Cone-beam Tomography from Short-Scan Circle-plus-Arc Data Measured on a C-arm System

被引:0
|
作者
Hoppe, Stefan [1 ]
Dennerlein, Frank [2 ]
Lauritsch, Guenter [3 ]
Hornegger, Joachim [1 ]
Noo, Frederic [2 ]
机构
[1] Univ Erlangen Nurnberg, Inst Pattern Recognit LME, Erlangen, Germany
[2] Univ Utah, Dept Radiol, Salt Lake City, UT USA
[3] Siemens AG, Med Solutions, Forchheim, Germany
基金
美国国家卫生研究院;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In C-arm computed tomography (CT) systems, the source trajectory does not follow an ideal trajectory. Thus, the real data acquisition geometry is typically expressed by a sequence of projection matrices. However, exact reconstruction algorithms are based on an analytic expression of the projection geometry. In this work, we present a reformulation of an exact reconstruction method to handle projection matrices. In particular, the M-line approach is investigated for a short-scan circle-plus-arc data acquisition. The computation of the derivative with respect to the source trajectory is numerically most critical for which a novel and stable implementation is developed. In order to determine the backprojection range, a 2D polygonal weighting scheme is proposed. Image results are presented from phantom data acquired by a Siemens AXIOM Artis C-arm system. Excellent image results are achieved. Due to the complete data acquisition, the problem of cone artifacts is totally resolved.
引用
收藏
页码:2873 / 2877
页数:5
相关论文
共 50 条
  • [1] A cone-beam reconstruction algorithm for circle-plus-arc data-acquisition geometry
    Wang, XH
    Ning, RL
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (09) : 815 - 824
  • [2] Cone-beam reconstruction algorithm for circle-plus-arc data-acquisition geometry
    Univ of Rochester, Rochester, United States
    IEEE Trans. Med. Imaging, 9 (815-824):
  • [3] Three-dimensional PSF characterization of circle-plus-arc cone-beam computed tomography
    Chen, ZK
    Ning, R
    Yu, Y
    Conover, D
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 664 - 675
  • [4] Accurate image reconstruction using real C-arm data from a Circle-plus-arc trajectory
    Hoppe, Stefan
    Hornegger, Joachim
    Dennerlein, Frank
    Lauritsch, Guenter
    Noo, Frederic
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (01) : 73 - 86
  • [5] Image reconstruction from cone-beam data on a circular short-scan
    Noo, F
    Heuscher, DJ
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 50 - 59
  • [6] Accurate image reconstruction using real C-arm data from a Circle-plus-arc trajectory
    Stefan Hoppe
    Joachim Hornegger
    Frank Dennerlein
    Günter Lauritsch
    Frédéric Noo
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 73 - 86
  • [7] Cone-beam reconstruction for a C-arm CT system
    Liu, X
    Defrise, M
    Desbat, L
    Fleute, M
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1489 - 1493
  • [8] Exact and efficient cone-beam reconstruction algorithm for a short-scan circle combined with various lines
    Dennerlein, F
    Katsevich, A
    Lauritsch, G
    Hornegger, J
    MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 388 - 399
  • [9] Respiratory correlated cone-beam computed tomography on an isocentric C-arm
    Kriminski, S
    Mitschke, M
    Sorensen, S
    Wink, NM
    Chow, PE
    Tenn, S
    Solberg, TD
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (22): : 5263 - 5280
  • [10] Time-resolved C-arm cone beam CT angiography (TR-CBCTA) imaging from a single short-scan C-arm cone beam CT acquisition with intra-arterial contrast injection
    Li, Yinsheng
    Garrett, John W.
    Li, Ke
    Wu, Yijing
    Johnson, Kevin
    Schafer, Sebastian
    Strother, Charles
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (07):