Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group

被引:53
|
作者
Chen, Min [1 ,2 ]
Zhang, Lina [1 ,3 ]
Xu, Jia [1 ,2 ]
Chen, Xinyi [1 ,2 ]
Gu, Yuxiang [1 ,2 ]
Ren, Yuping [4 ]
Wang, Kaijun [1 ,2 ]
机构
[1] Zhejiang Univ, Coll Med, Affiliated Hosp 2, Eye Ctr, 88 Jiefang Rd, Hangzhou 310009, Zhejiang, Peoples R China
[2] Zhejiang Prov Key Lab Ophthalmol, Hangzhou, Zhejiang, Peoples R China
[3] Lishui Peoples Hosp, Lishui, Zhejiang, Peoples R China
[4] Shaoxing Tradit Chinese Med Hosp, Shaoxing, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Intraocular pressure; iCare rebound tonometer; Non-contact tonometer; Goldmann applanation tonometer; Central corneal thickness; OCULAR RESPONSE ANALYZER; DYNAMIC CONTOUR; HEALTHY-SUBJECTS;
D O I
10.1186/s12886-019-1236-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Measurement of intraocular pressure (IOP) is essential for glaucoma patients. Many factors such as central corneal thickness (CCT) can affect the accuracy of IOP measurement. The purpose of this study was to evaluate the agreement of IOP measured by non-contact tonometer (NCT), iCare pro rebound tonometer (iCare), and Goldmann applanation tonometer (GAT) in different IOP group. Methods This was a Hospital-based cross-sectional study. Two hundred subjects were enrolled in this study. All subjects underwent IOP measurement using an NCT-iCare-GAT sequence. Bland-Altman, Pearson correlation and intraclass correlation analysis were performed using SPSS 17.0 software. The influence of CCT on each IOP measurement methods was evaluated by linear regression analysis. Results The mean difference (Delta) of NCT-GAT did not differ from (Delta) iCare-GAT in IOP < 10 and 10-21 mmHg group. However, (Delta) NCT-GAT was significantly higher than (Delta) iCare-GAT in IOP 22-30 and > 30 mmHg group (P < 0.05). Bland-Altman analysis showed significant agreement between the three devices (P < 0.01). IOP measurements of the three methods were significantly correlated with CCT (P < 0.01). Conclusions ICare pro shows a higher agreement with GAT over a wide range of IOP compared with NCT. The consistency between the three tonometers was similar in a low and normal IOP range. However, NCT shows a greater overestimate of IOP in moderate and higher IOP group. The variability of IOP measurement affected by CCT is NCT > iCare pro > GAT.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Evaluation of differences in Intraocular Pressure (IOP) measurement between Tonoref III and Goldmann Applanation Tonometry (GAT)
    Lazari, Katerina C.
    Karpathaki, Margarita N.
    Linardakis, Manolis
    Christodoulakis, Emmanouil V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [22] Comparison of intraocular pressure measurement by Dynamic Contour Tonometry and Goldmann applanation tonometry
    DeBry, PW
    Krishna, R
    Willoughby, TL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U372 - U372
  • [23] Intraocular pressure and corneal thickness - A comparison between non-contact tonometry and applanation tonometry
    Domke, N.
    Hager, A.
    Wiegand, W.
    OPHTHALMOLOGE, 2006, 103 (07): : 583 - 587
  • [24] Comparison of IOP-measurements obtained by the non-contact tonometer AT555 and Goldmann applanation tonometry
    Mueller-Holz, M
    Schmidt, E
    Boehm, AG
    Pillunat, LE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [25] Intraocular pressure measurement - Comparison of dynamic contour tonometry and Goldmann applanation tonometry
    Schneider, E
    Grehn, F
    JOURNAL OF GLAUCOMA, 2006, 15 (01) : 2 - 6
  • [26] Clinical differences in rebound tonometry and Goldmann applanation tonometry measurements of intraocular pressure in adult patients
    Chiu, Zelia
    Collins, Camille
    van der Straaten, David
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 50 (08): : 923 - 924
  • [27] Comparative evaluation of TonoPen AVIA, Goldmann applanation tonometry and non-contact tonometry
    Bhartiya S.
    Bali S.J.
    Sharma R.
    Chaturvedi N.
    Dada T.
    International Ophthalmology, 2011, 31 (4) : 297 - 302
  • [28] Effect of central corneal thickness on intraocular pressure and comparison of Topcon CT-80 non-contact tonometry with Goldmann applanation tonometry
    Mansoori, Tarannum
    Balakrishna, Nagalla
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2018, 101 (02) : 206 - 212
  • [29] The Association of Central Corneal Thickness and Intraocular Pressure Measures by Non-Contact Tonometry and Goldmann Applanation Tonometry among Glaucoma Patients.
    Kyei, Samuel
    Assiamah, Frank
    Kwarteng, Michael Agyemang
    Gboglu, Cynthia Pakyennu
    ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2020, 30 (06) : 999 - 1004
  • [30] Comparison of intraocular pressure using Goldmann applanation tonometry versus non-contact tonometry in eyes with high-viscosity silicone oil
    Pagoulatos, Dionysios D.
    Kapsala, Zoi G.
    Makri, Olga E.
    Georgalas, Ilias G.
    Georgakopoulos, Constantinos D.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (03) : 494 - 499