Full-field digital mammography: Dose-dependent detectability of simulated breast lesions

被引:27
|
作者
Obenauer, S [1 ]
Hermann, KP [1 ]
Schorn, C [1 ]
Fischer, U [1 ]
Grabbe, E [1 ]
机构
[1] Univ Gottingen Klinikum, Rontgendiagnost Abt 1, D-37075 Gottingen, Germany
关键词
full-field digital mammography; flat detector; dose reduction; contrast-detail detectability; microcalcifications;
D O I
10.1055/s-2000-9222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The study compares contrast-detail and microcalcification detectability of a full-field digital mammography (FFDM) to a state-of-the-art conventional screen-film mammography (SFM) by using different doses in the digital system. Materials and Methods: The investigations were performed with an FFDM (Senographe 2000 D, GEMS) and an SFM system (Senographe DMR, GEMS) using a contrast-detail mammography phantom (CDMAM) and an anthropomorphic breast phantom with superimposed microcalcifications. The digital detector was exposed with standard dose of SFM and with a dose reduction of up to 75%. Contrast-detail curves and correct observation ratio (COR) were performed for the CDMAM phantom. ROC analysis with a confidence level ranging from 1 to 5 was done with the results of the anthropomorphic phantom. Results: Digital mammography with the same dose revealed at least an equivalent or even higher detectability rate than conventional mammography, COR could be increased at about 10-25%. The ROC analysis yielded better results for the FFDM system. The same lesion detectability in digital mammography as in the conventional method was reached at a dose reduction of about 25%, concerning spot views even at higher reduction. Dose reduction in the anthropomorphic phantom resulted in a linear loss of detectability. The same detectability as in conventional mammography was reached, however, by a dose reduction of about 50%. Conclusion: The results suggest that FFDM is at least equivalent to or - as far as spot views are concerned - superior to conventional SFM concerning the detectability of simulated lesions. Thus, a potential of dose reduction is suggested.
引用
收藏
页码:1052 / 1056
页数:5
相关论文
共 50 条
  • [1] Full-field digital mammography: Dose-dependant detectability of simulated breast lesions
    Obenauer, S
    Hermann, K
    Grabbe, EH
    [J]. RADIOLOGY, 2001, 221 : 189 - 189
  • [2] Full-field digital mammography: A phantom study for the detectability of simulated microcalcifications.
    Obenauer, S
    Hermann, KP
    Schorn, C
    Funke, M
    Fischer, U
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (07): : 646 - 650
  • [3] Full-field digital mammography: An anthropomorphic phantom study for the detectability of simulated microcalcifications
    Obenauer, S
    Schorn, C
    Hermann, K
    Funke, M
    Fischer, U
    Grabbe, EH
    [J]. RADIOLOGY, 2000, 217 : 200 - 200
  • [4] Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions
    S. Obenauer
    S. Luftner-Nagel
    D. von Heyden
    U. Munzel
    F. Baum
    E. Grabbe
    [J]. European Radiology, 2002, 12 : 1697 - 1702
  • [5] Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions
    Obenauer, S
    Luftner-Nagel, S
    von Heyden, D
    Munzel, U
    Baum, F
    Grabbe, E
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (07) : 1697 - 1702
  • [6] Dose reduction in full-field digital mammography: an anthropomorphic breast phantom study
    Obenauer, S
    Hermann, KP
    Grabbe, E
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (907): : 478 - 482
  • [7] Erratum: Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions
    S. Obenauer
    S. Luftner-Nagel
    D. von Heyden
    U. Munzel
    F. Baum
    E. Grabbe
    [J]. European Radiology, 2002, 12 : 2388 - 2388
  • [8] Performance of full-field digital mammography versus digital breast
    Wang, Mengru
    Zhuang, Shan
    Sheng, Liuli
    Zhao, Yu Nian
    Shen, Wenrong
    [J]. PRECISION MEDICAL SCIENCES, 2022, 11 (02): : 56 - 61
  • [9] Addition of Digital Breast Tomosynthesis to Full-Field Digital Mammography in the Diagnostic Selling: Additional Value and Cancer Detectability
    Seo, Mirinae
    Chang, Jung Min
    kim, Sun Ah
    Kim, Won Hwa
    Lim, Ji He
    Lee, Su Hyun
    Bae, Min Sun
    Koo, Hye Ryoung
    Choi, Nariya
    Moon, Woo Kyung
    [J]. JOURNAL OF BREAST CANCER, 2016, 19 (04) : 438 - 446
  • [10] Full-field digital mammography
    Bick, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 957 - 964