Cone-beam Tomography from Short-Scan Circle-plus-Arc Data Measured on a C-arm System

被引:0
|
作者
Hoppe, Stefan [1 ]
Dennerlein, Frank [2 ]
Lauritsch, Guenter [3 ]
Hornegger, Joachim [1 ]
Noo, Frederic [2 ]
机构
[1] Univ Erlangen Nurnberg, Inst Pattern Recognit LME, Erlangen, Germany
[2] Univ Utah, Dept Radiol, Salt Lake City, UT USA
[3] Siemens AG, Med Solutions, Forchheim, Germany
基金
美国国家卫生研究院;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In C-arm computed tomography (CT) systems, the source trajectory does not follow an ideal trajectory. Thus, the real data acquisition geometry is typically expressed by a sequence of projection matrices. However, exact reconstruction algorithms are based on an analytic expression of the projection geometry. In this work, we present a reformulation of an exact reconstruction method to handle projection matrices. In particular, the M-line approach is investigated for a short-scan circle-plus-arc data acquisition. The computation of the derivative with respect to the source trajectory is numerically most critical for which a novel and stable implementation is developed. In order to determine the backprojection range, a 2D polygonal weighting scheme is proposed. Image results are presented from phantom data acquired by a Siemens AXIOM Artis C-arm system. Excellent image results are achieved. Due to the complete data acquisition, the problem of cone artifacts is totally resolved.
引用
收藏
页码:2873 / 2877
页数:5
相关论文
共 50 条
  • [21] Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory
    Zhuang, Tingliang
    Zambelli, Joseph
    Nett, Brian
    Leng, Shuai
    Chen, Guang-Hong
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [22] Short-Scan Cone-Beam Dedicated Breast CT: Self-Supervised Denoising From Single Image
    Fu, Z.
    Tseng, H.
    Karellas, A.
    Vedantham, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E629 - E630
  • [24] Exact 3D cone-beam reconstruction from two short-scans using a C-arm imaging system
    Ramamurthi, K
    Strobel, N
    Prince, JL
    COMPUTATIONAL IMAGING III, 2005, 5674 : 87 - 98
  • [25] Survival Impact of C-Arm Cone-Beam Computed Tomography on Hepatocellular Carcinoma Patients Undergoing Chemoembolization
    Wallace, Michael J.
    Abdelsalam, Mohamed E.
    Ensor, Joseph E.
    Kaseb, Ahmed O.
    Tam, Alda
    Avritscher, Rony
    Gupta, Sanjay
    HEPATOLOGY, 2012, 56 : 466A - 467A
  • [26] C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules
    Chiara Floridi
    Alessandra Muollo
    Federico Fontana
    Nicola Rotolo
    Anna Maria Ierardi
    Ejona Duka
    Carlo Pellegrino
    Gianpaolo Carrafiello
    La radiologia medica, 2014, 119 : 820 - 827
  • [27] C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules
    Floridi, Chiara
    Muollo, Alessandra
    Fontana, Federico
    Rotolo, Nicola
    Ierardi, Anna Maria
    Duka, Ejona
    Pellegrino, Carlo
    Carrafiello, Gianpaolo
    RADIOLOGIA MEDICA, 2014, 119 (11): : 820 - 827
  • [28] Erratum to: C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications
    Chiara Floridi
    Alessandro Radaelli
    Nadine Abi-Jaoudeh
    Michael Grass
    MingDe Lin
    Melanie Chiaradia
    Jean-Francois Geschwind
    Hicham Kobeiter
    Ettore Squillaci
    Geert Maleux
    Andrea Giovagnoni
    Luca Brunese
    Bradford Wood
    Gianpaolo Carrafiello
    Antonio Rotondo
    La radiologia medica, 2015, 120 : 406 - 406
  • [29] Dual-rotation C-arm cone-beam computed tomography to increase low-contrast detection
    Reshef, Aymeric
    Riddell, Cyril
    Trousset, Yves
    Ladjal, Said
    Bloch, Isabelle
    MEDICAL PHYSICS, 2017, 44 (09) : E164 - E173
  • [30] Intraoperative C-arm cone-beam computed tomography: Quantitative analysis of surgical performance in skull base surgery
    Lee, Stella
    Gallia, Gary L.
    Reh, Douglas D.
    Schafer, Sebastian
    Uneri, Ali
    Mirota, Daniel J.
    Nithiananthan, Sajendra
    Otake, Yoshito
    Stayman, J. Webster
    Zbijewski, Wojciech
    Siewerdsen, Jeffrey H.
    LARYNGOSCOPE, 2012, 122 (09): : 1925 - 1932