Intraocular pressure according to different types of tonometry (non-contact and Goldmann applanation) in patients with different degrees of bilateral tearing

被引:3
|
作者
Seol, Bo Ram [1 ]
Kang, Tae Gu [1 ]
Gu, Bonhyeok [1 ]
机构
[1] Vet Hlth Serv VHS Med Ctr, Dept Ophthalmol, Seoul, South Korea
来源
PLOS ONE | 2019年 / 14卷 / 09期
关键词
D O I
10.1371/journal.pone.0222652
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To investigate intraocular pressure (IOP) readings by non-contact tonometry (NCT) and Goldmann applanation tonometry (GAT) for patients with different degrees of bilateral tearing. Methods In this study, we reviewed the medical charts of patients complaining of different degrees of bilateral tearing. The tear meniscus height (TMH) and lOP with NCT and GAT were measured. In each patient, a comparison of IOP readings between the eye with lower TMH and the contralateral eye with higher TMH was evaluated. The TMH was graded as follows: grade 1 (low): TMH < 0.2 mm; grade 2 (moderate): 0.2 mm <= TMH < 0.6 mm; grade 3 (high): TMH >= 0.6 mm. Subsequently, a comparison of 10P readings among eyes with low, moderate, and high TMH was also performed. Results A total of 120 eyes of 60 patients were enrolled. When comparing the two eyes of a patient, the eye with higher TMH showed higher NCT readings and larger difference in IOP readings between the two tonometries than the eye with lower TMH (P < 0.001 and P < 0.001, respectively). When TMH was classified into grades according to the degree, the high TMH eyes showed higher NCT readings than did the low and moderate TMH eyes (P < 0.001 and P = 0.001, respectively). In addition, the high TMH eyes showed a larger difference in IOP readings between the two tonometries than did the low and moderate TMH eyes (P < 0.001 and P < 0.001, respectively). Conclusion Eyes with higher TMH showed higher NCT readings and a larger difference in IOP between the two tonometries (NCT and GAT) than those with lower TMH. In patients with tearing, the NCT value may be inaccurate, so it is necessary to measure the GAT.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Clinical differences in rebound tonometry and Goldmann applanation tonometry measurements of intraocular pressure in adult patients
    Chiu, Zelia
    Collins, Camille
    van der Straaten, David
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 50 (08): : 923 - 924
  • [22] The influence of corneal density and thickness on tonometry measurement with goldmann applanation, non-contact and iCare tonometry methods
    Lubbad, Ahmed
    Oluwatoba-Popoola, Irene
    Haar, Melanie
    Framme, Carsten
    Bajor, Anna
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (07) : 2167 - 2174
  • [23] Intraocular pressure difference in goldmann applanation tonometry versus Perkins hand-held applanation tonometry in overweight patients
    dos Santos, MG
    Makk, S
    Berghold, A
    Eckhardt, M
    Haas, A
    OPHTHALMOLOGY, 1998, 105 (12) : 2260 - 2263
  • [24] Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas
    Iglesias, Maria
    Casaroli-Marano, Ricardo P.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 2951 - 2952
  • [25] Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas
    De Bernardo, Maddalena
    Cembalo, Giovanni
    Rosa, Nicola
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 2783 - 2788
  • [26] COMPARISON OF INTRAOCULAR PRESSURE MEASURED WITH GOLDMANN APPLANATION TONOMETER AND NON-CONTACT AIR-PUFF TONOMETER
    Mahsud, Hidayatullah
    Saleem, Muhammad Wali
    Muhammad, Rafiq
    Saleem, Muhammad
    Ayaz, Mirqad
    GOMAL JOURNAL OF MEDICAL SCIENCES, 2016, 14 (02): : 63 - 66
  • [27] Comparison of the corrected intraocular pressure by tonopachy with that of Goldmann applanation tonometry in normal and glaucomatous patients
    Velis, Girish
    Kavitha, Srinivasan
    Zebardast, Nazlee
    Sengupta, Sabyasachi
    Venkatesh, Rengaraj
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (04) : 620 - 626
  • [28] IOP Measured by Dynamic Contour Tonometry Correlates With IOP Measured by Goldmann Applanation Tonometry and Non-contact Tonometry in Japanese Individuals
    Ito, Ken
    Tawara, Akihiko
    Kubota, Toshiaki
    Harada, Yukinori
    JOURNAL OF GLAUCOMA, 2012, 21 (01) : 35 - 40
  • [29] COMPARATIVE TONOMETRY WITH NON-CONTACT TONOMETER (NCT), PNEUMATONOGRAPH (PTG), AND GOLDMANN APPLANATION TONOMETER (GAT)
    SHIONO, T
    HARA, S
    KIMURA, R
    FOLIA OPHTHALMOLOGICA JAPONICA, 1978, 29 (10): : 1552 - 1555
  • [30] The influence of fluorescein and Goldmann's Applanation Tonometry on the Ultra-high Speed Dynamic Scheimpflug Non-contact Tonometry
    Macedo, Marcelo
    Hatanaka, Marcelo
    Susanna, Remo
    Ambrosio, Renato
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)