Intraocular pressure according to different types of tonometry (non-contact and Goldmann applanation) in patients with different degrees of bilateral tearing

被引:3
|
作者
Seol, Bo Ram [1 ]
Kang, Tae Gu [1 ]
Gu, Bonhyeok [1 ]
机构
[1] Vet Hlth Serv VHS Med Ctr, Dept Ophthalmol, Seoul, South Korea
来源
PLOS ONE | 2019年 / 14卷 / 09期
关键词
D O I
10.1371/journal.pone.0222652
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To investigate intraocular pressure (IOP) readings by non-contact tonometry (NCT) and Goldmann applanation tonometry (GAT) for patients with different degrees of bilateral tearing. Methods In this study, we reviewed the medical charts of patients complaining of different degrees of bilateral tearing. The tear meniscus height (TMH) and lOP with NCT and GAT were measured. In each patient, a comparison of IOP readings between the eye with lower TMH and the contralateral eye with higher TMH was evaluated. The TMH was graded as follows: grade 1 (low): TMH < 0.2 mm; grade 2 (moderate): 0.2 mm <= TMH < 0.6 mm; grade 3 (high): TMH >= 0.6 mm. Subsequently, a comparison of 10P readings among eyes with low, moderate, and high TMH was also performed. Results A total of 120 eyes of 60 patients were enrolled. When comparing the two eyes of a patient, the eye with higher TMH showed higher NCT readings and larger difference in IOP readings between the two tonometries than the eye with lower TMH (P < 0.001 and P < 0.001, respectively). When TMH was classified into grades according to the degree, the high TMH eyes showed higher NCT readings than did the low and moderate TMH eyes (P < 0.001 and P = 0.001, respectively). In addition, the high TMH eyes showed a larger difference in IOP readings between the two tonometries than did the low and moderate TMH eyes (P < 0.001 and P < 0.001, respectively). Conclusion Eyes with higher TMH showed higher NCT readings and a larger difference in IOP between the two tonometries (NCT and GAT) than those with lower TMH. In patients with tearing, the NCT value may be inaccurate, so it is necessary to measure the GAT.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group
    Min Chen
    Lina Zhang
    Jia Xu
    Xinyi Chen
    Yuxiang Gu
    Yuping Ren
    Kaijun Wang
    BMC Ophthalmology, 19
  • [2] Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group
    Chen, Min
    Zhang, Lina
    Xu, Jia
    Chen, Xinyi
    Gu, Yuxiang
    Ren, Yuping
    Wang, Kaijun
    BMC OPHTHALMOLOGY, 2019, 19 (01)
  • [3] Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients
    Vincent, Stephen J.
    Vincent, Roslyn A.
    Shields, David
    Lee, Graham A.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (04): : E163 - E170
  • [4] The Association of Central Corneal Thickness and Intraocular Pressure Measures by Non-Contact Tonometry and Goldmann Applanation Tonometry among Glaucoma Patients.
    Kyei, Samuel
    Assiamah, Frank
    Kwarteng, Michael Agyemang
    Gboglu, Cynthia Pakyennu
    ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2020, 30 (06) : 999 - 1004
  • [5] Comparison of rebound tonometry and non-contact airpuff tonometry to Goldmann applanation tonometry
    Demirci, Goktug
    Erdur, Sevil Karaman
    Tanriverdi, Cafer
    Gulkitik, Gokhan
    Ozsutcu, Mustafa
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2019, 11
  • [6] NON-CONTACT TONOMETRY (KEELER PULSAIR) VS GOLDMANN APPLANATION TONOMETRY
    CLIMENHAGA, HW
    PLUCINSKA, H
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1988, 23 (02): : 86 - 86
  • [7] Intraocular pressure and corneal thickness - A comparison between non-contact tonometry and applanation tonometry
    Domke, N.
    Hager, A.
    Wiegand, W.
    OPHTHALMOLOGE, 2006, 103 (07): : 583 - 587
  • [8] Comparative evaluation of TonoPen AVIA, Goldmann applanation tonometry and non-contact tonometry
    Bhartiya S.
    Bali S.J.
    Sharma R.
    Chaturvedi N.
    Dada T.
    International Ophthalmology, 2011, 31 (4) : 297 - 302
  • [9] Effect of central corneal thickness on intraocular pressure and comparison of Topcon CT-80 non-contact tonometry with Goldmann applanation tonometry
    Mansoori, Tarannum
    Balakrishna, Nagalla
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2018, 101 (02) : 206 - 212
  • [10] Comparison of intraocular pressure using Goldmann applanation tonometry versus non-contact tonometry in eyes with high-viscosity silicone oil
    Pagoulatos, Dionysios D.
    Kapsala, Zoi G.
    Makri, Olga E.
    Georgalas, Ilias G.
    Georgakopoulos, Constantinos D.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (03) : 494 - 499