Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography

被引:116
|
作者
Fischer, U [1 ]
Baum, F [1 ]
Obenauer, S [1 ]
Luftner-Nagel, S [1 ]
von Heyden, D [1 ]
Vosshenrich, R [1 ]
Grabbe, E [1 ]
机构
[1] Univ Gottingen, Dept Radiol, D-37075 Gottingen, Germany
关键词
microcalcification; full-field digital mammography; diagnostic accuracy;
D O I
10.1007/s00330-002-1354-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The goal of this prospective study was to compare a full-field digital mammography system (FFDM) to a conventional screen-film mammography system (SFM) for the detection and characterization of microcalcifications. Fifty-five patients with 57 isolated microcalcification clusters were examined using a FFDM system (Senographe 2000D, GE Medical Systems, Milwaukee, Wis.) and a SFM system (Senographe DMR, GE Medical Systems, Milwaukee, Wis.). A conventional screen-film mammogram and a digital contact mammogram were obtained of each cluster. The image quality and the number of calcification particles were evaluated, and a characterization (BI-RADS 1-5) of microcalcifications was given by four experienced readers. Histopathology revealed 16 benign lesions (sclerosing adenosis, dysplasia, hamartoma, radial scar) in 15 patients and 21 malignant tumors (in situ carcinoma, invasive carcinoma) in 20 patients. Twenty patients had benign changes verified by long-term follow-up. Image quality of FFDM was assessed as superior to SFM in more than 50% of the cases. The FFDM showed more calcifications in 41% of all cases. Sensitivity and specificity for FFDM vs SFM were 95.2 vs 91.9% and 41.4 vs 39.3%, respectively. Moreover, FFDM demonstrated a higher diagnostic accuracy (deviation: 0.86 BI-RADS steps) compared with FSM (deviation 0.93 BI-RADS steps). The FFDM system with a 100-mum pixel size provides better image quality than SFM in patients with mammographic microcalcifications. The FFDM has a higher sensitivity and a higher reliability in characterizing microcalcifications.
引用
收藏
页码:2679 / 2683
页数:5
相关论文
共 50 条
  • [1] Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography
    U. Fischer
    F. Baum
    S. Obenauer
    S. Luftner-Nagel
    D. von Heyden
    R. Vosshenrich
    E. Grabbe
    [J]. European Radiology, 2002, 12 : 2679 - 2683
  • [2] Screen-film mammography and soft-copy full-field digital mammography: Comparison in the patients with microcalcifications
    Kim, HS
    Han, BK
    Choo, KS
    Jeon, YH
    Kim, JH
    Choe, YH
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2005, 6 (04) : 214 - 220
  • [3] Full-field digital mammography in comparison to screen-film mammography - A phantom study
    Obenauer, S
    Schorn, C
    Funke, M
    Fischer, U
    Grabbe, E
    Hermann, KP
    [J]. IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 499 - 503
  • [4] Magnification mammography: a comparison of full-field digital mammography and screen-film mammography for the detection of simulated small masses and microcalcifications
    K.-P. Hermann
    S. Obenauer
    M. Funke
    E. Grabbe
    [J]. European Radiology, 2002, 12 : 2188 - 2191
  • [5] Magnification mammography: a comparison of full-field digital mammography and screen-film mammography for the detection of simulated small masses and microcalcifications
    Hermann, KP
    Obenauer, S
    Funke, M
    Grabbe, EH
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (09) : 2188 - 2191
  • [6] Comparison of the microcalcifications between full-field digital mammography and screen film mammography
    Tohno, E
    Kujiraoka, Y
    Watanabe, Y
    Itai, Y
    [J]. RADIOLOGY, 2001, 221 : 189 - 189
  • [7] Full-field digital mammography vs film-screen mammography in patients with microcalcifications: Comparison of detection and characterization
    Fischer, U
    Baum, FT
    Luftner-Nagel, S
    Obenauer, S
    Von Heyden, D
    Grabbe, EH
    [J]. RADIOLOGY, 2000, 217 : 201 - 201
  • [8] Breast mass classification on full-field digital mammography and screen-film mammography
    Shi, Jiazheng
    Sahiner, Berkman
    Chan, Heang-Ping
    Hadjiiski, Lubomir M.
    Ge, Jun
    Wei, Jun
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 371 - 377
  • [9] Clinical performance comparison of full-field digital mammography to screen-film mammography
    Berns, EA
    Hendrick, RE
    [J]. RADIOLOGY, 2001, 221 : 283 - 283
  • [10] Comparison of full-field digital and screen-film mammography dose
    Schueler, B.