Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group

被引:53
|
作者
Chen, Min [1 ,2 ]
Zhang, Lina [1 ,3 ]
Xu, Jia [1 ,2 ]
Chen, Xinyi [1 ,2 ]
Gu, Yuxiang [1 ,2 ]
Ren, Yuping [4 ]
Wang, Kaijun [1 ,2 ]
机构
[1] Zhejiang Univ, Coll Med, Affiliated Hosp 2, Eye Ctr, 88 Jiefang Rd, Hangzhou 310009, Zhejiang, Peoples R China
[2] Zhejiang Prov Key Lab Ophthalmol, Hangzhou, Zhejiang, Peoples R China
[3] Lishui Peoples Hosp, Lishui, Zhejiang, Peoples R China
[4] Shaoxing Tradit Chinese Med Hosp, Shaoxing, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Intraocular pressure; iCare rebound tonometer; Non-contact tonometer; Goldmann applanation tonometer; Central corneal thickness; OCULAR RESPONSE ANALYZER; DYNAMIC CONTOUR; HEALTHY-SUBJECTS;
D O I
10.1186/s12886-019-1236-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Measurement of intraocular pressure (IOP) is essential for glaucoma patients. Many factors such as central corneal thickness (CCT) can affect the accuracy of IOP measurement. The purpose of this study was to evaluate the agreement of IOP measured by non-contact tonometer (NCT), iCare pro rebound tonometer (iCare), and Goldmann applanation tonometer (GAT) in different IOP group. Methods This was a Hospital-based cross-sectional study. Two hundred subjects were enrolled in this study. All subjects underwent IOP measurement using an NCT-iCare-GAT sequence. Bland-Altman, Pearson correlation and intraclass correlation analysis were performed using SPSS 17.0 software. The influence of CCT on each IOP measurement methods was evaluated by linear regression analysis. Results The mean difference (Delta) of NCT-GAT did not differ from (Delta) iCare-GAT in IOP < 10 and 10-21 mmHg group. However, (Delta) NCT-GAT was significantly higher than (Delta) iCare-GAT in IOP 22-30 and > 30 mmHg group (P < 0.05). Bland-Altman analysis showed significant agreement between the three devices (P < 0.01). IOP measurements of the three methods were significantly correlated with CCT (P < 0.01). Conclusions ICare pro shows a higher agreement with GAT over a wide range of IOP compared with NCT. The consistency between the three tonometers was similar in a low and normal IOP range. However, NCT shows a greater overestimate of IOP in moderate and higher IOP group. The variability of IOP measurement affected by CCT is NCT > iCare pro > GAT.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group
    Min Chen
    Lina Zhang
    Jia Xu
    Xinyi Chen
    Yuxiang Gu
    Yuping Ren
    Kaijun Wang
    BMC Ophthalmology, 19
  • [2] The influence of refractive errors on IOP measurement by rebound tonometry (ICare) and Goldmann applanation tonometry
    Avitabile, Teresio
    Longo, Antonio
    Rocca, Daniela
    Amato, Roberta
    Gagliano, Caterina
    Castaing, Marine
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (04) : 585 - 591
  • [3] The influence of refractive errors on IOP measurement by rebound tonometry (ICare) and Goldmann applanation tonometry
    Teresio Avitabile
    Antonio Longo
    Daniela Rocca
    Roberta Amato
    Caterina Gagliano
    Marine Castaing
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 585 - 591
  • [4] Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients
    Vincent, Stephen J.
    Vincent, Roslyn A.
    Shields, David
    Lee, Graham A.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (04): : E163 - E170
  • [5] Comparison of rebound tonometry and non-contact airpuff tonometry to Goldmann applanation tonometry
    Demirci, Goktug
    Erdur, Sevil Karaman
    Tanriverdi, Cafer
    Gulkitik, Gokhan
    Ozsutcu, Mustafa
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2019, 11
  • [6] The influence of corneal density and thickness on tonometry measurement with goldmann applanation, non-contact and iCare tonometry methods
    Ahmed Lubbad
    Irene Oluwatoba-Popoola
    Melanie Haar
    Carsten Framme
    Anna Bajor
    International Ophthalmology, 2022, 42 : 2167 - 2174
  • [7] The influence of corneal density and thickness on tonometry measurement with goldmann applanation, non-contact and iCare tonometry methods
    Lubbad, Ahmed
    Oluwatoba-Popoola, Irene
    Haar, Melanie
    Framme, Carsten
    Bajor, Anna
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (07) : 2167 - 2174
  • [8] IOP measurement in silicone oil tamponade eyes by Corvis ST tonometer, Goldmann applanation tonometry and non-contact tonometry
    Yang Zhang
    Lin Zheng
    Ailing Bian
    Qi Zhou
    International Ophthalmology, 2018, 38 : 697 - 703
  • [9] Intraocular pressure according to different types of tonometry (non-contact and Goldmann applanation) in patients with different degrees of bilateral tearing
    Seol, Bo Ram
    Kang, Tae Gu
    Gu, Bonhyeok
    PLOS ONE, 2019, 14 (09):
  • [10] Comparability of Icare Pro Rebound Tonometer with Goldmann Applanation and Noncontact Tonometer in a Wide Range of Intraocular Pressure and Central Corneal Thickness
    Tamcelik, Nevbahar
    Atalay, Eray
    Cicik, Erdogan
    Ozkok, Ahmet
    OPHTHALMIC RESEARCH, 2015, 54 (01) : 18 - 25