Cone-beam Tomography from Short-Scan Circle-plus-Arc Data Measured on a C-arm System

被引:0
|
作者
Hoppe, Stefan [1 ]
Dennerlein, Frank [2 ]
Lauritsch, Guenter [3 ]
Hornegger, Joachim [1 ]
Noo, Frederic [2 ]
机构
[1] Univ Erlangen Nurnberg, Inst Pattern Recognit LME, Erlangen, Germany
[2] Univ Utah, Dept Radiol, Salt Lake City, UT USA
[3] Siemens AG, Med Solutions, Forchheim, Germany
基金
美国国家卫生研究院;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In C-arm computed tomography (CT) systems, the source trajectory does not follow an ideal trajectory. Thus, the real data acquisition geometry is typically expressed by a sequence of projection matrices. However, exact reconstruction algorithms are based on an analytic expression of the projection geometry. In this work, we present a reformulation of an exact reconstruction method to handle projection matrices. In particular, the M-line approach is investigated for a short-scan circle-plus-arc data acquisition. The computation of the derivative with respect to the source trajectory is numerically most critical for which a novel and stable implementation is developed. In order to determine the backprojection range, a 2D polygonal weighting scheme is proposed. Image results are presented from phantom data acquired by a Siemens AXIOM Artis C-arm system. Excellent image results are achieved. Due to the complete data acquisition, the problem of cone artifacts is totally resolved.
引用
收藏
页码:2873 / 2877
页数:5
相关论文
共 50 条
  • [41] Combined C-Arm Fluoroscopy and C-Arm Cone Beam Computed Tomography for the Evaluation of Patients With Possible Intrathecal Baclofen Delivery System Malfunctions COMMENTS
    Ojemann, Jeffrey G.
    Albright, A. Leland
    NEUROSURGERY, 2011, 69 : 33 - 33
  • [42] Calibration of Artis-Zeego C-arm cone beam computerized tomography angiography imaging system
    Li, Si
    Nunes, Jean-Claude
    Castro, Miguel
    Toumoulin, Christine
    Luo, Limin
    OPTICAL ENGINEERING, 2018, 57 (06)
  • [43] Compressed-sensing-based content-driven hierarchical reconstruction: Theory and application to C-arm cone-beam tomography
    Langet, Helene
    Riddell, Cyril
    Reshef, Aymeric
    Trousset, Yves
    Tenenhaus, Arthur
    Lahalle, Elisabeth
    Fleury, Gilles
    Paragios, Nikos
    MEDICAL PHYSICS, 2015, 42 (09) : 5222 - 5237
  • [44] Evaluation of three analytical methods for reconstruction from cone-beam data on a short circular scan
    Dennerlein, Frank
    Noo, Frederic
    Hoppe, Stefan
    Hornegger, Joachim
    Lauritsch, Guenter
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3933 - +
  • [45] Distribution of scatter radiation by C-arm cone-beam computed tomography in angiographic suite: measurement of doses and effectiveness of protection devices
    Yamaji, Mayako
    Ishiguchi, Tsuneo
    Koyama, Shuji
    Ikeda, Shuji
    Kitagawa, Akira
    Hagihara, Makiyo
    Itoh, Yuji
    Nakamura, Masaru
    Ota, Toyohiro
    Suzuki, Kojiro
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2021, 83 (02): : 277 - 286
  • [46] Usefulness of C-Arm Cone-Beam Computed Tomography in Endovascular Treatment of Traumatic Carotid Cavernous Fistulas: A Technical Case Report
    Sato, Kenichi
    Matsumoto, Yasushi
    Kondo, Ryushi
    Tominaga, Teiji
    NEUROSURGERY, 2010, 67 (02) : 467 - 469
  • [48] Effect of metal artifact reduction software on image quality of C-arm cone-beam computed tomography during intracranial aneurysm treatment
    Enomoto, Yukiko
    Yamauchi, Keita
    Asano, Takahiko
    Otani, Katharina
    Iwama, Toru
    INTERVENTIONAL NEURORADIOLOGY, 2018, 24 (03) : 303 - 308
  • [49] C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications (vol 119, pg 521, 2014)
    Floridi, Chiara
    Radaelli, Alessandro
    Abi-Jaoudeh, Nadine
    Grass, Michael
    Lin, MingDe
    Chiaradia, Melanie
    Geschwind, Jean-Francois
    Kobeiter, Hicham
    Squillaci, Ettore
    Maleux, Geert
    Giovagnoni, Andrea
    Brunese, Luca
    Wood, Bradford
    Carrafiello, Gianpaolo
    Rotondo, Antonio
    RADIOLOGIA MEDICA, 2015, 120 (04): : 406 - 406
  • [50] Learning Curve of C-Arm Cone-beam Computed Tomography Virtual. Navigation-Guided Percutaneous Transthoracic Needle Biopsy
    Ahn, Su Yeon
    Park, Chang Min
    Yoon, Soon Ho
    Kim, Hyungjin
    Goo, Jin Mo
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (05) : 844 - 853