring System Based on Percutaneous Microneedle Array
    Chien, Ming-Nan
    Chen, Yu-Jen
    Bai, Chin-Han
    Huang, Jung-Tung
    [J]. MICROMACHINES, 2022, 13 (03)
  • [3] Use of Microneedle Array Devices for Continuous Glucose Monitoring: A Review
    El-Laboudi, Ahmed
    Oliver, Nick S.
    Cass, Anthony
    Johnston, Desmond
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (01) : 101 - 115
  • [4] A pilot study in humans of microneedle sensor arrays for continuous glucose monitoring
    Sharma, Sanjiv
    El-Laboudi, Ahmed
    Reddy, Monika
    Jugnee, Narvada
    Sivasubramaniyam, Sujan
    El Sharkawy, Mohamed
    Georgiou, Pantelis
    Johnston, Desmond
    Oliver, Nick
    Cass, Anthony E. G.
    [J]. ANALYTICAL METHODS, 2018, 10 (18) : 2088 - 2095
  • [5] An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids
    Yang, Yong
    Sheng, Can
    Dong, Fang
    Liu, Sheng
    [J]. BIOSENSORS & BIOELECTRONICS, 2024, 256
  • [6] Continuous Opioid Monitoring along with Nerve Agents on a Wearable Microneedle Sensor Array
    Mishra, Rupesh K.
    Goud, K. Yugender
    Li, Zhanhong
    Moonla, Chochanon
    Mohamed, Mona A.
    Tehrani, Farshad
    Teymourian, Hazhir
    Wang, Joseph
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2020, 142 (13) : 5991 - 5995
  • [7] Fluorescent-based biodegradable microneedle sensor array for tether-free continuous glucose monitoring with smartphone application
    Sang, Mingyu
    Cho, Myeongki
    Lim, Selin
    Min, In Sik
    Han, Yuna
    Lee, Chanwoo
    Shin, Jongwoon
    Yoon, Kukro
    Yeo, Woon-Hong
    Lee, Taeyoon
    Won, Sang Min
    Jung, Youngmee
    Heo, Yun Jung
    Yu, Ki Jun
    [J]. SCIENCE ADVANCES, 2023, 9 (22)
  • [8] Array Sensor: Monitoring Using Wireless Signals
    Hong, Jihoon
    Ohtsuki, Tomoaki
    [J]. 2013 INTERNATIONAL CONFERENCE ON ICT CONVERGENCE (ICTC 2013): FUTURE CREATIVE CONVERGENCE TECHNOLOGIES FOR NEW ICT ECOSYSTEMS, 2013, : 759 - 760
  • [9] Microneedle array sensor for monitoring glucose in single cell using glucose oxidase-bonded polyterthiophene coated on AuZn oxide layer
    Lee, Won-Chul
    Gurudatt, N. G.
    Park, Deog-Su
    Kim, Kwang Bok
    Choi, Cheol Soo
    Shim, Yoon-Bo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2020, 320
  • [10] Wireless Monitoring of Temperature and Humidity Using Sensor Array
    Noushad, Mohd
    Tauheed, Beenish
    Khan, Shakeb. A.
    Khan, Md. Ajmal
    [J]. 2015 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2015,