Full-field digital mammography: A phantom study for the detectability of simulated microcalcifications.

被引:0
|
作者
Obenauer, S [1 ]
Hermann, KP [1 ]
Schorn, C [1 ]
Funke, M [1 ]
Fischer, U [1 ]
Grabbe, E [1 ]
机构
[1] Klinikum Georg August Univ Gottingen, Abt Rontgendiagnost 1, D-37075 Gottingen, Germany
关键词
full-field digital mammography; flat detector; microcalcifications;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The study compares direct full-field digital mammography (FFDM) to the state-of-the-art conventional screen-film mammography (SFM) concerning the detectability of simulated microcalcifications. Materials and Methods: The investigations were performed with a FFDM system (Senographe 2000D, GEMS) and a SFM system (Senographe DMR, GEMS, Fuji UM MA film with Fuji UM MAMMO FINE screen). An anthropomorphic breast phantom with superimposed microcalcifications (50-200 mu m) was used to evaluate the detectability of microcalcifications with a confidence level ranging from 1 to 5. Contact mammograms and magnification spot views (m = 1.8) of the FFDM and SFM systems were compared. A receiver operating characteristic (ROC) analysis was performed by three well-experienced readers. Results: The ROC analysis revealed a higher performance of the digital images compared to the conventional screen-film mammograms. The area under the ROC-curve (AZ) in the digital contact mammograms was 0.68 versus 0.63 in the conventional technique. The results were not significantly different. In digital spot views, A(Z) was 0.79 versus 0.70 in the conventional spot views. Conclusions: The results suggest that FFDM is at least equivalent or - as far as spot views are concerned - may be superior to conventional SFM in the detection of microcalcifications.
引用
收藏
页码:646 / 650
页数:9
相关论文
共 50 条
  • [1] Full-field digital mammography: An anthropomorphic phantom study for the detectability of simulated microcalcifications
    Obenauer, S
    Schorn, C
    Hermann, K
    Funke, M
    Fischer, U
    Grabbe, EH
    [J]. RADIOLOGY, 2000, 217 : 200 - 200
  • [2] Full-field digital mammography: Dose-dependant detectability of simulated breast lesions
    Obenauer, S
    Hermann, K
    Grabbe, EH
    [J]. RADIOLOGY, 2001, 221 : 189 - 189
  • [3] Full-field digital mammography: Dose-dependent detectability of simulated breast lesions
    Obenauer, S
    Hermann, KP
    Schorn, C
    Fischer, U
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 1052 - 1056
  • [4] Enhancement of microcalcifications in full-field digital mammography by energy subtraction
    Diekmann, F
    Diekmann, S
    Bick, U
    Hamm, B
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 577 - 580
  • [5] Comparison of the microcalcifications between full-field digital mammography and screen film mammography
    Tohno, E
    Kujiraoka, Y
    Watanabe, Y
    Itai, Y
    [J]. RADIOLOGY, 2001, 221 : 189 - 189
  • [6] Digital luminescence mammography (CR) versus full-field digital mammography (DR): A phantom study
    Schulz-Wendtland, RW
    Aichinger, UG
    Lell, MM
    Kuchar, I
    Tartsch, M
    Bautz, WA
    [J]. RADIOLOGY, 2002, 225 : 416 - 417
  • [7] Full-field digital mammography in comparison to screen-film mammography - A phantom study
    Obenauer, S
    Schorn, C
    Funke, M
    Fischer, U
    Grabbe, E
    Hermann, KP
    [J]. IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 499 - 503
  • [8] Magnification mammography: a comparison of full-field digital mammography and screen-film mammography for the detection of simulated small masses and microcalcifications
    K.-P. Hermann
    S. Obenauer
    M. Funke
    E. Grabbe
    [J]. European Radiology, 2002, 12 : 2188 - 2191
  • [9] Magnification mammography: a comparison of full-field digital mammography and screen-film mammography for the detection of simulated small masses and microcalcifications
    Hermann, KP
    Obenauer, S
    Funke, M
    Grabbe, EH
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (09) : 2188 - 2191
  • [10] Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography
    Fischer, U
    Baum, F
    Obenauer, S
    Luftner-Nagel, S
    von Heyden, D
    Vosshenrich, R
    Grabbe, E
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (11) : 2679 - 2683