Exact and efficient cone-beam reconstruction algorithm for a short-scan circle combined with various lines

被引:7
|
作者
Dennerlein, F [1 ]
Katsevich, A [1 ]
Lauritsch, G [1 ]
Hornegger, J [1 ]
机构
[1] Siemens Med Solut, D-91301 Frochheim, Germany
关键词
image reconstruction; computed tomography; cone-beam; theoretically exact; filtered backprojection algorithm; C-arm imaging; circle and line; data completeness; geometric calibration;
D O I
10.1117/12.595186
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
X-ray 3D rotational angiography based on C-arm systems has become a versatile and established tomographic imaging modality for high contrast objects in interventional environment. Improvements in data acquisition, e.g. by use of flat panel detectors, will enable C-arm systems to resolve even low-contrast details. However, further progress will be limited by the incompleteness of data acquisition on the conventional short-scan circular source trajectories. Cone artifacts, which result from that incompleteness, significantly degrade image quality by severe smearing and shading. To assure data completeness a combination of a partial circle with one or several line segments is investigated. A new and efficient reconstruction algorithm is deduced from a general inversion formula based on 3D Radon theory. The method is theoretically exact, possesses shift-invariant filtered backprojection (FBP) structure, and solves the long object problem. The algorithm is flexible in dealing with various circle and line configurations. The reconstruction method requires nothing more than the theoretically minimum length of scan trajectory. It consists of a conventional short-scan circle and a line segment approximately twice as long as the height of the region-of-interest. Geometrical deviations from the ideal source trajectory are considered in the implementation in order to handle data of real C-arm systems. Reconstruction results show excellent image quality free of cone artifacts. The proposed scan trajectory and reconstruction algorithm assure excellent image quality and allow low-contrast tomographic imaging with C-arm based cone-beam systems. The method can be implemented without any hardware modifications on systems commercially available today.
引用
收藏
页码:388 / 399
页数:12
相关论文
共 50 条
  • [1] A cone-beam FBP reconstruction algorithm for short-scan and super-short-scan source trajectories
    Zhuang, TL
    Nett, B
    Tang, XY
    Chen, GH
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 566 - 576
  • [2] A factorization approach for cone-beam reconstruction on a circular short-scan
    Dennerlein, Frank
    Noo, Frederic
    Schoendube, Harald
    Lauritsch, Guenter
    Hornegger, Joachim
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (07) : 887 - 896
  • [3] Image reconstruction from cone-beam data on a circular short-scan
    Noo, F
    Heuscher, DJ
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 50 - 59
  • [4] ECG gated circular cone-beam multi-cycle short-scan reconstruction algorithm
    van Stevendaal, Udo
    Koken, Peter
    Begemann, Philipp G. C.
    Koester, Ralf
    Adam, Gerhard
    Grass, Michael
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [5] The fan-beam short-scan FBP algorithm is not exact
    Zeng, G. L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08): : N131 - N139
  • [6] A short-scan reconstruction for cone-beam CT Using shift-invariant FBP and equal weighting
    Zhu, Lei
    Yoon, Sungwon
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2007, 34 (11) : 4422 - 4438
  • [7] A new super-short-scan algorithm for fan-beam and cone-beam reconstruction
    Li, LA
    Chen, ZQ
    Kang, KJ
    Zhao, ZR
    IMAGE RECONSTRUCTION FROM INCOMPLETE DATA III, 2004, 5562 : 80 - 87
  • [8] Cone-beam Tomography from Short-Scan Circle-plus-Arc Data Measured on a C-arm System
    Hoppe, Stefan
    Dennerlein, Frank
    Lauritsch, Guenter
    Hornegger, Joachim
    Noo, Frederic
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2873 - 2877
  • [9] Exact image reconstruction in a helical cone-beam scan with a variable pitch
    Zou, Y
    Pan, XC
    Xia, D
    Wang, G
    Jiang, TZ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4200 - 4203
  • [10] Cone-Beam Composite-Circling Scan and Exact Image Reconstruction for a Quasi-Short Object
    Yu, Hengyong
    Wang, Ge
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2007, 2007