Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group

被引:53
|
作者
Chen, Min [1 ,2 ]
Zhang, Lina [1 ,3 ]
Xu, Jia [1 ,2 ]
Chen, Xinyi [1 ,2 ]
Gu, Yuxiang [1 ,2 ]
Ren, Yuping [4 ]
Wang, Kaijun [1 ,2 ]
机构
[1] Zhejiang Univ, Coll Med, Affiliated Hosp 2, Eye Ctr, 88 Jiefang Rd, Hangzhou 310009, Zhejiang, Peoples R China
[2] Zhejiang Prov Key Lab Ophthalmol, Hangzhou, Zhejiang, Peoples R China
[3] Lishui Peoples Hosp, Lishui, Zhejiang, Peoples R China
[4] Shaoxing Tradit Chinese Med Hosp, Shaoxing, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Intraocular pressure; iCare rebound tonometer; Non-contact tonometer; Goldmann applanation tonometer; Central corneal thickness; OCULAR RESPONSE ANALYZER; DYNAMIC CONTOUR; HEALTHY-SUBJECTS;
D O I
10.1186/s12886-019-1236-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Measurement of intraocular pressure (IOP) is essential for glaucoma patients. Many factors such as central corneal thickness (CCT) can affect the accuracy of IOP measurement. The purpose of this study was to evaluate the agreement of IOP measured by non-contact tonometer (NCT), iCare pro rebound tonometer (iCare), and Goldmann applanation tonometer (GAT) in different IOP group. Methods This was a Hospital-based cross-sectional study. Two hundred subjects were enrolled in this study. All subjects underwent IOP measurement using an NCT-iCare-GAT sequence. Bland-Altman, Pearson correlation and intraclass correlation analysis were performed using SPSS 17.0 software. The influence of CCT on each IOP measurement methods was evaluated by linear regression analysis. Results The mean difference (Delta) of NCT-GAT did not differ from (Delta) iCare-GAT in IOP < 10 and 10-21 mmHg group. However, (Delta) NCT-GAT was significantly higher than (Delta) iCare-GAT in IOP 22-30 and > 30 mmHg group (P < 0.05). Bland-Altman analysis showed significant agreement between the three devices (P < 0.01). IOP measurements of the three methods were significantly correlated with CCT (P < 0.01). Conclusions ICare pro shows a higher agreement with GAT over a wide range of IOP compared with NCT. The consistency between the three tonometers was similar in a low and normal IOP range. However, NCT shows a greater overestimate of IOP in moderate and higher IOP group. The variability of IOP measurement affected by CCT is NCT > iCare pro > GAT.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Influence of Corneal Thickness in Keratoconic Corneas on IOP Measurement with IOPen, iCare, Dynamic Contour Tonometry and Goldmann Applanation Tonometry
    Klamann, M. K. J.
    Maier, A. -K. B.
    Gonnermann, J.
    Ruokonen, P.
    Bertelmann, E.
    Torun, N.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2013, 230 (07) : 697 - 700
  • [32] Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous subjects
    Bang, Seung Pil
    Lee, Chong Eun
    Kim, Yu Cheol
    BMC OPHTHALMOLOGY, 2017, 17
  • [33] Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous subjects
    Seung Pil Bang
    Chong Eun Lee
    Yu Cheol Kim
    BMC Ophthalmology, 17
  • [34] Comparison of Intraocular Pressure Measurements Obtained by Rebound, Noncontact, and Goldmann Applanation Tonometry in Children
    Vodencarevic, Amra Nadarevic
    Jusufovic, Vahid
    Terzic, Svjetlana
    Halilbasic, Meliha
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 163 : 192 - 192
  • [35] Comparison of Intraocular Pressure Measurements Obtained by Rebound, Noncontact, and Goldmann Applanation Tonometry in Children
    Feng, Chi Shian
    Jin, Ki Won
    Yi, Kayoung
    Choi, Dong Gyu
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (05) : 937 - 943
  • [36] Difference in intraocular pressure measurements between non-contact tonometry and Goldmann applanation tonometry and the role of central corneal thickness in affecting glaucoma referrals
    Khalid Kamel
    Edward Dervan
    Kevin Falzon
    Colm O’Brien
    Irish Journal of Medical Science (1971 -), 2019, 188 : 321 - 325
  • [37] Meta-analysis of the concordance of Icare® PRO-based rebound and Goldmann applanation tonometry in glaucoma patients
    Roedter, Tara Helena
    Knippschild, Stephanie
    Baulig, Christine
    Krummenauer, Frank
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (02) : 245 - 252
  • [38] Difference in intraocular pressure measurements between non-contact tonometry and Goldmann applanation tonometry and the role of central corneal thickness in affecting glaucoma referrals
    Kamel, Khalid
    Dervan, Edward
    Falzon, Kevin
    O'Brien, Colm
    IRISH JOURNAL OF MEDICAL SCIENCE, 2019, 188 (01) : 321 - 325
  • [39] Comparison of Goldmann Applanation Tonometry and Dynamic Contour Tonometry in the Measurement of Intraocular Pressure in Eyes with Different Corneal Thicknesses
    Roszkowska, A. M.
    De Grazia, L.
    Cirone, M.
    Ferreri, G.
    OPHTHALMOLOGICA, 2009, 223 (04) : 244 - 249
  • [40] Comparison of Intraocular Pressure Measurements Using Three Different Methods (Goldmann Applanation Tonometry (GAT), Corvis ST, and iCare) Following Penetrating Keratoplasty
    Tziola, Tatiana
    Tzamalis, Argyrios
    Koronis, Spyridon
    Garitsis, Panagiotis
    Tsinopoulos, Ioannis
    Ziakas, Nikolaos
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (23)